Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study

被引:4
|
作者
Teimouri, Mehdi [1 ]
Ravanbod, Hadi [2 ]
Farrokhzad, Amirhosein [1 ]
Sabaghi, Jamal [1 ]
Mirghaderi, Seyed Peyman [3 ,4 ]
机构
[1] Isfahan Univ Med Sci, Ayatollah Kashani Hosp, Dept Orthoped Surg, Esfahan, Iran
[2] Isfahan Univ Med Sci, Al Zahra Hosp, Dept Orthoped Surg, Esfahan, Iran
[3] Univ Tehran Med Sci, Joint Reconstruct Res Ctr, Imam Khomeini Hosp Complex, Tehran, Iran
[4] Univ Tehran Med Sci, Students Sci Res Ctr SSRC, Tehran, Iran
关键词
Bone plates; Clavicle; Distal clavicle fracture; Hook plate; Internal fixators; T-plate; SURGICAL-TREATMENT; INTERNAL-FIXATION; UNSTABLE FRACTURES; LOCKING; OSTEOSYNTHESIS; 3RD;
D O I
10.1186/s13018-022-03261-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background This study aimed to compare the clinical and radiological outcomes of distal clavicle fracture fixation with a hook plate versus the standard non-locking T-plate for unstable Neer type II fractures. Methods A prospective matched cohort study including two groups of hook plates and T-plates fixation was conducted in our two tertiary trauma centers. Patients with distal clavicle fractures Neer type II were assessed for union and the Constant-Murley score (CMS) at 1-, 3-, and 6-month follow-ups. Inadequate radiographic consolidation > 6 months after surgery was defined as non-union. Subscales of CMSpain, CMSactivities of daily living, CMSrange of motion (ROM), and CMSstrength were also compared between groups. According to recommendations, the implant was removed after union confirmation in the hook plate at a planned second surgery. Results Sixty consecutive patients were enrolled: 30 in the T-plate group and 30 in the hook plate group. CMS showed similar functional outcomes for T-plates and hook plates at all follow-ups (Month 6: 92.0 vs. 91.7, P = 0.45). However, on the month 1 follow-up, the T-plate group scored higher than the hook plate group for ROM and pain (CMSpain = 13.0 vs. 12.3, P = 0.03; CMSROM = 35.2 vs. 33.2, P = 0.002). Despite this, Pain, ROM, and other CMS domains were comparable between groups (P > 0.05). The mean time to union was 2.5 + 1.4 months for the T-plate group and 2.3 + 1.6 months for the hook plate group (P = 0.44). There was one fixation failure in each group and one periprosthetic fracture in the hook plate group (two revisions for the hook plates and one for T-plates, P = 1.00). Non-union and other complications were not observed. Conclusion Both surgical approaches resulted in full recovery and good function. However, in the hook plate group ROM and pain scores were lower at 1 month. Standard non-locking T-plates are a viable alternative to hook plates with low cost and promising outcomes for treating displaced distal clavicle fractures.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures
    Li, Dashuang
    Qiao, Rui
    Yang, Na
    Zhang, Kun
    Zhu, Yangjun
    Song, Zhe
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [32] Comparison of the efficacy of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle
    Yih-Shiunn Lee
    Ming-Jye Lau
    Ya-Chun Tseng
    Wen-Chiao Chen
    Hsin-Yi Kao
    Jyh-Ding Wei
    International Orthopaedics, 2009, 33 : 1401 - 1405
  • [33] The treatment of distal clavicle fracture with the hook plate of multiple hook angles - A prospective study
    Lou, Weigang
    Xu, Ding
    Li, Ming
    Chen, Jianming
    ASIAN JOURNAL OF SURGERY, 2022, 45 (02) : 812 - 813
  • [34] Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review
    Zhang, Chunlin
    Huang, Junwu
    Luo, Yi
    Sun, Hua
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1461 - 1468
  • [35] Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review
    Chunlin Zhang
    Junwu Huang
    Yi Luo
    Hua Sun
    International Orthopaedics, 2014, 38 : 1461 - 1468
  • [36] Clavicle hook plate fixation for distal-third clavicle fracture (Neer type II): comparison of clinical and radiologic outcomes between Neer types IIA and IIB
    Lee, Wonyong
    Choi, Chong-Hyuk
    Choi, Yun-Rak
    Lim, Kyung-Han
    Chun, Yong-Min
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (07) : 1210 - 1215
  • [37] Osteosynthesis of symptomatic nonunions of type II fractures of the distal clavicle using modified locking T-plate and bone grafting
    Kang, Ho-Jung
    Kim, Hyoung-Sik
    Kim, Sung-Jae
    Yoo, Je-Hyun
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (02): : E14 - E19
  • [38] Surgical treatment of distal clavicle fractures using the clavicular hook plate
    Kashii, Masafumi
    Inui, Hiroaki
    Yamamoto, Kouji
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) : 158 - 164
  • [39] Comparative analysis of arthroscopic-assisted Tight-rope technique and clavicular hook plate fixation in the treatment of Neer type IIB distal clavicle fractures
    Nie, Si
    Li, Hong-Bo
    Hua, Li
    Tang, Zhi-Ming
    Lan, Min
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [40] Comparative analysis of arthroscopic-assisted Tight-rope technique and clavicular hook plate fixation in the treatment of Neer type IIB distal clavicle fractures
    Si Nie
    Hong-Bo Li
    Li Hua
    Zhi-Ming Tang
    Min Lan
    BMC Musculoskeletal Disorders, 23