The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials

被引:2
|
作者
Polychronakis, Nick [1 ]
Dimitriadi, Maria [2 ]
Polyzois, Gregory [1 ]
Eliades, George [2 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[2] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Biomat, Athens, Greece
关键词
Heat-cured denture base acrylics; Cooling procedures; Methyl methacrylate monomer elution; Ultra-fast liquid chromatography; RESIDUAL MONOMER; ACRYLIC RESIN; METHYL-METHACRYLATE; CYTOTOXICITY; RELEASE; WATER; LEVEL; TIME;
D O I
10.1590/1678-7757-2022-0161
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. Methodology: Disk-shaped specimens (empty set:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37 degrees C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student's and Welch's t-test (alpha=0.05). Results: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). Conclusions: The cooling procedures may affect the monomer elution from denture base materials. The E procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water.
引用
收藏
页数:7
相关论文
共 50 条
  • [2] Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins
    Asar, Neset Volkan
    Albayrak, Hamdi
    Korkmaz, Turan
    Turkyilmaz, Ilser
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (03): : 241 - 247
  • [3] Effect of bench cooling on the dimensional accuracy of heat-cured acrylic denture base material
    Kimoto, S
    Kobayashi, N
    Kobayashi, K
    Kawara, M
    JOURNAL OF DENTISTRY, 2005, 33 (01) : 57 - 63
  • [4] THE OCCURRENCE OF POROSITY IN A HEAT-CURED POLY (METHYL-METHACRYLATE) DENTURE BASE RESIN
    WOLFAARDT, JF
    CLEATONJONES, P
    FATTI, P
    JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (03): : 393 - 400
  • [5] Enhancement of the Tensile and the Compression Properties for Heat-Cured Acrylic Resin Denture Base Materials
    Hammed, Mohammed Gh.
    Al-Fahdawi, Ibrahim H.
    Motlak, Moaaed
    BAGHDAD SCIENCE JOURNAL, 2018, 15 (04) : 449 - 454
  • [6] BONDING OF PLASTIC TEETH TO HEAT-CURED DENTURE BASE RESINS
    SCHOONOVER, IC
    FISCHER, TE
    SERIO, AF
    SWEENEY, WT
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1952, 44 (03): : 285 - 287
  • [7] Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins (vol 5, pg 241, 2013)
    Asar, Neset Volkan
    Albayrak, Hamdi
    Korkmaz, Turan
    Turkyilmaz, Ilser
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (04): : 502 - 502
  • [8] Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials
    Lamfon, Hanadi A.
    Hamouda, Ibrahim M.
    JOURNAL OF BIOMEDICAL RESEARCH, 2019, 33 (02): : 139 - 144
  • [9] Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials
    Hanadi A.Lamfon
    Ibrahim M.Hamouda
    The Journal of Biomedical Research, 2019, 33 (02) : 139 - 144
  • [10] The effect of Esthetic fibers on impact resistance of a conventional heat-cured denture base resin
    Dogan, Orhan Murat
    Bolayir, Giray
    Keskin, Selda
    Dogan, Arife
    Bek, Bulent
    Boztug, Ali
    DENTAL MATERIALS JOURNAL, 2007, 26 (02) : 232 - 239