Biocompatibility of polymethyl methacrylate heat-polymerizing denture base resin copolymerized with antimicrobial monomers

被引:1
|
作者
Rao, Sowmya [1 ]
Surya, Suprith [2 ]
Pavan, S. R. [4 ]
Ali, Saheb [3 ]
Prabhu, Ashwini [4 ]
Ginjupalli, Kishore [5 ]
Shenoy, Pooja Umesh [4 ]
Das, Ranajit [4 ]
Nandish, B. T. [1 ]
机构
[1] Yenepoya Deemed Univ, Yenepoya Dent Coll, Dept Dent Mat, Mangalore 575018, Karnataka, India
[2] Yenepoya Deemed Univ, Adv Surg Skill Enhancement Div ASSEND, Mangalore 575018, Karnataka, India
[3] Saveetha Univ, Saveetha Inst Med & Tech Sci SIMATS, Saveetha Dent Coll & Hosp, Dept Periodont, Chennai 600077, Tamil Nadu, India
[4] Yenepoya Deemed Univ, Yenepoya Res Ctr, Mangalore 575018, Karnataka, India
[5] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Dent Mat, Manipal 576104, Karnataka, India
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 03期
关键词
NANOPARTICLES; ZEBRAFISH;
D O I
10.1016/j.prosdent.2024.06.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Quaternary ammonium (QA)-based monomers such as dimethyl-hexadecyl-methacryloxyethyl-ammonium iodide (DHMAI) and 2-dimethyl-2-dodecyl-1-methacryloxyethyl ammonium iodine (DDMAI) have been investigated as copolymerizable monomers to impart antimicrobial activity to dental restorative and prosthetic materials. However, the biocompatibility of these antimicrobial monomers needs to be investigated in vivo before their clinical use. Purpose. The purpose of this study was to assess the in vivo biocompatibility of polymethyl methacrylate (PMMA) heat-polymerizing denture base resin copolymerized with varying concentrations of DHMAI and DDMAI. Material and methods. The toxicity and genotoxicity of the antimicrobial monomers (DHMAI 5 mu g/mL and DDMAI 20 mu g/mL) at 1 to 100 mu g/mL concentrations were investigated against zebrafish embryos (Danio rerio, n=10) using a zebrafish embryotoxicity test (ZET) or fish embryotoxicity test (FET) and comet assay, respectively. Further, DHMAI 5 mu g/mL and DDMAI 20 mu g/mL were incorporated into a conventional PMMA denture base system and a similar test was done on specimens of modified PMMA resin. For the evaluation of in vivo biocompatibility, modified PMMA specimens were subcutaneously implanted into Wistar rats (n=6) and biochemical, hematological, and histopathological parameters were investigated. Results were analyzed and compared using ANOVA and the Tukey post hoc test (alpha=.05). Results. Toxicity and genotoxicity studies using zebrafish embryos revealed that the incorporation of monomer to PMMA did not increase the toxicity, as confirmed by post-hour fertilization. Modified PMMA did not affect the hematological parameters, such as red blood cell (RBC) and white blood cell (WBC) except for the platelet count, which was significantly increased (P<.001), and the biochemical parameter, such as total protein (TP), blood urea nitrogen (BUN), serum glutamic-oxaloacetic transaminase (SGOT), triglyceride (TG), creatinine (Crea), total cholesterol, and serum glutamic pyruvic transaminase (SGPT), except for high-density lipoprotein (HDL) cholesterol, which was significantly decreased (P<.01). Histopathologically, no changes were observed in the sections of the liver, kidney, spleen, and subcutaneous tissues in the modified PMMA implanted rats. Additionally, no significant variation was found in the expression of immunohistochemical marker tumor necrosis factor alpha (TNF-alpha), confirming the noninflammatory response exerted by the modified PMMA on experimental rats. Conclusions. Zebrafish embryos treated with modified PMMA specimens demonstrated favorable biological properties and did not exhibit significant cytotoxicity and genotoxicity. Subcutaneously implanted modified PMMA did not cause any major hematological, biochemical, and histopathological alterations in Wistar albino rats, thus confirming the biocompatibility of PMMA heat-polymerizing denture base resin incorporated with DHMAI and DDMAI for dental applications.
