The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials

被引:2
|
作者
Polychronakis, Nick [1 ]
Dimitriadi, Maria [2 ]
Polyzois, Gregory [1 ]
Eliades, George [2 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[2] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Biomat, Athens, Greece
关键词
Heat-cured denture base acrylics; Cooling procedures; Methyl methacrylate monomer elution; Ultra-fast liquid chromatography; RESIDUAL MONOMER; ACRYLIC RESIN; METHYL-METHACRYLATE; CYTOTOXICITY; RELEASE; WATER; LEVEL; TIME;
D O I
10.1590/1678-7757-2022-0161
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. Methodology: Disk-shaped specimens (empty set:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37 degrees C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student's and Welch's t-test (alpha=0.05). Results: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). Conclusions: The cooling procedures may affect the monomer elution from denture base materials. The E procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A Comparison of the Wetting Ability of Three Artificial Saliva Substitutes on Heat-Cured Denture Base Resin - An In vitro Study
    Ranjan, Madhu
    Keshari, Mritunjay Kumar
    Sinha, Tushar
    Bhatia, Mehtaab Singh
    Rani, Priya
    Prakash, Jayant
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1016 - S1019
  • [42] Experimental studies on bacterio-stasis of heat-cured polyacrylic resin denture base when added chitosan
    Zhu, Lin
    Xu, Pei-Cheng
    Zhang, Jian-Zhong
    Li, De-Yi
    Fudan University Journal of Medical Sciences, 2004, 31 (04): : 411 - 413
  • [43] Addition of Nanohybrids Particles and Fiber to Heat Cured PMMA Denture Base Materials
    Ismail, Intisar J.
    Diya, Balkees M.
    Ebrahim, Farah J.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (10): : 20 - 29
  • [44] Effect of fiber reinforcement on impact strength of heat polymerized polymethyl methacrylate denture base resin: in vitro study and SEM analysis
    Mowade, Tushar Krishnarao
    Dange, Shankar Pandurang
    Thakre, Mrunali Balkrushna
    Kamble, Vaibhav Deorao
    JOURNAL OF ADVANCED PROSTHODONTICS, 2012, 4 (01): : 30 - 36
  • [45] Effect of High Molecular Nano-Chitosan Addition on The Impact Strength of Heat Polymerized Polymethyl Methacrylate Denture Base Resin
    Adiana, Ika Devi
    Abidin, Trimurni
    Syafiar, Lasminda
    PROCEEDINGS OF THE INTERNATIONAL DENTAL CONFERENCE OF SUMATERA UTARA 2017 (IDCSU 2017), 2017, 8 : 130 - 133
  • [46] EFFECT OF POLYMERIZATION PROCEDURE ON CYTOTOXICITY OF CURED RESIN DENTURE BASE MATERIALS
    WICTORIN, L
    HENSTENPETTERSEN, A
    JOURNAL OF DENTAL RESEARCH, 1977, 56 : A186 - A186
  • [47] Residual methyl methacrylate monomer, water sorption, and water solubility of hypoallergenic denture base materials
    Pfeiffer, P
    Rosenbauer, EU
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (01): : 72 - 78
  • [48] The effect of different cooling procedures on mechanical properties of denture base materials measured by instrumented indentation testing
    Polychronakis, Nick
    Dimitriadi, Maria
    Ioannidis, Alexis
    Papadopoulos, Triantafyllos
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (03) : 326 - 331
  • [49] Effect of methyl methacrylate monomer on bond strength of denture base resin to acrylic teeth
    Marra, Julie
    Paleari, Andre Gustavo
    Pero, Ana Carolina
    de Souza, Raphael Freitas
    Barbosa, Debora Barros
    Compagnoni, Marco Antonio
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2009, 29 (04) : 391 - 395
  • [50] Thermal and dynamic mechanical properties of microwave and heat-cured poly(methyl methacrylate) used as dental base material
    Muhtarogullari, IY
    Dogan, A
    Muhtarogullari, M
    Usanmaz, A
    JOURNAL OF APPLIED POLYMER SCIENCE, 1999, 74 (12) : 2971 - 2978