Image quality of thickened slabs in multislice CT chest examinations:: Postprocessing vs. direct reconstruction

被引:3
|
作者
Wedegaertner, U.
Yamamura, J.
Nagel, H.-D.
Aldefeld, D.
Brinkmann, C.
Popovych, S.
Buchert, R.
Weber, C.
Adam, G.
机构
[1] Univ Hamburg, Hosp Eppendorf, Klin & Poliklin Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Nukl Med Klin & Poliklin, D-20246 Hamburg, Germany
关键词
technical aspects; thorax; CT spiral;
D O I
10.1055/s-2006-927196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Postprocessing offers the possibility of real-time creation of thickened slabs from a set of thin slices. This allows the interactive change from thick to thin slices for better evaluation of unclear lesions. As a result the clinical workflow of MSCT evaluation can be improved. However, to be able to apply this postprocessing software in the clinical routine, degradations in the image quality (compared to standard original reconstructed images) have to be avoided. The purpose of this study was to compare the image quality of thickened slabs from MSCT chest examinations that have either been directly reconstructed from the raw data or have been retrospectively generated via postprocessing. Materials and Methods: Chest MSCT examinations of 20 patients (mean age: 56 years) were performed on a 16-slice MSCT scanner (Mx8000IDT16, Philips, Best, Netherlands) using the following scan parameters: 120 kV, 94 effective mAs, 16 x 1.5 mm collimation, 512 x 512 matrix, field of view 371 x 371 mm, CTDI-vol = 6.3 mGy, DLP = 210 mGyxcm). Slices with a thickness of 3 and 5 mm were generated for each examination both directly from the raw data and via postprocessing. Corresponding images from postprocessing and direct reconstruction (lung/ soft tissue window) were evaluated by two radiologists with respect to 5 criteria on the basis of a five-point scale: organ structure, contour of small objects, contrast, image noise and artifacts. Differences between both data sets regarding image quality were assessed for each of the 5 criteria using a Wilcoxon test with Bonferroni correction. In addition, image noise was analyzed quantitatively in a region of interest in the aorta. Results: For the lung and soft tissue window, both reviewers and all criteria, no differences in image quality were detected between the thickened slices obtained via direct reconstruction and the postprocessing method. In 96% and 95% of the cases images of the two reconstruction methods were graded identically for 3 mm and 5 mm slices. In the remaining 4% and 5%, the evaluations differed only by one point on the five-point scale. The median grade of the first reviewer was 1 and that of the second reviewer was 2. There were no differences in the quantitative analysis of image noise between both methods. Conclusion: The interactive creation of thickened slices is an effective tool for the evaluation of MSCT examinations. For the defined scan parameters in this study there were no differences in image quality between postprocessing methods (e.g. slab viewer) and direct image reconstruction.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [31] A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
    Leipsic, Jonathon
    Nguyen, Giang
    Brown, Jaqueline
    Sin, Don
    Mayo, John R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1095 - 1099
  • [32] The Value of Deep Learning Image Reconstruction in Improving the Quality of Low-Dose Chest CT Images
    Jiang, Jiu-Ming
    Miao, Lei
    Liang, Xin
    Liu, Zhuo-Heng
    Zhang, Li
    Li, Meng
    DIAGNOSTICS, 2022, 12 (10)
  • [33] Influence of Breast Reconstruction on Technical Difficulty of Echocardiographic Image Acquisition vs. Physician-Assessed Image Quality.
    Hemu, Mohamad R.
    Yakupovich, Anel
    Bhatt, Parva
    Gaddam, Hannah
    Okwuosa, Tochukwu M.
    Prabhu, Nicole
    Cobleigh, Melody
    Tracy, Melissa
    Fogg, Louis
    Fughhi, Ibtihaj A.
    Joaquin Duarte, Joaquin O.
    CIRCULATION, 2018, 138
  • [34] Imaging of the coronary arteries by means of multislice helical CT: Optimization of image quality with multisegmental reconstruction and variable gantry rotation time
    Lembcke, A
    Rogalla, P
    Mews, J
    Blobel, J
    Enzweiler, CNH
    Wiese, TH
    Hermann, KGA
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 780 - 785
  • [35] Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet
    Nam, H.
    Guo, M.
    Lee, K.
    Li, R.
    Xing, L.
    Gao, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 152 - +
  • [36] Commentary On: Image Quality Evaluation in Dual Energy CT of the Chest, Abdomen and Pelvis in Obese Patients with Deep Learning Image Reconstruction
    Jensen, Corey T.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (04) : 612 - 613
  • [37] Image Quality Evaluation in Dual-Energy CT of the Chest, Abdomen, and Pelvis in Obese Patients With Deep Learning Image Reconstruction
    Fair, Eric
    Profio, Mark
    Kulkarni, Naveen
    Laviolette, Peter S.
    Barnes, Bret
    Bobholz, Samuel
    Levenhagen, Maureen
    Ausman, Robin
    Griffin, Michael O.
    Duvnjak, Petar
    Zorn, Adam P.
    Foley, W. Dennis
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (04) : 604 - 611
  • [38] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Haesung Yoon
    Myung-Joon Kim
    Choon-Sik Yoon
    Jiin Choi
    Hyun Joo Shin
    Hyun Gi Kim
    Mi-Jung Lee
    Pediatric Radiology, 2015, 45 : 337 - 344
  • [39] Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT
    Barras, Heloise
    Dunet, Vincent
    Hachulla, Anne-Lise
    Grimm, Jochen
    Beigelman-Aubry, Catherine
    ACTA RADIOLOGICA OPEN, 2016, 5 (08)
  • [40] Evaluation of image quality and radiation dose by adaptive statistical iterative reconstruction technique level for chest CT examination
    Hong, Sun Suk
    Lee, Jong-Woong
    Seo, Jeong Beom
    Jung, Jae-Eun
    Choi, Jiwon
    Kweon, Dae Cheol
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (02) : 163 - 171