Evaluation of optimal match between gantry rotation time and cardiac cycle on multislice spiral CT coronary angiography imaging

被引:0
|
作者
Xia, P. [1 ]
Xu, Q. -S. [1 ]
Hao, J. -M. [1 ]
Hu, C. -N. [1 ]
Wang, T. [1 ]
Zhao, B. -Z. [1 ]
Xia, Y. -S. [1 ]
机构
[1] Cent Hosp, Dept Radiol, Xuzhou, Peoples R China
关键词
X-ray; Computed tomography; Coronary artery; Gantry rotation; Temporal resolution; Multisector reconstruction; Cardiac cycle; HEART-RATE; COMPUTED-TOMOGRAPHY; 64-SECTION CT; RECONSTRUCTION; MOTION; ARTERIES; QUALITY; VARIABILITY; ARTIFACTS;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: To evaluate the relationship between gantry rotation time, heart rate and image quality during multislice spiral CT coronary angiography (MSCTCA). PATIENTS AND METHODS: Data of 83 patients who underwent MSCTCA were reviewed. Based on the ratio between cardiac cycle and gantry rotation time, the patients were divided into two groups. Patients whose heart rates fell in the resonance frequency (the cardiac cycle / gantry rotational time ratio of 1.5, 2 or 2.5) +/- 2 bpm were classified as synchronous (25 cases), while the remaining 58 patients (included a subgroup of 34 cases in whom heart rates were the same as in synchronous group but who had a different gantry rotation time). comprised the asynchronous group. Image qualities were compared between both groups. RESULTS: In the synchronous group, most (199/287; 69.33%) images were poor. When gantry rotation time was changed in the subgroup of the asynchronous group, the majority (423/442 or 95.70%) of images improved. There was a significant difference (p < 0.001) in the image quality among these patients. In 58 patients from asynchronous group, 757 segments of coronary arteries were evaluated, and 716 segments were of best quality (716/757; 94.58%). CONCLUSIONS: When heart rate and gantry rotation time correlate and synchronous, the so-called frequency harmonics, coronary artery image quality is poor. However, by changing gantry rotation time to avoid the harmonic helps to improve the image quality on MSCTCA. Based on the patient's heart rate, appropriate gantry rotation time can be selected in order to avoid resonance and obtain high quality images.
引用
收藏
页码:3619 / 3628
页数:10
相关论文
共 24 条
  • [1] CT coronary angiography with 370 msec gantry rotation time: Evaluation of the best image reconstruction interval
    Bley, TA
    Ghanem, NA
    Pache, G
    Foell, D
    Saueressig, U
    Geibel, A
    Langer, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 66 - 66
  • [2] Imaging of the coronary arteries by means of multislice helical CT: Optimization of image quality with multisegmental reconstruction and variable gantry rotation time
    Lembcke, A
    Rogalla, P
    Mews, J
    Blobel, J
    Enzweiler, CNH
    Wiese, TH
    Hermann, KGA
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 780 - 785
  • [3] Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time
    Hamoir, XL
    Flohr, T
    Hamoir, V
    Labaki, L
    Tricquet, JY
    Duhamel, A
    Kirsch, J
    EUROPEAN RADIOLOGY, 2005, 15 (02) : 296 - 304
  • [4] Multislice CT angiography in cardiac imaging. Part II: clinical applications in coronary artery disease
    Sun, Z.
    Ng, K. H.
    SINGAPORE MEDICAL JOURNAL, 2010, 51 (04) : 282 - 289
  • [5] Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time
    Xavier L. Hamoir
    Thomas Flohr
    Vincent Hamoir
    Laurent Labaki
    Jean-Yves Tricquet
    Alain Duhamel
    Jacques Kirsch
    European Radiology, 2005, 15 : 296 - 304
  • [6] A comparison study between CT angiography with 64-multislice spiral computed tomography and selective X-ray coronary angiography
    Cheng, Luyang
    Jing, Shenhong
    Zhang, Yina
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (03) : 969 - 971
  • [7] The evaluation of the relationship between coronary sinus and coronary artery by using multislice spiral computed tomography and a comparison with conventional invasive angiography
    Wei, Yidong
    Hu, Dayi
    Sun, Yingxian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 122 : 59 - 59
  • [8] Importance of the heart rate in ultra-high-resolution coronary CT angiography with 0.35 s gantry rotation time
    Tsukasa Kojima
    Takashi Shirasaka
    Yuzo Yamasaki
    Masatoshi Kondo
    Hiroshi Hamasaki
    Ryoji Mikayama
    Yuki Sakai
    Toyoyuki Kato
    Akihiro Nishie
    Kousei Ishigami
    Hidetake Yabuuchi
    Japanese Journal of Radiology, 2022, 40 : 781 - 790
  • [9] Importance of the heart rate in ultra-high-resolution coronary CT angiography with 0.35 s gantry rotation time
    Kojima, Tsukasa
    Shirasaka, Takashi
    Yamasaki, Yuzo
    Kondo, Masatoshi
    Hamasaki, Hiroshi
    Mikayama, Ryoji
    Sakai, Yuki
    Kato, Toyoyuki
    Nishie, Akihiro
    Ishigami, Kousei
    Yabuuchi, Hidetake
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (08) : 781 - 790
  • [10] Computed tomography coronary angiography with 370-millisecond gantry rotation time - Evaluation of the best image reconstruction interval
    Bley, TA
    Ghanem, NA
    Foell, D
    Uhl, M
    Geibel, A
    Bode, C
    Langer, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) : 1 - 5