Image quality of thickened slabs in multislice CT chest examinations:: Postprocessing vs. direct reconstruction

被引:3
|
作者
Wedegaertner, U.
Yamamura, J.
Nagel, H.-D.
Aldefeld, D.
Brinkmann, C.
Popovych, S.
Buchert, R.
Weber, C.
Adam, G.
机构
[1] Univ Hamburg, Hosp Eppendorf, Klin & Poliklin Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Nukl Med Klin & Poliklin, D-20246 Hamburg, Germany
关键词
technical aspects; thorax; CT spiral;
D O I
10.1055/s-2006-927196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Postprocessing offers the possibility of real-time creation of thickened slabs from a set of thin slices. This allows the interactive change from thick to thin slices for better evaluation of unclear lesions. As a result the clinical workflow of MSCT evaluation can be improved. However, to be able to apply this postprocessing software in the clinical routine, degradations in the image quality (compared to standard original reconstructed images) have to be avoided. The purpose of this study was to compare the image quality of thickened slabs from MSCT chest examinations that have either been directly reconstructed from the raw data or have been retrospectively generated via postprocessing. Materials and Methods: Chest MSCT examinations of 20 patients (mean age: 56 years) were performed on a 16-slice MSCT scanner (Mx8000IDT16, Philips, Best, Netherlands) using the following scan parameters: 120 kV, 94 effective mAs, 16 x 1.5 mm collimation, 512 x 512 matrix, field of view 371 x 371 mm, CTDI-vol = 6.3 mGy, DLP = 210 mGyxcm). Slices with a thickness of 3 and 5 mm were generated for each examination both directly from the raw data and via postprocessing. Corresponding images from postprocessing and direct reconstruction (lung/ soft tissue window) were evaluated by two radiologists with respect to 5 criteria on the basis of a five-point scale: organ structure, contour of small objects, contrast, image noise and artifacts. Differences between both data sets regarding image quality were assessed for each of the 5 criteria using a Wilcoxon test with Bonferroni correction. In addition, image noise was analyzed quantitatively in a region of interest in the aorta. Results: For the lung and soft tissue window, both reviewers and all criteria, no differences in image quality were detected between the thickened slices obtained via direct reconstruction and the postprocessing method. In 96% and 95% of the cases images of the two reconstruction methods were graded identically for 3 mm and 5 mm slices. In the remaining 4% and 5%, the evaluations differed only by one point on the five-point scale. The median grade of the first reviewer was 1 and that of the second reviewer was 2. There were no differences in the quantitative analysis of image noise between both methods. Conclusion: The interactive creation of thickened slices is an effective tool for the evaluation of MSCT examinations. For the defined scan parameters in this study there were no differences in image quality between postprocessing methods (e.g. slab viewer) and direct image reconstruction.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [41] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Yoon, Haesung
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Choi, Jiin
    Shin, Hyun Joo
    Kim, Hyun Gi
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 337 - 344
  • [42] Deep Learning Vs. Iterative Reconstruction in CT Dose Reduction and Image Texture Preservation:A Live Animal Study
    Zhang, J.
    Raslau, F.
    Ganesh, H.
    Escott, E.
    Zhang, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [43] Image quality vs. sampling strategy for offset flat-panel cone-beam CT
    Hansis, Eberhard
    Sowards-Emmerd, David
    Bredno, Joerg
    Wang, Jiong
    Shao, Lingxiong
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [44] Split vs. Single Bolus CT Urography: Comparison of Scan Time, Image Quality and Radiation Dose
    Morrison, Nicole
    Bryden, Sherrie
    Costa, Andreu F.
    TOMOGRAPHY, 2021, 7 (02) : 210 - 218
  • [45] Improving the image quality of pediatric chest CT angiography with low radiation dose and contrast volume using deep learning image reconstruction
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Yu, Tong
    Li, Michelle
    Zhou, Zuofu
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (07) : 3051 - 3058
  • [46] Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities
    Lechuga, Lawrence
    Weidlich, Georg A.
    CUREUS, 2016, 8 (09):
  • [47] OS-EM reconstruction vs. filtered back projection (FBP) reconstruction for neurologic FDG PET studies: Improved image quality?
    Fulton, RR
    Meikle, SR
    Hooper, PK
    Eberl, S
    Silver, KM
    Fulham, MJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 872 - 872
  • [48] THE EFFECT OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION ON THE ASSESSMENT OF DIAGNOSTIC IMAGE QUALITY AND VISUALISATION OF ANATOMICAL STRUCTURES IN PAEDIATRIC CEREBRAL CT EXAMINATIONS
    Larsson, Joel
    Bath, Magnus
    Ledenius, Kerstin
    Thilander-Klang, Anne
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 115 - 122
  • [49] Correlation of clinical and physical-technical image quality in chest CT: a human cadaver study applied on iterative reconstruction
    De Crop, An
    Smeets, Peter
    Van Hoof, Tom
    Vergauwen, Merel
    Dewaele, Tom
    Van Borsel, Mathias
    Achten, Eric
    Verstraete, Koenraad
    D'Herde, Katharina
    Thierens, Hubert
    Bacher, Klaus
    BMC MEDICAL IMAGING, 2015, 15
  • [50] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    Lee, So Won
    Kim, Yookyung
    Shim, Sung Shine
    Lee, Jeong Kyong
    Lee, Seok Jeong
    Ryu, Yon Ju
    Chang, Jung Hyun
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 817 - 826