Photon- counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality

被引:28
|
作者
Sartoretti, Thomas [1 ,2 ,3 ]
Mcdermott, Michael [2 ,3 ,4 ]
Mergen, Victor [1 ]
Euler, Andre [1 ]
Schmidt, Bernhard [5 ]
Jost, Gregor [4 ]
Wildberger, Joachim [2 ,3 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[3] Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[4] Bayer AG, Berlin, Germany
[5] Siemens Healthineers, Forchheim, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1143期
关键词
Computed Tomography Angiography; Coronary Vessels; Photons; Phantoms; Imaging; COMPUTED-TOMOGRAPHY; CONTRAST-MEDIA; STENOSIS; PHANTOM;
D O I
10.1259/bjr.20220466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA).Methods: CCTA with PCD- CT (prospective ECG -triggering, 120 kVp, automatic tube current modulation) was performed in a high -end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR- off) and with all quantum iterative reconstruction (QIR) levels (QIR- 1 to 4). In the phantom, noise power spectrum, vessel atten-uation, contrast - to-noise -ratio (CNR), and vessel sharp-ness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronaryartery plaque delineation on 5 -point Likert scales in patients.Results: In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR- 4 to 40 keV QIR- off. Reconstructions at 40 keV QIR- 4 exhibited the highest CNR (46.1 +/- 1.8), vessel sharpness (425 +/- 42 increment HU/mm), and vessel atten-uation (1098 +/- 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR- 3 and QIR- 4 images received the best scores (p < 0.001).Conclusion: Forty keV VMI with QIR- 4 significantly improved image quality of CCTA with PCD- CT. Advances in knowledge: PCD- CT at 40 keV and QIR- 4 improves image quality of CCTA.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Improving image quality and diagnostic usability in photon-counting coronary CT angiography using a novel reconstruction algorithm
    Haag, Nina P.
    Niehoff, Julius H.
    Shahzadi, Iram
    Panknin, Christoph
    Wiemer, Marcus
    Kaese, Sven
    Gertz, Roman Johannes
    Pennig, Lenhard
    Platte, Ole Inuk
    Surov, Alexey
    Borggrefe, Jan
    Kroeger, Jan Robert
    EUROPEAN RADIOLOGY, 2025,
  • [22] Photon-Counting Detector CT Virtual Monoenergetic Images for Coronary Artery Stenosis Quantification: Phantom and In Vivo Evaluation
    Wolf, Elias V.
    Halfmann, Moritz C.
    Varga-Szemes, Akos
    Fink, Nicola
    Kloeckner, Roman
    Bockius, Stefanie
    Allmendinger, Thomas
    Hagenauer, Junia
    Koehler, Till
    Kreitner, Karl-Friedrich
    Schoepf, U. Joseph
    Muenzel, Thomas
    Dueber, Christoph
    Gori, Tommaso
    Yang, Yang
    Hell, Michaela M.
    Emrich, Tilman
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (03)
  • [23] Optimized Virtual Monoenergetic Image Generation Via Adversarial Learning in Multi-Energy and Photon Counting Detector CT
    Chang, S.
    Koons, E.
    Gong, H.
    McCollough, C. H.
    Leng, S.
    MEDICAL PHYSICS, 2024, 51 (09) : 6648 - 6648
  • [24] Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT Angiography
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 649 - 654
  • [25] Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT
    Cundari, Giulia
    Deilmann, Philipp
    Mergen, Victor
    Ciric, Kristina
    Eberhard, Matthias
    Jungblut, Lisa
    Alkadhi, Hatem
    Higashigaito, Kai
    ACADEMIC RADIOLOGY, 2024, 31 (01) : 212 - 220
  • [26] Pseudoenhancement in Cystic Renal Lesions - Impact of Virtual Monoenergetic Images of Photon-Counting Detector CT on Lesion Classification
    Schade, Katharina Alexandra
    Mergen, Victor
    Sartoretti, Thomas
    Alkadhi, Hatem
    Euler, Andre
    ACADEMIC RADIOLOGY, 2023, 30 : S305 - S313
  • [27] Influence of virtual monoenergetic reconstructions on coronary CT angiography-based fractional flow reserve with photon-counting detector CT: intra-individual comparison with energy-integrating detector CT
    Tremamunno, Giuseppe
    Pinos, Daniel
    Zsarnoczay, Emese
    Schoepf, U. Joseph
    Vecsey-Nagy, Milan
    Gnasso, Chiara
    Fink, Nicola
    Kravchenko, Dmitrij
    Hagar, Muhammad Taha
    Griffith, Joseph
    O'Doherty, Jim
    Laghi, Andrea
    Emrich, Tilman
    Varga-Szemes, Akos
    INSIGHTS INTO IMAGING, 2025, 16 (01):
  • [28] Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT Feasibility and Image Characterization
    Mergen, Victor
    Sartoretti, Thomas
    Baer-Beck, Matthias
    Schmidt, Bernhard
    Petersilka, Martin
    Wildberger, Joachim Ernst
    Euler, Andre
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 780 - 788
  • [29] Impact of photon counting detector spectral distortion on virtual non-contrast CT imaging
    Feng, Mang
    Ji, Xu
    Zhang, Ran
    Miller, Jessica R.
    Chen, Guang-Hong
    Li, Ke
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [30] Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT
    Mergen, Victor
    Racine, Damien
    Jungblut, Lisa
    Sartoretti, Thomas
    Bickel, Steven
    Monnin, Pascal
    Higashigaito, Kai
    Martini, Katharina
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 305 (01) : 106 - 114