Imaging of the coronary arteries by means of multislice helical CT: Optimization of image quality with multisegmental reconstruction and variable gantry rotation time

被引:0
|
作者
Lembcke, A
Rogalla, P
Mews, J
Blobel, J
Enzweiler, CNH
Wiese, TH
Hermann, KGA
Hamm, B
机构
[1] Humboldt Univ, Inst Radiol, Univ Klinikum Charite, D-10098 Berlin, Germany
[2] Toshiba Med Syst, Neuss, Germany
关键词
computed tomography (CT); heart; coronary vessels; SPIRAL COMPUTED-TOMOGRAPHY; MULTIDETECTOR-ROW CT; MOTION ARTIFACTS; HEART-RATE; ANGIOGRAPHY; STENOSES; VISUALIZATION; MULTIPLANAR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential of multisegmental reconstruction and variable gantry rotation time for reducing motion-induced artifacts in coronary artery imaging by multislice helical CT. Materials and Methods: The data sets of 20 patients (8 with HR < 60 bpm, 12 with HR > 60 bpm) were analyzed. The patients underwent multislice helical CT (Aquilion 8, Toshiba, Otawara, Japan) using the following parameters: 0.5 mm slice thickness, 250 mA, 120 W, pitch of 0.25 and variable gantry rotation times of 400, 500, or 600 msec. Images were generated by halfscan and multisegmental reconstruction. In 9 coronary segments of each patient, the presence and severity of motion artifacts were assessed and graded on a scale between 5 (no artifacts) and 1 (heaviest artifacts). Results: Diagnostically relevant motion artifacts were rare at low heart rates (< 60 bpm) for both types of image reconstruction (4% of all segments). Higher heart rates (> 60 bpm) were associated with an increase in motion artifacts on halfscan reconstructions (33% of all segments, p < 0.05) but not on multisegmental reconstructions (4% of all segments). At low heart rates mean image quality did not differ between multisegmental and halfscan reconstruction (4.28 +/- 0.37 vs. 4.22 +/- 0.41; p > 0.05), whereas at higher heart rates image quality was better for multisegmental reconstruction than for halfscan reconstruction (4.23 +/- 0.47 vs. 3.11 +/- 0.63; p < 0.05). Conclusion: Multisegmental reconstruction with variable gantry rotation times suppresses motion artifacts and thus improves assessment of the coronary arteries in patients with higher heart rates.
引用
收藏
页码:780 / 785
页数:6
相关论文
共 29 条
  • [1] Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time
    Hamoir, XL
    Flohr, T
    Hamoir, V
    Labaki, L
    Tricquet, JY
    Duhamel, A
    Kirsch, J
    EUROPEAN RADIOLOGY, 2005, 15 (02) : 296 - 304
  • [2] Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time
    Xavier L. Hamoir
    Thomas Flohr
    Vincent Hamoir
    Laurent Labaki
    Jean-Yves Tricquet
    Alain Duhamel
    Jacques Kirsch
    European Radiology, 2005, 15 : 296 - 304
  • [3] CT chest and gantry rotation time: does the rotation time influence image quality?
    Beeres, Martin
    Wichmann, Julian L.
    Paul, Jijo
    Mbalisike, Emmanuel
    Elsabaie, Mohamed
    Vogl, Thomas J.
    Nour-Eldin, Nour-Eldin A.
    ACTA RADIOLOGICA, 2015, 56 (08) : 950 - 954
  • [4] Evaluation of optimal match between gantry rotation time and cardiac cycle on multislice spiral CT coronary angiography imaging
    Xia, P.
    Xu, Q. -S.
    Hao, J. -M.
    Hu, C. -N.
    Wang, T.
    Zhao, B. -Z.
    Xia, Y. -S.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2014, 18 (23) : 3619 - 3628
  • [5] CT coronary angiography with 370 msec gantry rotation time: Evaluation of the best image reconstruction interval
    Bley, TA
    Ghanem, NA
    Pache, G
    Foell, D
    Saueressig, U
    Geibel, A
    Langer, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 66 - 66
  • [6] Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet
    Nam, H.
    Guo, M.
    Lee, K.
    Li, R.
    Xing, L.
    Gao, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 152 - +
  • [7] Assessment of coronary arteries and detection of severe lesions using the latest multislice detector computed tomography with 370 msec gantry rotation time
    Beck, T
    Kuettner, A
    Burgstahler, C
    Heuschmid, M
    Kopp, AF
    Drosch, T
    Claussen, CD
    Schroeder, S
    EUROPEAN HEART JOURNAL, 2004, 25 : 116 - 116
  • [8] Assessment of coronary arteries and detection of severe lesions using the latest multislice detector computed tomography with 370 msec gantry rotation time
    Beck, T
    Kuettner, A
    Burgstahler, C
    Kopp, A
    Schroeder, S
    CIRCULATION, 2004, 110 (17) : 447 - 447
  • [9] Does a combination of dose modulation with fast gantry rotation time limit CT image quality?
    Israel, Gary M.
    Herlihy, Summer
    Rubinowitz, Ami N.
    Cornfeld, Daniel
    Brink, James
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 140 - 144
  • [10] Influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting detector CT
    Feldle, Philipp
    Grunz, Jan-Peter
    Huflage, Henner
    Kunz, Andreas Steven
    Erguen, Sueleyman
    Afat, Saif
    Gruschwitz, Philipp
    Goertz, Lukas
    Pennig, Lenhard
    Bley, Thorsten Alexander
    Conrads, Nora
    SCIENTIFIC REPORTS, 2024, 14 (01):