Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study

被引:4
|
作者
Teimouri, Mehdi [1 ]
Ravanbod, Hadi [2 ]
Farrokhzad, Amirhosein [1 ]
Sabaghi, Jamal [1 ]
Mirghaderi, Seyed Peyman [3 ,4 ]
机构
[1] Isfahan Univ Med Sci, Ayatollah Kashani Hosp, Dept Orthoped Surg, Esfahan, Iran
[2] Isfahan Univ Med Sci, Al Zahra Hosp, Dept Orthoped Surg, Esfahan, Iran
[3] Univ Tehran Med Sci, Joint Reconstruct Res Ctr, Imam Khomeini Hosp Complex, Tehran, Iran
[4] Univ Tehran Med Sci, Students Sci Res Ctr SSRC, Tehran, Iran
关键词
Bone plates; Clavicle; Distal clavicle fracture; Hook plate; Internal fixators; T-plate; SURGICAL-TREATMENT; INTERNAL-FIXATION; UNSTABLE FRACTURES; LOCKING; OSTEOSYNTHESIS; 3RD;
D O I
10.1186/s13018-022-03261-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background This study aimed to compare the clinical and radiological outcomes of distal clavicle fracture fixation with a hook plate versus the standard non-locking T-plate for unstable Neer type II fractures. Methods A prospective matched cohort study including two groups of hook plates and T-plates fixation was conducted in our two tertiary trauma centers. Patients with distal clavicle fractures Neer type II were assessed for union and the Constant-Murley score (CMS) at 1-, 3-, and 6-month follow-ups. Inadequate radiographic consolidation > 6 months after surgery was defined as non-union. Subscales of CMSpain, CMSactivities of daily living, CMSrange of motion (ROM), and CMSstrength were also compared between groups. According to recommendations, the implant was removed after union confirmation in the hook plate at a planned second surgery. Results Sixty consecutive patients were enrolled: 30 in the T-plate group and 30 in the hook plate group. CMS showed similar functional outcomes for T-plates and hook plates at all follow-ups (Month 6: 92.0 vs. 91.7, P = 0.45). However, on the month 1 follow-up, the T-plate group scored higher than the hook plate group for ROM and pain (CMSpain = 13.0 vs. 12.3, P = 0.03; CMSROM = 35.2 vs. 33.2, P = 0.002). Despite this, Pain, ROM, and other CMS domains were comparable between groups (P > 0.05). The mean time to union was 2.5 + 1.4 months for the T-plate group and 2.3 + 1.6 months for the hook plate group (P = 0.44). There was one fixation failure in each group and one periprosthetic fracture in the hook plate group (two revisions for the hook plates and one for T-plates, P = 1.00). Non-union and other complications were not observed. Conclusion Both surgical approaches resulted in full recovery and good function. However, in the hook plate group ROM and pain scores were lower at 1 month. Standard non-locking T-plates are a viable alternative to hook plates with low cost and promising outcomes for treating displaced distal clavicle fractures.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Hook plate fixation of Neer type II distal clavicle fractures results in satisfactory patient-reported outcomes but complications and revisions are high
    Beisemann, Nils
    Spiller, Yannik M.
    Schnetzke, Marc
    Gruetzner, Paul Alfred
    Nolte, Philip-Christian
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [42] Hook plate fixation of Neer type II distal clavicle fractures results in satisfactory patient-reported outcomes but complications and revisions are high
    Nils Beisemann
    Yannik M. Spiller
    Marc Schnetzke
    Paul Alfred Grützner
    Philip-Christian Nolte
    BMC Musculoskeletal Disorders, 24
  • [43] Surgical treatment of unstable fractures of the distal clavicle -: A comparative study of Kirschner wire and clavicular hook plate fixation
    Flinkkilä, T
    Ristiniemi, J
    Hyvönen, P
    Hämäläinen, M
    ACTA ORTHOPAEDICA SCANDINAVICA, 2002, 73 (01): : 50 - 53
  • [44] Hook Plate fixation for type II fractures of the lateral end of the clavicle
    Haidar, Saadallah George
    Krishnan, Kamalakannan Murali
    Deshmukh, Subodh Chandrakant
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) : 419 - 423
  • [45] Comparison of the efficacy of a distal clavicular locking plate with and without a suture anchor in the treatment of Neer IIb distal clavicle fractures
    Hua Xu
    Wen Jun Chen
    Xiao Cheng Zhi
    Shi Chang Chen
    BMC Musculoskeletal Disorders, 20
  • [46] Comparison of the efficacy of a distal clavicular locking plate with and without a suture anchor in the treatment of Neer IIb distal clavicle fractures
    Xu, Hua
    Chen, Wen Jun
    Zhi, Xiao Cheng
    Chen, Shi Chang
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01) : 503
  • [47] Use of the AO hook-plate for treatment of unstable fractures of the distal clavicle
    Muramatsu, K.
    Shigetomi, M.
    Matsunaga, T.
    Murata, Y.
    Taguchi, T.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (03) : 191 - 194
  • [48] Use of the AO hook-plate for treatment of unstable fractures of the distal clavicle
    K. Muramatsu
    M. Shigetomi
    T. Matsunaga
    Y. Murata
    T. Taguchi
    Archives of Orthopaedic and Trauma Surgery, 2007, 127 : 191 - 194
  • [49] Comparing the coracoclavicular loop technique with a hook plate for the treatment of distal clavicle fractures
    Hsu, Kuei-Hsiang
    Tzeng, Yun-Hsuan
    Chang, Ming-Chau
    Chiang, Chao-Ching
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (02) : 224 - 230
  • [50] Fractures of the distal clavicle: outcomes and complications of surgical treatment using the hook plate
    Morales Davila, J.
    Domingo Trepat, A.
    Rios Martin, M.
    Carreno Delgado, A.
    Ballesteros Betancourt, J.
    Garcia Elvira, R.
    Garcia Tarrino, R.
    Camacho, P.
    Zumbado, A.
    Prat Fabregat, S.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2013, 64 (03) : 333 - 340