Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study

被引:4
|
作者
Teimouri, Mehdi [1 ]
Ravanbod, Hadi [2 ]
Farrokhzad, Amirhosein [1 ]
Sabaghi, Jamal [1 ]
Mirghaderi, Seyed Peyman [3 ,4 ]
机构
[1] Isfahan Univ Med Sci, Ayatollah Kashani Hosp, Dept Orthoped Surg, Esfahan, Iran
[2] Isfahan Univ Med Sci, Al Zahra Hosp, Dept Orthoped Surg, Esfahan, Iran
[3] Univ Tehran Med Sci, Joint Reconstruct Res Ctr, Imam Khomeini Hosp Complex, Tehran, Iran
[4] Univ Tehran Med Sci, Students Sci Res Ctr SSRC, Tehran, Iran
关键词
Bone plates; Clavicle; Distal clavicle fracture; Hook plate; Internal fixators; T-plate; SURGICAL-TREATMENT; INTERNAL-FIXATION; UNSTABLE FRACTURES; LOCKING; OSTEOSYNTHESIS; 3RD;
D O I
10.1186/s13018-022-03261-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background This study aimed to compare the clinical and radiological outcomes of distal clavicle fracture fixation with a hook plate versus the standard non-locking T-plate for unstable Neer type II fractures. Methods A prospective matched cohort study including two groups of hook plates and T-plates fixation was conducted in our two tertiary trauma centers. Patients with distal clavicle fractures Neer type II were assessed for union and the Constant-Murley score (CMS) at 1-, 3-, and 6-month follow-ups. Inadequate radiographic consolidation > 6 months after surgery was defined as non-union. Subscales of CMSpain, CMSactivities of daily living, CMSrange of motion (ROM), and CMSstrength were also compared between groups. According to recommendations, the implant was removed after union confirmation in the hook plate at a planned second surgery. Results Sixty consecutive patients were enrolled: 30 in the T-plate group and 30 in the hook plate group. CMS showed similar functional outcomes for T-plates and hook plates at all follow-ups (Month 6: 92.0 vs. 91.7, P = 0.45). However, on the month 1 follow-up, the T-plate group scored higher than the hook plate group for ROM and pain (CMSpain = 13.0 vs. 12.3, P = 0.03; CMSROM = 35.2 vs. 33.2, P = 0.002). Despite this, Pain, ROM, and other CMS domains were comparable between groups (P > 0.05). The mean time to union was 2.5 + 1.4 months for the T-plate group and 2.3 + 1.6 months for the hook plate group (P = 0.44). There was one fixation failure in each group and one periprosthetic fracture in the hook plate group (two revisions for the hook plates and one for T-plates, P = 1.00). Non-union and other complications were not observed. Conclusion Both surgical approaches resulted in full recovery and good function. However, in the hook plate group ROM and pain scores were lower at 1 month. Standard non-locking T-plates are a viable alternative to hook plates with low cost and promising outcomes for treating displaced distal clavicle fractures.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Surgical treatment of Neer type II and type V lateral clavicular fractures: comparison of hook plate versus superior plate with lateral extension: a retrospective cohort study
    Yassine Ochen
    Herman Frima
    R. Marijn Houwert
    Marilyn Heng
    Mark van Heijl
    Egbert J. M. M. Verleisdonk
    Detlef van der Velde
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 989 - 997
  • [22] Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate
    Sukur, Erhan
    Ozturkmen, Yusuf
    Akman, Yunus Emre
    Gungor, Mustafa
    Acta Orthopaedica et Traumatologica Turcica, 2016, 50 (05) : 489 - 493
  • [23] Comparative clinical outcomes and radiological images of clavicle hook plate versus Scorpion Plate® for unstable distal clavicle fractures
    Takatori, Naoki
    Uchiyama, Yoshiyasu
    Shimpuku, Eiji
    Imai, Takeshi
    Watanabe, Masahiko
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2025, 30 (02) : 307 - 312
  • [24] Comparison of a novel hybrid hook locking plate fixation method with the conventional AO hook plate fixation method for Neer type V distal clavicle fractures
    Seo, Joongbae
    Heo, Kang
    Kim, Seong-Jun
    Kim, Jun-Kyom
    Ham, Hee-Jung
    Yoo, Jaesung
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (01) : 67 - 75
  • [25] Locking plate combined with titanium cable for Neer type II distal clavicle fractures
    Zhang, Fan
    Fu, Qiang
    Li, Yongchuan
    Lu, Nan
    Chen, Aimin
    Zhao, Liangyu
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [26] Locking plate combined with titanium cable for Neer type II distal clavicle fractures
    Fan Zhang
    Qiang Fu
    Yongchuan Li
    Nan Lu
    Aimin Chen
    Liangyu Zhao
    BMC Musculoskeletal Disorders, 22
  • [27] Comparison of Hook Plate and Tension Band Wire in the Treatment of Distal Clavicle Fractures
    Hsu, Tzu-Liang
    Hsu, Shao-Keh
    Chen, Hsueh-Ming
    Wang, Shih-Tien
    ORTHOPEDICS, 2010, 33 (12)
  • [28] Clavicle hook plate fixation for displaced lateral-third clavicle fractures (Neer type II): a functional outcome study
    Good, Daniel W.
    Lui, Darren F.
    Leonard, Michael
    Morris, Seamus
    McElwain, John P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (08) : 1045 - 1048
  • [29] Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures
    Dashuang Li
    Rui Qiao
    Na Yang
    Kun Zhang
    Yangjun Zhu
    Zhe Song
    Journal of Orthopaedic Surgery and Research, 17
  • [30] Comparison of the efficacy of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle
    Lee, Yih-Shiunn
    Lau, Ming-Jye
    Tseng, Ya-Chun
    Chen, Wen-Chiao
    Kao, Hsin-Yi
    Wei, Jyh-Ding
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) : 1401 - 1405