Image quality of thickened slabs in multislice CT chest examinations:: Postprocessing vs. direct reconstruction

被引:3
|
作者
Wedegaertner, U.
Yamamura, J.
Nagel, H.-D.
Aldefeld, D.
Brinkmann, C.
Popovych, S.
Buchert, R.
Weber, C.
Adam, G.
机构
[1] Univ Hamburg, Hosp Eppendorf, Klin & Poliklin Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Nukl Med Klin & Poliklin, D-20246 Hamburg, Germany
关键词
technical aspects; thorax; CT spiral;
D O I
10.1055/s-2006-927196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Postprocessing offers the possibility of real-time creation of thickened slabs from a set of thin slices. This allows the interactive change from thick to thin slices for better evaluation of unclear lesions. As a result the clinical workflow of MSCT evaluation can be improved. However, to be able to apply this postprocessing software in the clinical routine, degradations in the image quality (compared to standard original reconstructed images) have to be avoided. The purpose of this study was to compare the image quality of thickened slabs from MSCT chest examinations that have either been directly reconstructed from the raw data or have been retrospectively generated via postprocessing. Materials and Methods: Chest MSCT examinations of 20 patients (mean age: 56 years) were performed on a 16-slice MSCT scanner (Mx8000IDT16, Philips, Best, Netherlands) using the following scan parameters: 120 kV, 94 effective mAs, 16 x 1.5 mm collimation, 512 x 512 matrix, field of view 371 x 371 mm, CTDI-vol = 6.3 mGy, DLP = 210 mGyxcm). Slices with a thickness of 3 and 5 mm were generated for each examination both directly from the raw data and via postprocessing. Corresponding images from postprocessing and direct reconstruction (lung/ soft tissue window) were evaluated by two radiologists with respect to 5 criteria on the basis of a five-point scale: organ structure, contour of small objects, contrast, image noise and artifacts. Differences between both data sets regarding image quality were assessed for each of the 5 criteria using a Wilcoxon test with Bonferroni correction. In addition, image noise was analyzed quantitatively in a region of interest in the aorta. Results: For the lung and soft tissue window, both reviewers and all criteria, no differences in image quality were detected between the thickened slices obtained via direct reconstruction and the postprocessing method. In 96% and 95% of the cases images of the two reconstruction methods were graded identically for 3 mm and 5 mm slices. In the remaining 4% and 5%, the evaluations differed only by one point on the five-point scale. The median grade of the first reviewer was 1 and that of the second reviewer was 2. There were no differences in the quantitative analysis of image noise between both methods. Conclusion: The interactive creation of thickened slices is an effective tool for the evaluation of MSCT examinations. For the defined scan parameters in this study there were no differences in image quality between postprocessing methods (e.g. slab viewer) and direct image reconstruction.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [21] Patient radiation exposure and image quality evaluation with the use of iDose4 iterative reconstruction algorithm in chest-abdomen-pelvis CT examinations
    Ploussi, Agapi
    Alexopoulou, Efthymia
    Economopoulos, Nikolaos
    Argentos, Stylianos I.
    Tsitsia, Vasiliki
    Arapakis, Ioannis
    Kordolaimi, Sofia
    Seimenis, Ioannis
    Efstathopoulos, Efstathios P.
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (04) : 399 - 405
  • [22] Effects of contrast enhancement boost postprocessing technique in combination with different reconstruction algorithms on the image quality of abdominal CT angiography
    Xu, Jia
    Wang, Shitian
    Wang, Xuan
    Wang, Yun
    Xue, Huadan
    Yan, Jing
    Xu, Min
    Jin, Zhengyu
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 154
  • [23] Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality – preliminary findings
    Frédéric A. Miéville
    François Gudinchet
    Elena Rizzo
    Phalla Ou
    Francis Brunelle
    François O. Bochud
    Francis R. Verdun
    Pediatric Radiology, 2011, 41 : 1154 - 1164
  • [24] Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality - preliminary findings
    Mieville, Frederic A.
    Gudinchet, Francois
    Rizzo, Elena
    Ou, Phalla
    Brunelle, Francis
    Bochud, Francois O.
    Verdun, Francis R.
    PEDIATRIC RADIOLOGY, 2011, 41 (09) : 1154 - 1164
  • [25] Comparative assessment of three image reconstruction techniques for image quality and radiation dose in patients undergoing abdominopelvic multidetector CT examinations
    Desai, G. S.
    Thabet, A.
    Elias, A. Y. A.
    Sahani, D. V.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1021):
  • [26] Using "iDose4" iterative reconstruction algorithm in adults' chest-abdomen-pelvis CT examinations: effect on image quality in relation to patient radiation exposure
    Arapakis, I.
    Efstathopoulos, E.
    Tsitsia, V.
    Kordolaimi, S.
    Economopoulos, N.
    Argentos, S.
    Ploussi, A.
    Alexopoulou, E.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1036):
  • [27] Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Jin Seong
    Song, Jae-Woo
    Kim, Song Soo
    Lee, Hyun Joo
    Lim, Chae Hun
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 711 - 719
  • [28] Chest CT at a dose below 0.3 mSv: impact of iterative reconstruction on image quality and lung analysis
    Nakajo, Chiaki
    Heinzer, Susanne
    Montandon, Stephane
    Dunet, Vincent
    Bize, Pierre
    Feldman, Andrei
    Beigelman-Aubry, Catherine
    ACTA RADIOLOGICA, 2016, 57 (03) : 311 - 317
  • [29] Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image quality
    Macri, F.
    Greffier, J.
    Pereira, F. R.
    Mandoul, C.
    Khasanova, E.
    Gualdi, G.
    Beregi, J. P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (11) : 1131 - 1140
  • [30] Effect of iterative reconstruction techniques on image quality in low radiation dose chest CT: a phantom study
    Xu, Yan
    Zhang, Ting-ting
    Hu, Zhi-hai
    Li, Juan
    Hou, Hong-jun
    Xu, Zu-shan
    He, Wen
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (06) : 442 - 450