Comparison of four different immunoassays and a rapid isotope-dilution liquid chromatography-tandem mass spectrometry assay for serum folate

被引:2
|
作者
Jin, Lizi [1 ,2 ]
Lu, Youli [3 ,4 ,5 ]
Yi, Xilian [1 ,2 ]
Zhang, Meiwei [3 ,4 ,5 ]
Zhang, Jiangtao [1 ,2 ]
Zhou, Weiyan [1 ,2 ]
Zeng, Jie [1 ,2 ]
Zhang, Tianjiao [1 ,2 ]
Zhang, Chuanbao [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Beijing Hosp, Natl Ctr Clin Labs, Inst Geriatr Med,Natl Ctr Gerontol, Beijing, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, 1 Dahua Rd, Beijing 100730, Peoples R China
[3] Fudan Univ, Shanghai Xuhui Cent Hosp, Cent Lab, Zhongshan Xuhui Hosp, Shanghai, Peoples R China
[4] Shanghai Engn Res Ctr Phase & Clin Res & Qual Con, Shanghai, Peoples R China
[5] Shanghai Inst Clin Mass Spectrometry, Shanghai, Peoples R China
关键词
immunoassays; isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS; MS); method comparison; serum folate;
D O I
10.1515/cclm-2021-1283
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Accurate measurement of serum folate is essential for the diagnosis and management of various disorders. This study aims to investigate the between-method differences of four immunoassays and a rapid isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method. Methods Roche Cobas (USA), Abbott Alinity i2000 (USA), Beckman Coulter Access (USA), Mindray CL-6000i (China), and the ID-LC-MS/MS method were compared using 46 human serum samples. The results were analysed by Passing-Bablok regressions and Bland-Altman plots. A bias of 13.31% based on biological variation was used as the bias criterion. Results All the within-run and total coefficients of variation (CVs) met the specification. The folate concentrations determined by all the assays were significantly different (p=0.0028). All assays had correlation coefficients over 0.97 with each other. The 95% confidence intervals (CIs) for the slope seldom contained 1 and few 95% CIs for the intercept contained 0 in the regression equations. Compared to ID-LC-MS/MS, the biases of all assays ranged from -20.91 to 13.56 nmol/L, and the mean relative biases ranged from -9.85 to 40.33%. The predicted mean relative biases at the medical decision levels rarely met the criterion. Conclusions Assays for serum folate had good correlations with each other but lacked good agreement. The accuracy and consistency of assays for serum folate should be measured and assessed routinely. Standardization work to improve the accuracy of serum folate assays, such as the extension of traceability to reference methods or materials, calibration standardization efforts, and assay-adjusted cut-offs should be promoted.
引用
收藏
页码:1393 / 1402
页数:10
相关论文
共 50 条
  • [21] Determination of bisphenol A, triclosan and their metabolites in human urine using isotope-dilution liquid chromatography-tandem mass spectrometry
    Provencher, Gilles
    Berube, Rene
    Dumas, Pierre
    Bienvenu, Jean-Francois
    Gaudreau, Eric
    Belanger, Patrick
    Ayotte, Pierre
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1348 : 97 - 104
  • [22] Pantothenic acid quantification by a stable isotope dilution assay based on liquid chromatography-tandem mass spectrometry
    Rychlik, M
    ANALYST, 2003, 128 (07) : 832 - 837
  • [23] Measurement of progesterone in human serum by isotope dilution liquid chromatography-tandem mass spectrometry and comparison with the commercial chemiluminescence immunoassay
    Lee, Hwashim
    Park, Chang Joon
    Lee, Gaeho
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (05) : 1713 - 1719
  • [24] Application of stable isotope dilution assays based on liquid chromatography-tandem mass spectrometry for the assessment of folate bioavailability
    Rychlik, M
    Netzel, M
    Pfannebecker, I
    Frank, T
    Bitsch, I
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 167 - 176
  • [25] Liquid Chromatography-Tandem Mass Spectrometry Analysis of Folate and Folate Catabolites in Human Serum
    Hannisdal, Rita
    Ueland, Per Magne
    Svardal, Asbjorn
    CLINICAL CHEMISTRY, 2009, 55 (06) : 1147 - 1154
  • [26] Quantification of key folate forms in serum using stable-isotope dilution ultra performance liquid chromatography-tandem mass spectrometry
    Kirsch, Susanne H.
    Knapp, Jean-Pierre
    Herrmann, Wolfgang
    Obeid, Rima
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (01): : 68 - 75
  • [27] Simultaneous measurement of amiodarone and desethylamiodarone in human plasma and serum by stable isotope dilution liquid chromatography-tandem mass spectrometry assay
    Kuhn, Joachim
    Goetting, Christian
    Kleesiek, Knut
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (01) : 210 - 216
  • [28] High accuracy analysis of glucose in human serum by isotope dilution liquid chromatography-tandem mass spectrometry
    Chen, Yizhao
    Liu, Qinde
    Yong, Sharon
    Lee, Tong Kooi
    CLINICA CHIMICA ACTA, 2012, 413 (7-8) : 808 - 813
  • [29] Measurement of dehydroepiandrosterone sulfate (DHEAS) in serum and cerebrospinal fluid by isotope-dilution liquid chromatography tandem mass spectrometry
    Buttler, Rahel M.
    Struys, Eduard A.
    Addie, Ruben
    Blankenstein, Marinus A.
    Heijboer, Annemieke C.
    CLINICA CHIMICA ACTA, 2012, 414 : 246 - 247
  • [30] Serum cholesterol measured by isotope dilution liquid chromatography tandem mass spectrometry
    Zhou, Weiyan
    Li, Hongxia
    Dong, Jun
    Wang, Shu
    Yang, Ruiyue
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (04) : 669 - 676