Evaluation of mean glandular dose from mammography screening: A single-center study

被引:2
|
作者
Alahmad, Haitham [1 ,5 ]
AlEnazi, Khaled [1 ]
Alshahrani, Abdulrhman [2 ]
Albariqi, Saleh [3 ,4 ]
Alnafea, Mohammed [1 ]
机构
[1] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, Riyadh, Saudi Arabia
[2] Qassim Univ, Coll Appl Med Sci, Radiol Technol Dept, Buraydah, Saudi Arabia
[3] Alfaisal Univ, Coll Med, Dept Radiol & Imaging Sci, Riyadh, Saudi Arabia
[4] Prince Mohammed Bin Abdulaziz Hosp, Radiol Dept, Riyadh, Saudi Arabia
[5] King Saud Univ, Coll Appl Med Sci, Radiol Sci Dept, Riyadh 12372, Saudi Arabia
关键词
Breast cancer; Mammography; Mean glandular dose (MGD); Radiation dose; Compressed breast thickness (CBT); DIGITAL MAMMOGRAPHY; CANCER-RISKS; BREAST; WOMEN; RATES;
D O I
10.1016/j.jrras.2023.100749
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Breast cancer is one of the most common neoplasms among females in the developed world, and it is rapidly increasing in developing countries. X-ray mammography examination is the gold standard for early detection of breast cancer. However, such a procedure also increases the potential risk of radiation-induced carcinogenesis. Thus, assessment of the breast dose from mammography exposure is essential. The main objective of this study was to determine the Mean Glandular Dose (MGD) from craniocaudal (CC) views of mammography screening procedures in King Fahad Medical City (KFMC) hospital in Riyadh and to identify the factors affecting it. The calculations were performed to estimate MGD for 167 female patients who underwent mammography examinations in KFMC. Dance et al. (2000) calculation method was used to estimate the MGD. The selected patients' ages ranged from 30 to 85 years, and the range of their compressed breast thickness (CBT) was 2-8.6 cm. The average of the calculated MGD for the CC views for the selected patients was 1.17 +/- 0.54 mGy, which was significantly different from MGD values in other national studies. There was no correlation between MGD and age. CBT, kVp, and exposure time showed a moderate correlation with MGD. mAs and mA showed the strongest correlation with MGD. Including other mammography views such as mediolateral oblique (MLO), and estimating the cancer risk from mammography exposure should be explored in future studies.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] ASSESSMENT OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY
    FAULKNER, K
    LAW, J
    ROBSON, KJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (812): : 877 - 881
  • [2] Normalized mean glandular dose computation from mammography using GATE: a validation study
    Myronakis, Marios E.
    Zvelebil, Marketa
    Darambara, Dimitra G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2247 - 2265
  • [3] PORTUGUESE STUDY OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY AND COMPARISON WITH EUROPEAN REFERENCES
    dos Reis, Claudia Sa
    Fartaria, Mario Joao
    Garcia Alves, Joao H.
    Pascoal, Ana
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 179 (04) : 391 - 399
  • [4] Assessment of Mean Glandular Dose and Entrance Surface Dose in Mammography
    Abdallah, Yousif M.
    Abuhadi, Nouf H.
    Aldousari, Hanan A.
    [J]. JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (02): : 8 - 11
  • [5] CONFORMANCE OF MEAN GLANDULAR DOSE FROM PHANTOM AND PATIENT DATA IN MAMMOGRAPHY
    Kelaranta, A.
    Toroi, P.
    Timonen, M.
    Komssi, S.
    Kortesniemi, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 342 - 353
  • [6] A Monte Carlo model for mean glandular dose evaluation in spot compression mammography
    Sarno, Antonio
    Dance, David R.
    van Engen, Ruben E.
    Young, Kenneth C.
    Russo, Paolo
    Di Lillo, Francesca
    Mettivier, Giovanni
    Bliznakova, Kristina
    Fei, Baowei
    Sechopoulos, Ioannis
    [J]. MEDICAL PHYSICS, 2017, 44 (07) : 3848 - 3860
  • [7] Dosimetric evaluation of the mean glandular dose for mammography in Korean women: A preliminary report
    Oh, KK
    Hur, J
    Kim, EK
    Choo, SS
    [J]. YONSEI MEDICAL JOURNAL, 2003, 44 (05) : 863 - 868
  • [8] AN INVESTIGATION INTO VARIATIONS IN THE ESTIMATION OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY
    FAULKNER, K
    CRANLEY, K
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 405 - 407
  • [9] Investigation of Mean Glandular Dose in Diagnostic Mammography in China
    Du Xiang
    Wang Jin
    Yang Chun Yong
    Zhou Xian Feng
    Chen Wei
    Cao Xing Jiang
    Zhou Yuan Yuan
    Yu Ning Le
    [J]. BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2014, 27 (05) : 396 - 399
  • [10] Estimation of mean glandular dose for mammography of augmented breasts
    Beckett, JR
    Kotre, CJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3241 - 3252