Evaluation of optimal match between gantry rotation time and cardiac cycle on multislice spiral CT coronary angiography imaging

被引:0
|
作者
Xia, P. [1 ]
Xu, Q. -S. [1 ]
Hao, J. -M. [1 ]
Hu, C. -N. [1 ]
Wang, T. [1 ]
Zhao, B. -Z. [1 ]
Xia, Y. -S. [1 ]
机构
[1] Cent Hosp, Dept Radiol, Xuzhou, Peoples R China
关键词
X-ray; Computed tomography; Coronary artery; Gantry rotation; Temporal resolution; Multisector reconstruction; Cardiac cycle; HEART-RATE; COMPUTED-TOMOGRAPHY; 64-SECTION CT; RECONSTRUCTION; MOTION; ARTERIES; QUALITY; VARIABILITY; ARTIFACTS;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: To evaluate the relationship between gantry rotation time, heart rate and image quality during multislice spiral CT coronary angiography (MSCTCA). PATIENTS AND METHODS: Data of 83 patients who underwent MSCTCA were reviewed. Based on the ratio between cardiac cycle and gantry rotation time, the patients were divided into two groups. Patients whose heart rates fell in the resonance frequency (the cardiac cycle / gantry rotational time ratio of 1.5, 2 or 2.5) +/- 2 bpm were classified as synchronous (25 cases), while the remaining 58 patients (included a subgroup of 34 cases in whom heart rates were the same as in synchronous group but who had a different gantry rotation time). comprised the asynchronous group. Image qualities were compared between both groups. RESULTS: In the synchronous group, most (199/287; 69.33%) images were poor. When gantry rotation time was changed in the subgroup of the asynchronous group, the majority (423/442 or 95.70%) of images improved. There was a significant difference (p < 0.001) in the image quality among these patients. In 58 patients from asynchronous group, 757 segments of coronary arteries were evaluated, and 716 segments were of best quality (716/757; 94.58%). CONCLUSIONS: When heart rate and gantry rotation time correlate and synchronous, the so-called frequency harmonics, coronary artery image quality is poor. However, by changing gantry rotation time to avoid the harmonic helps to improve the image quality on MSCTCA. Based on the patient's heart rate, appropriate gantry rotation time can be selected in order to avoid resonance and obtain high quality images.
引用
收藏
页码:3619 / 3628
页数:10
相关论文
共 24 条
  • [21] MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?
    Tomas Jurencak
    Jakub Turek
    Bastiaan L. J. H. Kietselaer
    Casper Mihl
    Madeleine Kok
    Vincent G. V. A. van Ommen
    Leen A. F. M. van Garsse
    Estelle C. Nijssen
    Joachim E. Wildberger
    Marco Das
    European Radiology, 2015, 25 : 1975 - 1983
  • [22] MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?
    Jurencak, Tomas
    Turek, Jakub
    Kietselaer, Bastiaan L. J. H.
    Mihl, Casper
    Kok, Madeleine
    van Ommen, Vincent G. V. A.
    van Garsse, Leen A. F. M.
    Nijssen, Estelle C.
    Wildberger, Joachim E.
    Das, Marco
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 1975 - 1983
  • [23] Comparative effectiveness of coronary CT angiography vs stress cardiac imaging in patients following hospital admission for chest pain work-up: The Prospective First Evaluation in Chest Pain (PERFECT) Trial
    Seth Uretsky
    Edgar Argulian
    Azhar Supariwala
    Shiv K. Agarwal
    Georges El-Hayek
    Patricia Chavez
    Hira Awan
    Ashadevi Jagarlamudi
    Siva P. Puppala
    Randy Cohen
    Alan Rozanski
    Journal of Nuclear Cardiology, 2017, 24 : 1267 - 1278
  • [24] Comparative effectiveness of coronary CT angiography vs stress cardiac imaging in patients following hospital admission for chest pain work-up: The Prospective First Evaluation in Chest Pain (PERFECT) Trial
    Uretsky, Seth
    Argulian, Edgar
    Supariwala, Azhar
    Agarwal, Shiv K.
    El-Hayek, Georges
    Chavez, Patricia
    Awan, Hira
    Jagarlamudi, Ashadevi
    Puppala, Siva P.
    Cohen, Randy
    Rozanski, Alan
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1267 - 1278