The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials

被引:2
|
作者
Polychronakis, Nick [1 ]
Dimitriadi, Maria [2 ]
Polyzois, Gregory [1 ]
Eliades, George [2 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[2] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Biomat, Athens, Greece
关键词
Heat-cured denture base acrylics; Cooling procedures; Methyl methacrylate monomer elution; Ultra-fast liquid chromatography; RESIDUAL MONOMER; ACRYLIC RESIN; METHYL-METHACRYLATE; CYTOTOXICITY; RELEASE; WATER; LEVEL; TIME;
D O I
10.1590/1678-7757-2022-0161
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. Methodology: Disk-shaped specimens (empty set:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37 degrees C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student's and Welch's t-test (alpha=0.05). Results: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). Conclusions: The cooling procedures may affect the monomer elution from denture base materials. The E procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] TECHNIQUE FOR FABRICATION OF THE MANDIBULAR DENTURE OVER THE STAPLE BONE IMPLANT USING A PERMANENT HEAT-CURED BASE
    GOLL, GE
    SMITH, DE
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (06): : 820 - 824
  • [32] An in vitro study into the effect of a limited range of denture cleaners on surface roughness and removal of Candida albicans from conventional heat-cured acrylic resin denture base material
    Harrison, Z
    Johnson, A
    Douglas, CWI
    JOURNAL OF ORAL REHABILITATION, 2004, 31 (05) : 460 - 466
  • [33] Histocompatibility of novel cycloaliphatic comonomer in heat-cured denture base acrylic resin: Histomorphometric analysis in rats
    Ajay, Ranganathan
    Suma, Karthigeyan
    Arulkumar, Sengottaiyan
    Mahadevan, Ravichandran
    Ambedkar, Elumalai
    Biju, Katturkaran Antonisamy
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2020, 12 : 453 - 461
  • [34] The Impact of Adding Silanized Microcrystalline Cellulose on Some Properties of Heat-Cured Acrylic Denture Base Material
    Zaidan, Nareman Muhannad
    Jassim, Raghdaa Kareem
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (08): : 11 - +
  • [35] Biocompatibility of polymethyl methacrylate heat-polymerizing denture base resin copolymerized with antimicrobial monomers
    Rao, Sowmya
    Surya, Suprith
    Pavan, S. R.
    Ali, Saheb
    Prabhu, Ashwini
    Ginjupalli, Kishore
    Shenoy, Pooja Umesh
    Das, Ranajit
    Nandish, B. T.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03): : 644e1 - 644e10
  • [36] CHARACTERIZATION OF MULTIWALLED CARBON NANOTUBE-POLYMETHYL METHACRYLATE COMPOSITE RESINS AS DENTURE BASE MATERIALS
    Wang, Russell
    Tao, Junliang
    Yu, Bill
    Dai, Liming
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (04): : 318 - 326
  • [37] Effect of Negative Ion Powder on the Mechanical Properties of Polymethyl Methacrylate(PMMA) Denture Base
    Liu, Wen-Juan
    Zhang, Yu-Lin
    Zhang, Kang-Tai
    Ding, Li-Li
    Zheng, Ya-Wen
    Xie, Wei-Bo
    Dou, Fang-Yu
    Liu, Bin
    INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS ENGINEERING (ICMME 2014), 2014, : 344 - 348
  • [38] Impact of fabrication procedures on residual monomer elution of conventional polymethyl methacrylate (PMMA)-a measurement approach by UV/Vis spectrophotometry
    Keul, Christine
    Seidl, Judith
    Gueth, Jan-Frederik
    Liebermann, Anja
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (12) : 4519 - 4530
  • [39] Effect of Surface Treatments with Plasma and Chemical Bond on Shear Bond Strength of Acrylic Denture Teeth to Flexible and Heat-Cured Denture Base Material: An In Vitro Study
    Abood, Ghazwan A.
    Mohammed, Ali A.
    Abdullah, Zainab S.
    Fatalla, Abdalbseet A.
    DENTAL HYPOTHESES, 2024, 15 (01): : 8 - 10
  • [40] Release of dibenzoyl peroxide from polymethyl methacrylate denture base resins: An in vitro evaluation
    Boeckler, Arne F.
    Morton, Dean
    Poser, Sven
    Dette, Karl-Ernst
    DENTAL MATERIALS, 2008, 24 (12) : 1602 - 1607