Assessment of Mean Glandular Dose and Entrance Surface Dose in Mammography

被引:0
|
作者
Abdallah, Yousif M. [1 ]
Abuhadi, Nouf H. [2 ]
Aldousari, Hanan A. [3 ]
机构
[1] Majmaah Univ, Coll Appl Med Sci, Dept Radiol Sci & Med Imaging, Majmaah 11952, Saudi Arabia
[2] Jazan Univ, Coll Appl Med Sci, Dept Diagnost Radiol, Jazan, Saudi Arabia
[3] Jaber Alahmad Ctr Mol Imaging, Dept Med Phys, Kuwait, Kuwait
来源
关键词
Mean Glandular Dose; Entrance; Mammography; SYSTEM;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
X-ray diagnostic tests are important for public health. Such tests may involve significant patient irradiation and may be the population's largest radiation source. X-ray mammograms show different female lesions using ionizing radiation. The result is exposure to a small amount of increased radiation. This study was performed during mammograms to determine the average absorbed dose of x-rays and factors influencing the breast's median glandular dose (MGD). The study was conducted in Khartoum, Sudan, mammography patients. Sample size was 300 patients with different disease types. This study was in two Khartoum Hospitals. This study evaluated Robson's Mean Glandular Dose (MGD) and additional mammographic dance tests. Patient age, breast thickness, tube filter and exposure factors (mAs and kVp) were study parameters. Calculated MGD results show that patient exposure was significantly lower than standard IAEA dose. For Craniocaudal and Oblique projections, the average MGD values were 1.54 + 0.17 (p<.05) and 1.58 + 0.22 (p<0.05). This study documented patient characteristics and radiation exposure factors. For international agencies (IAEA, NCRP and ACR), these results should be less than the standard dose.
引用
收藏
页码:8 / 11
页数:4
相关论文
共 50 条
  • [1] ASSESSMENT OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY
    FAULKNER, K
    LAW, J
    ROBSON, KJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (812): : 877 - 881
  • [2] The Impact of Mammography Physics Instrumentation On Entrance Air Kerma and Mean Glandular Dose
    Brateman, L.
    Heintz, P.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Entrance skin exposure and mean glandular dose: Effect of scatter and field gradient at mammography
    Ng, KH
    Aus, RJ
    DeWerd, LA
    Vetter, JR
    [J]. RADIOLOGY, 1997, 205 (02) : 395 - 398
  • [4] Feasibility of determining Entrance Surface Dose (ESD) and mean glandular dose (MGD) using OSL signal from BeO dosimeters in mammography
    Aslar, Engin
    Sahiner, Eren
    Polymeris, George S.
    Meric, Niyazi
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 177
  • [5] AN INVESTIGATION INTO VARIATIONS IN THE ESTIMATION OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY
    FAULKNER, K
    CRANLEY, K
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 405 - 407
  • [6] Investigation of Mean Glandular Dose in Diagnostic Mammography in China
    Du Xiang
    Wang Jin
    Yang Chun Yong
    Zhou Xian Feng
    Chen Wei
    Cao Xing Jiang
    Zhou Yuan Yuan
    Yu Ning Le
    [J]. BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2014, 27 (05) : 396 - 399
  • [7] Estimation of mean glandular dose for mammography of augmented breasts
    Beckett, JR
    Kotre, CJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3241 - 3252
  • [8] A Methodology for Obtaining the Mean Glandular Dose in Mammography Exams
    Feital, J. C.
    Delgado, J. U.
    Lopes, R. T.
    [J]. VII BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2013), 2015, 575
  • [9] Investigation of Mean Glandular Dose in Diagnostic Mammography in China
    DU Xiang
    WANG Jin
    YANG Chun Yong
    ZHOU Xian Feng
    CHEN Wei
    CAO Xing Jiang
    ZHOU Yuan Yuan
    YU Ning Le
    [J]. Biomedical and Environmental Sciences, 2014, 27 (05) : 396 - 399
  • [10] Skin models and their impact on mean glandular dose in mammography
    Massera, Rodrigo Trevisan
    Tomal, Alessandra
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 51 : 38 - 47