Imaging of the coronary arteries by means of multislice helical CT: Optimization of image quality with multisegmental reconstruction and variable gantry rotation time

被引:0
|
作者
Lembcke, A
Rogalla, P
Mews, J
Blobel, J
Enzweiler, CNH
Wiese, TH
Hermann, KGA
Hamm, B
机构
[1] Humboldt Univ, Inst Radiol, Univ Klinikum Charite, D-10098 Berlin, Germany
[2] Toshiba Med Syst, Neuss, Germany
关键词
computed tomography (CT); heart; coronary vessels; SPIRAL COMPUTED-TOMOGRAPHY; MULTIDETECTOR-ROW CT; MOTION ARTIFACTS; HEART-RATE; ANGIOGRAPHY; STENOSES; VISUALIZATION; MULTIPLANAR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential of multisegmental reconstruction and variable gantry rotation time for reducing motion-induced artifacts in coronary artery imaging by multislice helical CT. Materials and Methods: The data sets of 20 patients (8 with HR < 60 bpm, 12 with HR > 60 bpm) were analyzed. The patients underwent multislice helical CT (Aquilion 8, Toshiba, Otawara, Japan) using the following parameters: 0.5 mm slice thickness, 250 mA, 120 W, pitch of 0.25 and variable gantry rotation times of 400, 500, or 600 msec. Images were generated by halfscan and multisegmental reconstruction. In 9 coronary segments of each patient, the presence and severity of motion artifacts were assessed and graded on a scale between 5 (no artifacts) and 1 (heaviest artifacts). Results: Diagnostically relevant motion artifacts were rare at low heart rates (< 60 bpm) for both types of image reconstruction (4% of all segments). Higher heart rates (> 60 bpm) were associated with an increase in motion artifacts on halfscan reconstructions (33% of all segments, p < 0.05) but not on multisegmental reconstructions (4% of all segments). At low heart rates mean image quality did not differ between multisegmental and halfscan reconstruction (4.28 +/- 0.37 vs. 4.22 +/- 0.41; p > 0.05), whereas at higher heart rates image quality was better for multisegmental reconstruction than for halfscan reconstruction (4.23 +/- 0.47 vs. 3.11 +/- 0.63; p < 0.05). Conclusion: Multisegmental reconstruction with variable gantry rotation times suppresses motion artifacts and thus improves assessment of the coronary arteries in patients with higher heart rates.
引用
收藏
页码:780 / 785
页数:6
相关论文
共 29 条
  • [21] Impact of increasing levels of adaptive statistical iterative reconstruction on image quality in oil-based postmortem CT angiography in coronary arteries
    Andrea Steuwe
    Judith Boeven
    Lena Cordes
    Stefano Draisci
    Johannes Boos
    Silke Grabherr
    Christine Bruguier
    Hannan Dalyanoglu
    Gerald Antoch
    Joel Aissa
    International Journal of Legal Medicine, 2021, 135 : 1869 - 1878
  • [22] Impact of increasing levels of adaptive statistical iterative reconstruction on image quality in oil-based postmortem CT angiography in coronary arteries
    Steuwe, Andrea
    Boeven, Judith
    Cordes, Lena
    Draisci, Stefano
    Boos, Johannes
    Grabherr, Silke
    Bruguier, Christine
    Dalyanoglu, Hannan
    Antoch, Gerald
    Aissa, Joel
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2021, 135 (05) : 1869 - 1878
  • [23] Photon- counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality
    Sartoretti, Thomas
    Mcdermott, Michael
    Mergen, Victor
    Euler, Andre
    Schmidt, Bernhard
    Jost, Gregor
    Wildberger, Joachim
    Alkadhi, Hatem
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1143):
  • [24] Retrospective Gating vs. Prospective Triggering for Noninvasive Coronary Angiography: Assessment of Image Quality and Radiation Dose Using a 256-Slice CT Scanner with 270 ms Gantry Rotation
    Law, Wei-Yip
    Yang, Ching-Ching
    Chen, Liang-Kuang
    Huang, Tzung-Chi
    Lu, Kun-Mu
    Wu, Tung-Hsin
    Mok, Greta S. P.
    ACADEMIC RADIOLOGY, 2011, 18 (01) : 31 - 39
  • [25] CT imaging using variable helical pitch scanning for lower extremity arterial disease: Reduced contrast medium dose, improved image quality and diagnostic accuracy
    Li, Xiao-shi
    Geng, Ji-Gang
    Zhu, Yin-Hu
    Liu, Li-Yao
    Qiao, Yan-Qiang
    Ma, Yong-Li
    Lu, Lu
    Song, Chang-Rui
    Qin, Yue
    Chen, Guo-Ping
    Xu, Min
    Wang, Ya-Rong
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [26] Radiation Dose and Image quality of coronary CT angiography performed with whole-heart coverage CT scanner with 0.25s rotation time in patients with irregular heart rhythm
    Yan, Cheng
    Liu, Jing
    Min, Ji
    Zhou, Heng
    Gu, Junying
    Zhou, Guofeng
    Chen, Caizhong
    Yang, Chun
    Zeng, Mengsu
    HELIYON, 2024, 10 (04)
  • [27] Efficacy of ECG-gated scanning and ECG-gated reconstruction in multislice helical CT with half-second scanning for improving image quality of the heart and lung parenchyma: Evaluation using a cardiac motion phantom
    Kobayashi, Y
    Tanaka, O
    Imai, N
    Itou, E
    Hiraoka, M
    Taguchi, K
    RADIOLOGY, 2000, 217 : 162 - 162
  • [28] CT imaging using variable helical pitch scanning for lower extremity arterial disease: Reduced contrast medium dose, improved image quality and diagnostic accuracy (vol 184, 111792, 2024)
    Li, Xiao-Shi
    Geng, Ji-Gang
    Zhu, Yin-Hu
    Liu, Li-Yao
    Qiao, Yan Qiang
    Ma, Yong-Li
    Lu, Lu
    Song, Chang-Rui
    Qin, Yue
    Chen, Guo-Ping
    Xu, Min
    Wang, Zi-rui
    Wang, Ya-Rong
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [29] Optimization of image quality and accuracy of low iodine concentration quantification as function of dose level and reconstruction algorithm for abdominal imaging using dual-source CT: A phantom study
    Dabli, Djamel
    Frandon, Julien
    Belaouni, Asmaa
    Akessoul, Philippe
    Addala, Takieddine
    Berny, Laure
    Beregi, Jean-Paul
    Greffer, Joel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 31 - 40