Photon- counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality

被引:28
|
作者
Sartoretti, Thomas [1 ,2 ,3 ]
Mcdermott, Michael [2 ,3 ,4 ]
Mergen, Victor [1 ]
Euler, Andre [1 ]
Schmidt, Bernhard [5 ]
Jost, Gregor [4 ]
Wildberger, Joachim [2 ,3 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[3] Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[4] Bayer AG, Berlin, Germany
[5] Siemens Healthineers, Forchheim, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1143期
关键词
Computed Tomography Angiography; Coronary Vessels; Photons; Phantoms; Imaging; COMPUTED-TOMOGRAPHY; CONTRAST-MEDIA; STENOSIS; PHANTOM;
D O I
10.1259/bjr.20220466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA).Methods: CCTA with PCD- CT (prospective ECG -triggering, 120 kVp, automatic tube current modulation) was performed in a high -end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR- off) and with all quantum iterative reconstruction (QIR) levels (QIR- 1 to 4). In the phantom, noise power spectrum, vessel atten-uation, contrast - to-noise -ratio (CNR), and vessel sharp-ness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronaryartery plaque delineation on 5 -point Likert scales in patients.Results: In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR- 4 to 40 keV QIR- off. Reconstructions at 40 keV QIR- 4 exhibited the highest CNR (46.1 +/- 1.8), vessel sharpness (425 +/- 42 increment HU/mm), and vessel atten-uation (1098 +/- 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR- 3 and QIR- 4 images received the best scores (p < 0.001).Conclusion: Forty keV VMI with QIR- 4 significantly improved image quality of CCTA with PCD- CT. Advances in knowledge: PCD- CT at 40 keV and QIR- 4 improves image quality of CCTA.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Photon-Counting Detector CT With Quantum Iterative Reconstruction Impact on Liver Lesion Detection and Radiation Dose Reduction
    Racine, Damien
    Mergen, Victor
    Viry, Anais
    Eberhard, Matthias
    Becce, Fabio
    Rotzinger, David C.
    Alkadhi, Hatem
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2023, 58 (04) : 245 - 252
  • [42] Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability
    Booz, Christian
    Bucolo, Giuseppe M.
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Lanzafame, Ludovica R. M.
    Yel, Ibrahim
    Alizadeh, Leona S.
    Gruenewald, Leon D.
    Koch, Vitali
    Martin, Simon S.
    Dimitrova, Mirela
    Goekduman, Aynur
    Vogl, Thomas J.
    Kaatsch, Hanns L.
    Overhoff, Daniel
    Waldeck, Stephan
    RADIOLOGIA MEDICA, 2024, 129 (11): : 1633 - 1643
  • [43] Influence of Threshold Calibration On CT Image Quality of a Photon-Counting Detector
    Rodesch, P.
    Richtsmeier, D.
    Zalavari, L.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E174 - E174
  • [44] The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography
    Tatsugami, F.
    Matsuki, M.
    Nakai, G.
    Inada, Y.
    Kanazawa, S.
    Takeda, Y.
    Morita, H.
    Takada, H.
    Yoshikawa, S.
    Fukumura, K.
    Narumi, Y.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : E378 - E382
  • [45] Impact of increasing levels of adaptive statistical iterative reconstruction on image quality in oil-based postmortem CT angiography in coronary arteries
    Steuwe, Andrea
    Boeven, Judith
    Cordes, Lena
    Draisci, Stefano
    Boos, Johannes
    Grabherr, Silke
    Bruguier, Christine
    Dalyanoglu, Hannan
    Antoch, Gerald
    Aissa, Joel
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2021, 135 (05) : 1869 - 1878
  • [46] Impact of increasing levels of adaptive statistical iterative reconstruction on image quality in oil-based postmortem CT angiography in coronary arteries
    Andrea Steuwe
    Judith Boeven
    Lena Cordes
    Stefano Draisci
    Johannes Boos
    Silke Grabherr
    Christine Bruguier
    Hannan Dalyanoglu
    Gerald Antoch
    Joel Aissa
    International Journal of Legal Medicine, 2021, 135 : 1869 - 1878
  • [47] Soft Reconstruction Kernels Improve HCC Imaging on a Photon-Counting Detector CT
    Graafen, D.
    Mueller, L.
    Halfmann, M. C.
    Stoehr, F.
    Foerster, F.
    Dueber, C.
    Yang, Y.
    Kloeckner, R.
    Emrich, T.
    ACADEMIC RADIOLOGY, 2023, 30 : S143 - S154
  • [48] Toward truly combined PET/CT imaging using PET detectors and photon counting CT with iterative reconstruction implementing physical detector response
    Thibaudeau, Christian
    Berard, Philippe
    Tetrault, Marc-Andre
    Leroux, Jean-Daniel
    Bergeron, Melanie
    Fontaine, Rejean
    Lecomte, Roger
    MEDICAL PHYSICS, 2012, 39 (09) : 5697 - 5707
  • [49] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [50] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 13