The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials

被引:2
|
作者
Polychronakis, Nick [1 ]
Dimitriadi, Maria [2 ]
Polyzois, Gregory [1 ]
Eliades, George [2 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[2] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Biomat, Athens, Greece
关键词
Heat-cured denture base acrylics; Cooling procedures; Methyl methacrylate monomer elution; Ultra-fast liquid chromatography; RESIDUAL MONOMER; ACRYLIC RESIN; METHYL-METHACRYLATE; CYTOTOXICITY; RELEASE; WATER; LEVEL; TIME;
D O I
10.1590/1678-7757-2022-0161
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. Methodology: Disk-shaped specimens (empty set:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37 degrees C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student's and Welch's t-test (alpha=0.05). Results: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). Conclusions: The cooling procedures may affect the monomer elution from denture base materials. The E procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique
    May, Lee Wei
    John, Jacob
    Seong, Lim Ghee
    Abidin, Zubaidah Zanul
    Ibrahim, Norliza
    Danaee, Mahmoud
    Mohd, Noorhayati Raja
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2021, 21 (02): : 198 - 203
  • [22] Effect of ethanol treatment on mechanical properties of heat-polymerized polymethyl methacrylate denture base polymer
    Basavarajappa, Santhosh
    Abdullah Alkheraif, Abdul Aziz
    Alhijji, Saleh M.
    Matinlinna, Jukka Pekka
    Vallittu, Pekka Kalevi
    DENTAL MATERIALS JOURNAL, 2017, 36 (06) : 834 - 841
  • [23] INFLUENCE OF CONCENTRATIONS OF METHACRYLATE AND ACRYLATE MONOMERS ON THE PROPERTIES OF FIBER REINFORCED POLYMETHYL METHACRYLATE DENTURE BASE MATERIALS
    Tugut, Faik
    Turgut, Mehmet
    Saraydin, Dursun
    ACTA CHEMICA IASI, 2018, 26 (02) : 329 - 350
  • [24] Peel Bond Strength of Two Silicone Soft Liners to a Heat-cured Denture Base Resin
    Demir, Hakan
    Dogan, Arife
    Dogan, Orhan Murat
    Keskin, Selda
    Bolayir, Giray
    Soygun, Koray
    JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (06): : 579 - 584
  • [25] A Color Stability Comparison of Conventional and CAD/CAM Polymethyl Methacrylate Denture Base Materials
    Dayan, Cagatay
    Guven, Melahat Celik
    Gencel, Burc
    Bural, Canan
    ACTA STOMATOLOGICA CROATICA, 2019, 53 (02) : 158 - 167
  • [26] Adhesion of Denture Characterizing Composites to Heat-Cured, CAD/CAM and 3D Printed Denture Base Resins
    Choi, Joanne Jung Eun
    Ramani, Rishi Sanjay
    Ganjigatti, Ritu
    Uy, Caira Ellyse
    Plaksina, Polina
    Waddell, John Neil
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (01): : 83 - 90
  • [27] A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA)
    Al-Dwairi, Ziad N.
    Tahboub, Kawkab Y.
    Baba, Nadim Z.
    Goodacre, Charles J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04): : 341 - 349
  • [28] The Effect of Surface Treatments on Tensile Bond Strength between a Silicone Soft Liner and a Heat-Cured Denture Base Resin
    Soygun, Koray
    Bolayir, Giray
    Dogan, Arife
    Demir, Hakan
    Dogan, Orhan Murat
    Keskin, Selda
    JOURNAL OF ADHESION, 2011, 87 (09): : 951 - 965
  • [29] Effect of a Surface Sealant Agent on the Color Stability and Surface Roughness of Polymethyl Methacrylate and Nylon Denture Base Materials
    Giti, Rashin
    Kazemi, Razieh
    Mohammadi, Farhad
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (01) : 70 - 78
  • [30] The modification of acrylic denture base resin as materials for artificial teeth: Effect of hydroquinone and methyl methacrylate monomer
    Banjong, Pornchiwin
    Sankham, Natthawika
    Duangnga, Watchara
    Intatha, Uraiwan
    Soykeabkaew, Nattakan
    Duangphet, Sitthi
    SCIENCEASIA, 2020, 46 : 97 - 101