Comparison of four different immunoassays and a rapid isotope-dilution liquid chromatography-tandem mass spectrometry assay for serum folate

被引:2
|
作者
Jin, Lizi [1 ,2 ]
Lu, Youli [3 ,4 ,5 ]
Yi, Xilian [1 ,2 ]
Zhang, Meiwei [3 ,4 ,5 ]
Zhang, Jiangtao [1 ,2 ]
Zhou, Weiyan [1 ,2 ]
Zeng, Jie [1 ,2 ]
Zhang, Tianjiao [1 ,2 ]
Zhang, Chuanbao [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Beijing Hosp, Natl Ctr Clin Labs, Inst Geriatr Med,Natl Ctr Gerontol, Beijing, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, 1 Dahua Rd, Beijing 100730, Peoples R China
[3] Fudan Univ, Shanghai Xuhui Cent Hosp, Cent Lab, Zhongshan Xuhui Hosp, Shanghai, Peoples R China
[4] Shanghai Engn Res Ctr Phase & Clin Res & Qual Con, Shanghai, Peoples R China
[5] Shanghai Inst Clin Mass Spectrometry, Shanghai, Peoples R China
关键词
immunoassays; isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS; MS); method comparison; serum folate;
D O I
10.1515/cclm-2021-1283
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Accurate measurement of serum folate is essential for the diagnosis and management of various disorders. This study aims to investigate the between-method differences of four immunoassays and a rapid isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method. Methods Roche Cobas (USA), Abbott Alinity i2000 (USA), Beckman Coulter Access (USA), Mindray CL-6000i (China), and the ID-LC-MS/MS method were compared using 46 human serum samples. The results were analysed by Passing-Bablok regressions and Bland-Altman plots. A bias of 13.31% based on biological variation was used as the bias criterion. Results All the within-run and total coefficients of variation (CVs) met the specification. The folate concentrations determined by all the assays were significantly different (p=0.0028). All assays had correlation coefficients over 0.97 with each other. The 95% confidence intervals (CIs) for the slope seldom contained 1 and few 95% CIs for the intercept contained 0 in the regression equations. Compared to ID-LC-MS/MS, the biases of all assays ranged from -20.91 to 13.56 nmol/L, and the mean relative biases ranged from -9.85 to 40.33%. The predicted mean relative biases at the medical decision levels rarely met the criterion. Conclusions Assays for serum folate had good correlations with each other but lacked good agreement. The accuracy and consistency of assays for serum folate should be measured and assessed routinely. Standardization work to improve the accuracy of serum folate assays, such as the extension of traceability to reference methods or materials, calibration standardization efforts, and assay-adjusted cut-offs should be promoted.
引用
收藏
页码:1393 / 1402
页数:10
相关论文
共 50 条
  • [41] Development of a candidate reference method for determination of tyrosine in serum by isotope dilution liquid chromatography-tandem mass spectrometry
    Lee, Hwashim
    Park, Sangryoul
    Kim, Byungjoo
    Lee, Gaeho
    ANALYTICAL SCIENCES, 2007, 23 (03) : 299 - 303
  • [42] Development of a Candidate Reference Method for Determination of Tyrosine in Serum by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Hwashim Lee
    Sangryoul Park
    Byungjoo Kim
    Gaeho Lee
    Analytical Sciences, 2007, 23 : 299 - 303
  • [43] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Zhao, Haijian
    Zeng, Jie
    Zhang, Jiangtao
    Zhou, Weiyan
    Yan, Ying
    Wang, Yufei
    Wang, Mo
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7403 - 7411
  • [44] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Tianjiao Zhang
    Chuanbao Zhang
    Haijian Zhao
    Jie Zeng
    Jiangtao Zhang
    Weiyan Zhou
    Ying Yan
    Yufei Wang
    Mo Wang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7403 - 7411
  • [45] Stable Isotope Dilution Multidimensional Liquid Chromatography-Tandem Mass Spectrometry for Pancreatic Cancer Serum Biomarker Discovery
    Yu, Kenneth H.
    Barry, Colin G.
    Austin, David
    Busch, Christine M.
    Sangar, Vineet
    Rustgi, Anil K.
    Blair, Ian A.
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (03) : 1565 - 1576
  • [46] Accumulation of intact sulfur mustard in adipose tissue and toxicokinetics by chemical conversion and isotope-dilution liquid chromatography-tandem mass spectrometry
    Xu, Bin
    Zong, Cheng
    Zhang, Yajiao
    Zhang, Tianhong
    Wang, Xiaoying
    Qi, Meiling
    Wu, Jianfeng
    Guo, Lei
    Wang, Peng
    Chen, Jia
    Liu, Qin
    Xu, Hua
    Xie, Jianwei
    Zhang, Zhenqing
    ARCHIVES OF TOXICOLOGY, 2017, 91 (02) : 735 - 747
  • [47] Sensitive Quantification of Nicotine in Bronchoalveolar Lavage Fluid by Acetone Precipitation Combined With Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Xia, Baoyun
    Blount, Benjamin C.
    Wang, Lanqing
    ACS OMEGA, 2021, 6 (22): : 13962 - 13969
  • [48] Comparison of Automated 25-OH Vitamin D Immunoassays with Liquid Chromatography Isotope Dilution Tandem Mass Spectrometry
    Koivula, Marja-Kaisa
    Turpeinen, Ursula
    Laitinen, Paivi
    Risteli, Juha
    CLINICAL LABORATORY, 2012, 58 (11-12) : 1253 - 1261
  • [49] Quantification of urinary malondialdehyde by isotope-dilution liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction
    Hu, C. W.
    Huang, Y. J.
    Liu, H. H.
    Chao, M. R.
    CLINICAL BIOCHEMISTRY, 2011, 44 (13) : 1172 - 1172
  • [50] Development and evaluation of a reference measurement procedure for the determination of estradiol-17β in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    Tai, SSC
    Welsh, MJ
    ANALYTICAL CHEMISTRY, 2005, 77 (19) : 6359 - 6363