引用
收藏
页码:644e1 / 644e10
页数:10
相关论文
共 50 条
  • [1] Flexural strength, biocompatibility, and antimicrobial activity of a polymethyl methacrylate denture resin enhanced with graphene and silver nanoparticles
    Bacali, Cecilia
    Baldea, Ioana
    Moldovan, Marioara
    Carpa, Rahela
    Olteanu, Diana Elena
    Filip, Gabriela Adriana
    Nastase, Vivi
    Lascu, Liana
    Badea, Mandra
    Constantiniuc, Mariana
    Badea, Florin
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (08) : 2713 - 2725
  • [2] Flexural strength, biocompatibility, and antimicrobial activity of a polymethyl methacrylate denture resin enhanced with graphene and silver nanoparticles
    Cecilia Bacali
    Ioana Baldea
    Marioara Moldovan
    Rahela Carpa
    Diana Elena Olteanu
    Gabriela Adriana Filip
    Vivi Nastase
    Liana Lascu
    Mandra Badea
    Mariana Constantiniuc
    Florin Badea
    Clinical Oral Investigations, 2020, 24 : 2713 - 2725
  • [3] Effect of heat treatment of polymethyl methacrylate powder on mechanical properties of denture base resin
    Kawaguchi, Tomohiro
    Lassila, Lippo V. J.
    Sasaki, Hirono
    Takahashi, Yutaka
    Vallittu, Pekka K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 39 : 73 - 78
  • [4] Flexural strength of polymethyl methacrylate copolymers as a denture base resin
    Hayran, Yeliz
    Keskin, Yasemin
    DENTAL MATERIALS JOURNAL, 2019, 38 (04) : 678 - 686
  • [5] Reinforcement of polymethyl methacrylate denture base resin with ZnO nanostructures
    Salahuddin, Nehal
    El-Kemary, Maged
    Ibrahim, Ebtisam
    INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2018, 15 (02) : 448 - 459
  • [6] BONDING OF RESIN TEETH TO THE POLYMETHYL METHACRYLATE DENTURE BASE MATERIAL
    VALLITTU, PK
    ACTA ODONTOLOGICA SCANDINAVICA, 1995, 53 (02) : 99 - 104
  • [7] Tensile bond strength of auto-polymerizing and heat-polymerizing denture reliners on the conventional and CAD-CAM denture base materials
    Alfaraj, Amal
    Chu, Tien-Min G.
    Alouthah, Hesham
    Yang, Chao-Chieh
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 87 - 95
  • [8] INFLUENCE OF CONCENTRATIONS OF METHACRYLATE AND ACRYLATE MONOMERS ON THE PROPERTIES OF FIBER REINFORCED POLYMETHYL METHACRYLATE DENTURE BASE MATERIALS
    Tugut, Faik
    Turgut, Mehmet
    Saraydin, Dursun
    ACTA CHEMICA IASI, 2018, 26 (02) : 329 - 350
  • [9] 3D-Printed vs. Heat-Polymerizing and Autopolymerizing Denture Base Acrylic Resins
    Perea-Lowery, Leila
    Gibreel, Mona
    Vallittu, Pekka K.
    Lassila, Lippo, V
    MATERIALS, 2021, 14 (19)
  • [10] Effect of Copolymerizing Antimicrobial Monomers on Mechanical Properties of PMMA Heat Cure Denture Base Resin
    Rao, Sowmya
    Nandish, B.T.
    Ginjupalli, Kishore
    Jayaprakash, K.
    Trends in Biomaterials and Artificial Organs, 2022, 36 (Special Issue 1): : 56 - 58