Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time

被引:0
|
作者
Xavier L. Hamoir
Thomas Flohr
Vincent Hamoir
Laurent Labaki
Jean-Yves Tricquet
Alain Duhamel
Jacques Kirsch
机构
[1] Clinique Notre-dame,Department of Medical Imaging
[2] Siemens Medical Systems,Department of Cardiology
[3] Clinique Notre-dame,Department of Biostatistics, EA2694, Faculty of Medicine
[4] University of Lille,undefined
来源
European Radiology | 2005年 / 15卷
关键词
Multislice helical CT; Coronary artery; ECG gating;
D O I
暂无
中图分类号
学科分类号
摘要
Our objective was to evaluate the image quality of a 16-slice CT system with a rotation time of 375 ms in the assessment of coronary arteries. One hundred patients underwent iodine-enhanced CT coronary angiography within a single breath hold. Images were reconstructed in diastole, 300, 350, 400, 450, 500 and 550 ms prior to the onset of the next R-wave using absolute reverse retrospective ECG gating. The 15 coronary segments of the AHA classification were consensually reviewed by two radiologists. On the whole, best quality imaging was obtained with reconstruction intervals of −350 ms and −400 ms in high percentages of each segment (P<0.0001). Only 6.2% of the arteries with a diameter greater than or equal to 1.5 mm were not assessable because of extensive calcifications (3.9%), cardiac motion artifacts (1.9%), lack of enhancement (0.2%) and stent artifacts (0.3%). In patients with a heart rate above 70 beats per minute, the percentage of assessable segments decreased to 88%, while at a lower heart rate it increased to 95%. In 61% of the patients, all segments were assessable. In conclusion, this generation of CT technique may allow visualization of coronary arteries with a low percentage of non-assessable segments.
引用
收藏
页码:296 / 304
页数:8
相关论文
共 26 条
  • [1] Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time
    Hamoir, XL
    Flohr, T
    Hamoir, V
    Labaki, L
    Tricquet, JY
    Duhamel, A
    Kirsch, J
    EUROPEAN RADIOLOGY, 2005, 15 (02) : 296 - 304
  • [2] Imaging of the coronary arteries by means of multislice helical CT: Optimization of image quality with multisegmental reconstruction and variable gantry rotation time
    Lembcke, A
    Rogalla, P
    Mews, J
    Blobel, J
    Enzweiler, CNH
    Wiese, TH
    Hermann, KGA
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 780 - 785
  • [3] Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    Kopp, AF
    Schroeder, S
    Kuettner, A
    Heuschmid, M
    Georg, C
    Ohnesorge, B
    Kuzo, R
    Claussen, CD
    RADIOLOGY, 2001, 221 (03) : 683 - 688
  • [4] Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography
    Ko, Sung Min
    Kim, Na Ra
    Kim, Dong Hun
    Song, Meong Gun
    Kim, Jin Hwan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 93 - 101
  • [5] Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography
    Sung Min Ko
    Na Ra Kim
    Dong Hun Kim
    Meong Gun Song
    Jin Hwan Kim
    The International Journal of Cardiovascular Imaging, 2010, 26 : 93 - 101
  • [6] Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT
    Mahnken, AH
    Wildberger, JE
    Sinha, AM
    Dedden, K
    Stanzel, S
    Hoffmann, R
    Schmitz-Rode, T
    Günther, RW
    ACTA RADIOLOGICA, 2003, 44 (03) : 302 - 309
  • [7] Analysis of the heart rate and its variation affecting image quality and optimized reconstruction window in retrospective ECG-gated coronary angiography using multidetector row CT
    Lee, SH
    Choi, BW
    Kim, HJ
    Jung, H
    Son, HK
    Kang, WS
    Yoo, SK
    Choe, KO
    Yoo, HS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 225 - 231
  • [8] ECG-gated 16-MDCT of the coronary arteries: Assessment of image quality and accuracy in detecting stenoses
    Heuschmid, M
    Kuettner, A
    Schroeder, S
    Trabold, T
    Feyer, A
    Seemann, MD
    Kuzo, R
    Claus, CD
    Kopp, AF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) : 1413 - 1419
  • [9] Coronary artery imaging by multislice, spiral computed tomography: A novel ECG-gated reconstruction technique for the improved image quality
    Furuhashi, S
    Sato, Y
    Inoue, F
    Imazeki, T
    Takahashi, M
    Kanmatsuse, K
    RADIOLOGY, 2002, 225 : 483 - 483
  • [10] The accuracy of multislice spiral computed tomography using a novel ECG-Gated image reconstruction method for the assessment of coronary artery stenosis
    Horie, T
    Sato, Y
    Kato, M
    Inoue, F
    Imazeki, T
    Yoshimura, A
    Matsumoto, N
    Takahashi, M
    Kanmatsuse, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 421A - 421A