Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT

被引:16
|
作者
Hwang, Hye Jeon [1 ,2 ]
Seo, Joon Beom [1 ,2 ]
Lee, Jin Seong [1 ,2 ]
Song, Jae-Woo [1 ,2 ]
Kim, Song Soo [3 ]
Lee, Hyun Joo [1 ,2 ]
Lim, Chae Hun [1 ,2 ,4 ]
机构
[1] Univ Ulsan, Coll Med, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Res Inst Radiol, Asan Med Ctr, Seoul 138736, South Korea
[3] Chungnam Natl Univ, Sch Med, Chungnam Natl Univ Hosp, Dept Radiol, Taejon 301721, South Korea
[4] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Radiol, Seoul 137701, South Korea
关键词
Iterative reconstruction in image space; Chest CT; Radiation dose reduction; Image quality; COMPUTED-TOMOGRAPHY; EXPOSURE; THORAX;
D O I
10.3348/kjr.2012.13.6.711
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT. Materials and Methods: Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung. Results: Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP. Conclusion: IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.
引用
收藏
页码:711 / 719
页数:9
相关论文
共 50 条
  • [1] Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part II: Assessment of Radiologists' Preferences Using Dual Source CT
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Jin Seong
    Song, Jae-Woo
    Kim, Song Soo
    Lee, Hyun Joo
    Lim, Chae Hun
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 720 - 727
  • [2] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [3] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [4] Evaluating the effect of increased pitch, iterative reconstruction and dual source CT on dose reduction and image quality
    Gariani, Joanna
    Martin, Steve P.
    Botsikas, Diomidis
    Becker, Christoph D.
    Montet, Xavier
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1088):
  • [5] A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
    Leipsic, Jonathon
    Nguyen, Giang
    Brown, Jaqueline
    Sin, Don
    Mayo, John R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1095 - 1099
  • [6] Standard chest CT using combined automated tube potential selection and iterative reconstruction: image quality and radiation dose reduction
    Chae, In Hye
    Kim, Yookyung
    Lee, So Won
    Park, Ji Eun
    Shim, Sung Shine
    Lee, Jin Hwa
    CLINICAL IMAGING, 2014, 38 (05) : 641 - 647
  • [7] Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality
    Rivers-Bowerman, Michael D.
    Shankar, Jai Jai Shiva
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 620 - 625
  • [8] Objective assessment of image quality and dose reduction in CT iterative reconstruction
    Vaishnav, J. Y.
    Jung, W. C.
    Popescu, L. M.
    Zeng, R.
    Myers, K. J.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [9] Image quality and radiation dose reduction in chest CT in pulmonary infection
    Cristofaro, Massimo
    Rizzi, Elisa Busi
    Piselli, Pierluca
    Pianura, Elisa
    Petrone, Ada
    Fusco, Nicoletta
    Di Stefano, Federica
    Schinina', Vincenzo
    RADIOLOGIA MEDICA, 2020, 125 (05): : 451 - 460
  • [10] Image quality and radiation dose reduction in chest CT in pulmonary infection
    Massimo Cristofaro
    Elisa Busi Rizzi
    Pierluca Piselli
    Elisa Pianura
    Ada Petrone
    Nicoletta Fusco
    Federica Di Stefano
    Vincenzo Schinina’
    La radiologia medica, 2020, 125 : 451 - 460