PORTUGUESE STUDY OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY AND COMPARISON WITH EUROPEAN REFERENCES

被引:8
|
作者
dos Reis, Claudia Sa [1 ,2 ,3 ]
Fartaria, Mario Joao [3 ,4 ,5 ,6 ]
Garcia Alves, Joao H. [6 ,7 ]
Pascoal, Ana [3 ,8 ]
机构
[1] Curtin Univ, Dept Med Radiat Sci, Perth, WA, Australia
[2] Inst Politecn Lisboa ESTeSL IPL, Escola Super Tecnol Saude Lisboa, Lisbon, Portugal
[3] Univ Catolica Portuguesa, Fac Engn, Estr Octavio Pato, P-2635631 Rio De Mouro, Portugal
[4] CHU Vaudois, Dept Radiol, Lausanne, Switzerland
[5] Univ Lausanne UNIL, Lausanne, Switzerland
[6] Univ Lisbon, Inst Super Tecn, Lab Protecao & Seguranca Radiol, Estrada Nacl 10 Ao Km 139,7, P-2986066 Bobadela, Portugal
[7] UL, IST, C2TN, EN 10 Ao Km 139,7, P-2986066 Bobadela, Portugal
[8] Guys & St Thomas NHS Fdn Trust, London, England
关键词
BREAST SCREENING-PROGRAM; DIAGNOSTIC REFERENCE LEVELS; FIELD DIGITAL MAMMOGRAPHY; DOSIMETRY; UK; PROTOCOLS; DENSITY; PHANTOM; 6-YEAR;
D O I
10.1093/rpd/ncx300
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To characterise the mean glandular dose (MGD) in a sample of healthcare providers for digital mammography in Portugal. To compare the achieved values with European references. The MGD was measured on a poly-methyl-methacrylate phantom (45 mm) for each system using dosimeters. In addition, MGD was estimated using exposure settings collected from mammography exams in clinical context. Data were collected from 25 computed-radiography systems (CR) and 13 integrated digital (DR). For both measurements (phantom and clinical exposures), the average MGD for CR was higher compared to the DR. For CR the mean MGD was 1.85 mGy (CC projection) and 2.10 mGy (MLO projection). For DR systems the corresponding values were 1.54 mGy (CC) and 1.68 mGy (MLO). The average MGD obtained using both methods and for both technologies is within the acceptable reference range proposed by European guidelines (<2.5 mGy). Dose Reference Levels implementation should be the next step to optimise mammography practice in Portugal.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 50 条
  • [1] Mean glandular dose in digital mammography: A dose calculation method comparison
    [J]. Suleiman, Moayyad E. (msul1801@uni.sydney.edu.au), 1600, SPIE (04):
  • [2] ASSESSMENT OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY
    FAULKNER, K
    LAW, J
    ROBSON, KJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (812): : 877 - 881
  • [3] Assessment of Mean Glandular Dose and Entrance Surface Dose in Mammography
    Abdallah, Yousif M.
    Abuhadi, Nouf H.
    Aldousari, Hanan A.
    [J]. JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (02): : 8 - 11
  • [4] AN INVESTIGATION INTO VARIATIONS IN THE ESTIMATION OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY
    FAULKNER, K
    CRANLEY, K
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 405 - 407
  • [5] Estimation of mean glandular dose for mammography of augmented breasts
    Beckett, JR
    Kotre, CJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3241 - 3252
  • [6] Investigation of Mean Glandular Dose in Diagnostic Mammography in China
    Du Xiang
    Wang Jin
    Yang Chun Yong
    Zhou Xian Feng
    Chen Wei
    Cao Xing Jiang
    Zhou Yuan Yuan
    Yu Ning Le
    [J]. BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2014, 27 (05) : 396 - 399
  • [7] A Methodology for Obtaining the Mean Glandular Dose in Mammography Exams
    Feital, J. C.
    Delgado, J. U.
    Lopes, R. T.
    [J]. VII BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2013), 2015, 575
  • [8] Investigation of Mean Glandular Dose in Diagnostic Mammography in China
    DU Xiang
    WANG Jin
    YANG Chun Yong
    ZHOU Xian Feng
    CHEN Wei
    CAO Xing Jiang
    ZHOU Yuan Yuan
    YU Ning Le
    [J]. Biomedical and Environmental Sciences, 2014, 27 (05) : 396 - 399
  • [9] Skin models and their impact on mean glandular dose in mammography
    Massera, Rodrigo Trevisan
    Tomal, Alessandra
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 51 : 38 - 47
  • [10] A Study of Mean Glandular Dose during Diagnostic Mammography in Hospitals in Hanoi, Vietnam
    Nguyen Thai Ha
    Nguyen Duc Thuan
    Nguyen Thu Van
    [J]. THIRD INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM, 2010, 27 : 263 - 265