Photon- counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality

被引:28
|
作者
Sartoretti, Thomas [1 ,2 ,3 ]
Mcdermott, Michael [2 ,3 ,4 ]
Mergen, Victor [1 ]
Euler, Andre [1 ]
Schmidt, Bernhard [5 ]
Jost, Gregor [4 ]
Wildberger, Joachim [2 ,3 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[3] Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[4] Bayer AG, Berlin, Germany
[5] Siemens Healthineers, Forchheim, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1143期
关键词
Computed Tomography Angiography; Coronary Vessels; Photons; Phantoms; Imaging; COMPUTED-TOMOGRAPHY; CONTRAST-MEDIA; STENOSIS; PHANTOM;
D O I
10.1259/bjr.20220466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA).Methods: CCTA with PCD- CT (prospective ECG -triggering, 120 kVp, automatic tube current modulation) was performed in a high -end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR- off) and with all quantum iterative reconstruction (QIR) levels (QIR- 1 to 4). In the phantom, noise power spectrum, vessel atten-uation, contrast - to-noise -ratio (CNR), and vessel sharp-ness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronaryartery plaque delineation on 5 -point Likert scales in patients.Results: In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR- 4 to 40 keV QIR- off. Reconstructions at 40 keV QIR- 4 exhibited the highest CNR (46.1 +/- 1.8), vessel sharpness (425 +/- 42 increment HU/mm), and vessel atten-uation (1098 +/- 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR- 3 and QIR- 4 images received the best scores (p < 0.001).Conclusion: Forty keV VMI with QIR- 4 significantly improved image quality of CCTA with PCD- CT. Advances in knowledge: PCD- CT at 40 keV and QIR- 4 improves image quality of CCTA.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Image quality of photon-counting detector CT virtual monoenergetic and polyenergetic reconstructions for head and neck CT angiography
    Spampinato, Maria Vittoria
    Rodgers, Jeffrey
    McGill, Liam J.
    Schoepf, Uwe Joseph
    O'Doherty, Jim
    CLINICAL IMAGING, 2024, 108
  • [2] Nonenhanced Photon Counting CT of the Head Impact of the keV Level, Iterative Reconstruction and Calvaria on Image Quality in Monoenergetic Images
    Michael, Arwed Elias
    Schoenbeck, Denise
    Woeltjen, Matthias Michael
    Boriesosdick, Jan
    Kroeger, Jan Robert
    Moenninghoff, Christoph
    Horstmeier, Sebastian
    Niehoff, Julius Henning
    Kabbasch, Christoph
    Goertz, Lukas
    Borggrefe, Jan
    CLINICAL NEURORADIOLOGY, 2024, 34 (01) : 75 - 83
  • [3] Photon Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions
    Michael, Arwed Elias
    Boriesosdick, Jan
    Schoenbeck, Denise
    Lopez-Schmidt, Ingo
    Kroeger, Jan Robert
    Moenninghoff, Christoph
    Horstmeier, Sebastian
    Pennig, Lenhard
    Borggrefe, Jan
    Niehoff, Julius Henning
    DIAGNOSTICS, 2022, 12 (06)
  • [4] Photon Counting Detector CT-Based Virtual Noniodine Reconstruction Algorithm for In Vitro and In Vivo Coronary Artery Calcium Scoring: Impact of Virtual Monoenergetic and Quantum Iterative Reconstructions
    Fink, Nicola
    Zsarnoczay, Emese
    Schoepf, U. Joseph
    Griffith III, Joseph P. P.
    Wolf, Elias V.
    O'Doherty, Jim
    Suranyi, Pal
    Baruah, Dhiraj
    Kabakus, Ismail M.
    Ricke, Jens
    Varga-Szemes, Akos
    Emrich, Tilman
    INVESTIGATIVE RADIOLOGY, 2023, 58 (09) : 673 - 680
  • [5] Quantum Iterative Reconstruction for Abdominal Photon-counting Detector CT Improves Image Quality
    Sartoretti, Thomas
    Landsmann, Anna
    Nakhostin, Dominik
    Eberhard, Matthias
    Roeren, Christian
    Mergen, Victor
    Higashigaito, Kai
    Raupach, Rainer
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 303 (02)
  • [6] Nonenhanced Photon Counting CT of the HeadImpact of the keV Level, Iterative Reconstruction and Calvaria on Image Quality in Monoenergetic Images
    Arwed Elias Michael
    Denise Schoenbeck
    Matthias Michael Woeltjen
    Jan Boriesosdick
    Jan Robert Kroeger
    Christoph Moenninghoff
    Sebastian Horstmeier
    Julius Henning Niehoff
    Christoph Kabbasch
    Lukas Goertz
    Jan Borggrefe
    Clinical Neuroradiology, 2024, 34 : 75 - 83
  • [7] Quantum iterative reconstruction on a photon-counting detector CT improves the quality of hepatocellular carcinoma imaging
    Dirk Graafen
    Fabian Stoehr
    Moritz C. Halfmann
    Tilman Emrich
    Friedrich Foerster
    Yang Yang
    Christoph Düber
    Lukas Müller
    Roman Kloeckner
    Cancer Imaging, 23
  • [8] Quantum iterative reconstruction on a photon-counting detector CT improves the quality of hepatocellular carcinoma imaging
    Graafen, Dirk
    Stoehr, Fabian
    Halfmann, Moritz C. C.
    Emrich, Tilman
    Foerster, Friedrich
    Yang, Yang
    Dueber, Christoph
    Mueller, Lukas
    Kloeckner, Roman
    CANCER IMAGING, 2023, 23 (01)
  • [9] Ultra-high resolution coronary CT angiography on photon-counting detector CT: bi-centre study on the impact of quantum iterative reconstruction on image quality and accuracy of stenosis measurements
    Vecsey-Nagy, Milan
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    Tremamunno, Giuseppe
    Fink, Nicola
    Zsarnoczay, Emese
    Szilveszte, Balint
    Graafen, Dirk
    Halfmann, Moritz C.
    Vattay, Borbala
    Boussoussou, Melinda
    O'Doherty, Jim
    Suranyi, Pal Spruill
    Maurovich-Horvat, Pal
    Emrich, Tilman
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 176
  • [10] Photon-Counting Detector CT Virtual Monoenergetic Images in Cervical Trauma Imaging-Optimization of Dental Metal Artifacts and Image Quality
    Dillinger, Daniel
    Overhoff, Daniel
    Froelich, Matthias F.
    Kaatsch, Hanns L.
    Booz, Christian
    Hagen, Achim
    Vogl, Thomas J.
    Schoenberg, Stefan O.
    Waldeck, Stephan
    DIAGNOSTICS, 2024, 14 (06)