Liquid Chromatography-Tandem Mass Spectrometry Analysis of Folate and Folate Catabolites in Human Serum

被引:68
|
作者
Hannisdal, Rita [1 ,2 ]
Ueland, Per Magne [1 ,2 ,3 ]
Svardal, Asbjorn [1 ,2 ]
机构
[1] Univ Bergen, Inst Med, Pharmacol Sect, N-5021 Bergen, Norway
[2] Univ Bergen, LOCUS Homocysteine & Related Vitamins, N-5021 Bergen, Norway
[3] Haukeland Hosp, N-5021 Bergen, Norway
关键词
FOLIC-ACID SUPPLEMENTATION; NEURAL-TUBE DEFECTS; WHOLE-BLOOD FOLATE; 5-METHYLTETRAHYDROFOLIC ACID; HUMAN PLASMA; QUANTITATIVE-ANALYSIS; MICROBIOLOGIC ASSAY; DISEASE; HOMOCYSTEINE; URINE;
D O I
10.1373/clinchem.2008.114389
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Folate status is associated with several chronic diseases; thus accurate assessment of folate status has become important in the clinical setting and in epidemiological studies. The diversity of folate forms complicates the task of assaying endogenous folate. We developed and validated an assay that measures various forms of folate in addition to folate catabolites in human serum. METHODS: We added ascorbic acid to serum samples from 168 healthy blood donors and 39 patients with renal failure, and precipitated the proteins with acetonitrile containing C-13-labeled folate forms as internal standards. The supernatant was evaporated and the analytes redissolved in water. We then used liquid chromatography-tandem mass spectrometry to quantify 5-methyltetrahydrofolate (5mTHF), 4-alpha-hydroxy-5-methyltetrahydrofolate (hmTHF), folic acid (FA), 5-formyltrahydrofolate (5fTHF), p-aminobenzoylglutamate (pABG), and p-acetamidobenzoylglutamate (apABG). RESULTS: Detection limits were 0.07-0.52 nmol/L, and the assay was linear to 140 nmol/L for all analytes. The mean serum folate concentration from 168 blood donors was 22.7 nmol/L, of which 85.8% was 5mTHF, 12.1% hmTHF, 2.1% FA, and 0.0% 5fTHF. In the same individuals, the mean concentrations of pABG and apABG were 0.07 nmol/L and 0.47 nmol/L, respectively. The concentrations of folate catabolites were 22-30 times higher in 39 patients with renal failure. This folate assay correlated well with the microbiologic assay (r(2) = 0.92) and with measurement of serum folate as pABG equivalents (r(2) = 0.93). CONCLUSIONS: This method based on liquid chromatography-tandem mass spectrometry measures the most abundant folate species and 2 folate catabolites in human serum. (C) 2008 American Association for Clinical Chemistry
引用
收藏
页码:1147 / 1154
页数:8
相关论文
共 50 条
  • [1] Quantification of urinary folate catabolites using liquid chromatography-tandem mass spectrometry
    Niesser, Mareile
    Harder, Ulrike
    Koletzko, Berthold
    Peissner, Wolfgang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 929 : 116 - 124
  • [2] Simple method for the quantitative analysis of endogenous folate catabolites p-aminobenzoylglutamate (pABG) and its acetamido (apABG) derivative in human serum and urine by liquid chromatography-tandem mass spectrometry
    Sokoro, AAH
    Etter, ML
    Lepage, J
    Weist, B
    Eichhorst, J
    Lehotay, DC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (01): : 9 - 16
  • [3] Quantitative determination of erythrocyte folate vitamer distribution by liquid chromatography-tandem mass spectrometry
    Smith, DEC
    Kok, RM
    Teerlink, T
    Jakobs, C
    Smulders, YM
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (04) : 450 - 459
  • [4] Simultaneous quantification of homocysteine and folate in human serum or plasma using liquid chromatography/tandem mass spectrometry
    Nelson, BC
    Satterfield, MB
    Sniegoski, LT
    Welch, MJ
    ANALYTICAL CHEMISTRY, 2005, 77 (11) : 3586 - 3593
  • [5] Quantification of folate metabolites in serum using ultraperformance liquid chromatography tandem mass spectrometry
    Wang, Xiuwei
    Zhang, Ting
    Zhao, Xin
    Guan, Zhen
    Wang, Zhen
    Zhu, Zhiqiang
    Xie, Qiu
    Wang, Jianhua
    Niu, Bo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 962 : 9 - 13
  • [6] Determination of Lamotrigine in Human Serum By Liquid Chromatography-Tandem Mass Spectrometry
    Lee, W.
    Yoon, S.
    Park, Y.
    Suh, B.
    Kwon, O. H.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A261 - A261
  • [7] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [8] Determination of Tirofiban in human serum by liquid chromatography-tandem mass spectrometry
    Oertel, R
    Köhler, A
    Koster, A
    Kirch, W
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 181 - 185
  • [9] Quantification of folate in whole blood by liquid chromatography tandem mass spectrometry
    Huang, Yuehua
    Lu, Zhiyong
    Whitehead, A. Steven
    Blair, Ian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [10] Quantification of folate in whole blood by liquid chromatography tandem mass spectrometry
    Huang, Yuehua
    Lu, Zhiyong
    Whitehead, A. Steven
    Blair, Ian
    CHEMICAL RESEARCH IN TOXICOLOGY, 2007, 20 (12) : 2010 - 2010