Photon Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions

被引:20
|
作者
Michael, Arwed Elias [1 ]
Boriesosdick, Jan [1 ]
Schoenbeck, Denise [1 ]
Lopez-Schmidt, Ingo [1 ]
Kroeger, Jan Robert [1 ]
Moenninghoff, Christoph [1 ]
Horstmeier, Sebastian [1 ]
Pennig, Lenhard [2 ,3 ]
Borggrefe, Jan [1 ]
Niehoff, Julius Henning [1 ]
机构
[1] Ruhr Univ Bochum, Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, D-32429 Minden, Germany
[2] Univ Cologne, Inst Diagnost & Intervent Radiol, Fac Med, D-50923 Cologne, Germany
[3] Univ Cologne, Univ Hosp Cologne, D-50923 Cologne, Germany
关键词
computed tomography; photon counting detector; CT angiography of the head and neck; virtual monoenergetic reconstructions; KILOELECTRON-VOLT-SETTINGS; LAYER DETECTOR CT; OPTIMIZATION; PERFORMANCE; DIAGNOSIS;
D O I
10.3390/diagnostics12061306
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. Methods: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40-120 keV). Additionally, two radiologists rated the perceived image quality. Results: The mean CTDIvol used in the PCCT was 8.31 +/- 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60-65 keV was rated as best image quality. Conclusion: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Impact of organ-specific dose reduction on the image quality of head and neck CT angiography
    Schimmoeller, L.
    Lanzman, R. S.
    Heusch, P.
    Dietrich, S.
    Miese, F.
    Aissa, J.
    Heusner, T. A.
    Antoch, G.
    Kroepil, P.
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1503 - 1509
  • [32] Photon Counting Detector CT-Based Virtual Noniodine Reconstruction Algorithm for In Vitro and In Vivo Coronary Artery Calcium Scoring: Impact of Virtual Monoenergetic and Quantum Iterative Reconstructions
    Fink, Nicola
    Zsarnoczay, Emese
    Schoepf, U. Joseph
    Griffith III, Joseph P. P.
    Wolf, Elias V.
    O'Doherty, Jim
    Suranyi, Pal
    Baruah, Dhiraj
    Kabakus, Ismail M.
    Ricke, Jens
    Varga-Szemes, Akos
    Emrich, Tilman
    INVESTIGATIVE RADIOLOGY, 2023, 58 (09) : 673 - 680
  • [33] Photon-Counting CT in the Head and Neck: Current Applications and Future Prospects
    Benson, John C.
    Campeau, Norbert G.
    Diehn, Felix E.
    Lane, John I.
    Leng, Shuai
    Moonis, Gul
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (08) : 1000 - 1005
  • [34] Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment
    Pourmorteza, A.
    Symons, R.
    Reich, D. S.
    Bagheri, M.
    Cork, T. E.
    Kappler, S.
    Ulzheimer, S.
    Bluemke, D. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) : 2257 - 2263
  • [35] Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography
    Zhang, Tianle
    Geng, Xue
    Li, Dongxue
    Xu, Yize
    Zhao, Yongxia
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (05)
  • [36] Image quality improvement in head and neck angiography based on dual-energy CT and deep learning
    He Zhang
    Lulu Zhang
    Juan Long
    He Zhang
    Xiaonan Sun
    Shuai Zhang
    Aiyun Sun
    Shenman Qiu
    Yankai Meng
    Tao Ding
    Chunfeng Hu
    Kai Xu
    BMC Medical Imaging, 25 (1)
  • [37] Image quality of photon counting and energy integrating chest CT-Prospective head-to-head comparison on same patients
    Schwartz, Fides R.
    Ria, Francesco
    McCabe, Cindy
    Zarei, Mojtaba
    Rajagopal, Jayasai
    Molvin, Lior
    Marin, Daniele
    O'Sullivan-Murphy, Bryan
    Kalisz, Kevin R.
    Tailor, Tina D.
    Washington, Lacey
    Henry, Travis
    Samei, Ehsan
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
  • [38] Impact of photon counting detector CT derived virtual monoenergetic images and iodine maps on the diagnosis of pleural empyema
    Jungblut, Lisa
    Abel, Frederik
    Nakhostin, Dominik
    Mergen, Viktor
    Sartoretti, Thomas
    Euler, Andre
    Frauenfelder, Thomas
    Martini, Katharina
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (02) : 84 - 90
  • [39] Delineation of the brachial plexus by contrast-enhanced photon-counting detector CT and virtual monoenergetic images
    Nakashima, Masahiro
    Kawai, Tatsuya
    Matsumoto, Kazuhisa
    Kawaguchi, Takatsune
    Kitera, Nobuo
    Watanabe, Seita
    Itoh, Toshihide
    Hiwatashi, Akio
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [40] UNet-based multi-organ segmentation in photon counting CT using virtual monoenergetic images
    Baek, Sumin
    Ye, Dong Hye
    Lee, Okkyun
    MEDICAL PHYSICS, 2024,