Photon Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions

被引:20
|
作者
Michael, Arwed Elias [1 ]
Boriesosdick, Jan [1 ]
Schoenbeck, Denise [1 ]
Lopez-Schmidt, Ingo [1 ]
Kroeger, Jan Robert [1 ]
Moenninghoff, Christoph [1 ]
Horstmeier, Sebastian [1 ]
Pennig, Lenhard [2 ,3 ]
Borggrefe, Jan [1 ]
Niehoff, Julius Henning [1 ]
机构
[1] Ruhr Univ Bochum, Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, D-32429 Minden, Germany
[2] Univ Cologne, Inst Diagnost & Intervent Radiol, Fac Med, D-50923 Cologne, Germany
[3] Univ Cologne, Univ Hosp Cologne, D-50923 Cologne, Germany
关键词
computed tomography; photon counting detector; CT angiography of the head and neck; virtual monoenergetic reconstructions; KILOELECTRON-VOLT-SETTINGS; LAYER DETECTOR CT; OPTIMIZATION; PERFORMANCE; DIAGNOSIS;
D O I
10.3390/diagnostics12061306
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. Methods: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40-120 keV). Additionally, two radiologists rated the perceived image quality. Results: The mean CTDIvol used in the PCCT was 8.31 +/- 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60-65 keV was rated as best image quality. Conclusion: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Image quality of photon-counting detector CT virtual monoenergetic and polyenergetic reconstructions for head and neck CT angiography
    Spampinato, Maria Vittoria
    Rodgers, Jeffrey
    McGill, Liam J.
    Schoepf, Uwe Joseph
    O'Doherty, Jim
    CLINICAL IMAGING, 2024, 108
  • [2] Image-Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions of Unenhanced CT Scans of the Head: Initial Experiences with the First Photon-Counting CT Approved for Clinical Use
    Michael, Arwed Elias
    Boriesosdick, Jan
    Schoenbeck, Denise
    Woeltjen, Matthias Michael
    Saeed, Saher
    Kroeger, Jan Robert
    Horstmeier, Sebastian
    Lennartz, Simon
    Borggrefe, Jan
    Niehoff, Julius Henning
    DIAGNOSTICS, 2022, 12 (02)
  • [3] Virtual monoenergetic imaging in photon-counting CT of the head and neck
    Farhadi, Faraz
    Sahbaee, Pooyan
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Saboury, Babak
    Gutjahr, Ralf
    Biassou, Nadia M.
    Shah, Ritu
    Flohr, Thomas G.
    Samei, Ehsan
    Pritchard, William F.
    Malayeri, Ashkan A.
    Bluemke, David A.
    Jones, Elizabeth C.
    CLINICAL IMAGING, 2023, 102 : 109 - 115
  • [4] Image Quality Assessment of Photon Counting Computed Tomography Angiography of the Head and Neck
    Song, Jae W.
    Colfer, Michael
    Pasyar, Pouyan
    Kasner, Scott E.
    Cucchiara, Brett L.
    Saba, Luca
    Noel, Peter B.
    Woo, John H.
    STROKE, 2024, 55
  • [5] Comparison of virtual monoenergetic and polyenergetic images reconstructed from dual-layer detector CT angiography of the head and neck
    Neuhaus, Victor
    Hokamp, Nils Grosse
    Abdullayev, Nuran
    Maus, Volker
    Kabbasch, Christoph
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1102 - 1110
  • [6] Comparison of virtual monoenergetic and polyenergetic images reconstructed from dual-layer detector CT angiography of the head and neck
    Victor Neuhaus
    Nils Große Hokamp
    Nuran Abdullayev
    Volker Maus
    Christoph Kabbasch
    Anastasios Mpotsaris
    David Maintz
    Jan Borggrefe
    European Radiology, 2018, 28 : 1102 - 1110
  • [7] Photon- counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality
    Sartoretti, Thomas
    Mcdermott, Michael
    Mergen, Victor
    Euler, Andre
    Schmidt, Bernhard
    Jost, Gregor
    Wildberger, Joachim
    Alkadhi, Hatem
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1143):
  • [8] Improvement of Image Quality in Unenhanced Dual-Layer CT of the Head Using Virtual Monoenergetic Images Compared With Polyenergetic Single-Energy CT
    Neuhaus, Victor
    Abdullayev, Nuran
    Hokamp, Nils Grosse
    Pahn, Gregor
    Kabbasch, Christoph
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    INVESTIGATIVE RADIOLOGY, 2017, 52 (08) : 470 - 476
  • [9] Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography
    Chamberlin, Jordan H.
    Toth, Adrienn
    Hinen, Shaun
    O'Doherty, Jim
    Baruah, Dhiraj
    Maisuria, Dhruw
    Mcguire, Aaron
    Knight, Heather
    Schoepf, U. Joseph
    Munden, Reginald F.
    Kabakus, Ismail M.
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e63 - e69
  • [10] Nonenhanced Photon Counting CT of the Head Impact of the keV Level, Iterative Reconstruction and Calvaria on Image Quality in Monoenergetic Images
    Michael, Arwed Elias
    Schoenbeck, Denise
    Woeltjen, Matthias Michael
    Boriesosdick, Jan
    Kroeger, Jan Robert
    Moenninghoff, Christoph
    Horstmeier, Sebastian
    Niehoff, Julius Henning
    Kabbasch, Christoph
    Goertz, Lukas
    Borggrefe, Jan
    CLINICAL NEURORADIOLOGY, 2024, 34 (01) : 75 - 83