Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials

被引:0
|
作者
Hanadi A.Lamfon
Ibrahim M.Hamouda
机构
[1] Maxillofacial and Oral Rehabilitation Department, Umm Al-Qura University
[2] Conservative Dentistry, Faculty of Dentistry, Umm Al-Qura University
[3] Dental Biomaterials, Faculty of Dentistry, Mansoura University
关键词
denture distortion; flange discrepancy; acrylic resin; occlusal discrepancies; denture base;
D O I
暂无
中图分类号
R783.1 [牙科材料学];
学科分类号
080502 ;
摘要
This study was conducted to investigate the maxillary denture bases and occlusal discrepancies using the Vertex Thermosens in comparison with the conventional polymethyl-methacrylate materials. Twenty maxillary denture bases were prepared from the Vertex ThermoSens and a conventional heat-cured denture base materials. Acrylic maxillary second molars were arranged in their respective positions on the ridge. After curing of both types of denture bases, they were deflasked with their respective master casts. Reference points were prepared for measurements of the antero-posterior and cross-arch dimensions at the denture borders using caliper device. Furthermore, the teeth discrepancies were measured between reference points in the ligual aspect of the second maxillary molars. The recorded data was analyzed using SPSS statistical software version 20. The results showed initial shrinkage of both denture bases in the antero-posterior and cross-arch dimensions immediately after decasting. This contraction was compensated gradually during storage in water up to 2 weeks. Regarding the variable time, there was a significant difference between the tested materials. Moreover, the results revealed occlusal discrepancies and shifting of teeth inward immediately after decasting, followed by outward movement after storage in water for 2 weeks. Regarding the variables time and materials, there were significant differences. Both materials exhibited inward shrinkage in the antero-posterior and cross-arch dimensions immediately after decasting. Both denture bases showed inward shifting of teeth immediately after decasting, followed by outward movement after storage in water up to 2 weeks.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 49 条
  • [1] Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials
    Lamfon, Hanadi A.
    Hamouda, Ibrahim M.
    JOURNAL OF BIOMEDICAL RESEARCH, 2019, 33 (02): : 139 - 144
  • [2] BONDING OF PLASTIC TEETH TO HEAT-CURED DENTURE BASE RESINS
    SCHOONOVER, IC
    FISCHER, TE
    SERIO, AF
    SWEENEY, WT
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1952, 44 (03): : 285 - 287
  • [3] The effect of Esthetic fibers on impact resistance of a conventional heat-cured denture base resin
    Dogan, Orhan Murat
    Bolayir, Giray
    Keskin, Selda
    Dogan, Arife
    Bek, Bulent
    Boztug, Ali
    DENTAL MATERIALS JOURNAL, 2007, 26 (02) : 232 - 239
  • [4] Enhancement of the Tensile and the Compression Properties for Heat-Cured Acrylic Resin Denture Base Materials
    Hammed, Mohammed Gh.
    Al-Fahdawi, Ibrahim H.
    Motlak, Moaaed
    BAGHDAD SCIENCE JOURNAL, 2018, 15 (04) : 449 - 454
  • [5] ADHERENCE OF CANDIDA-ALBICANS TO HEAT-CURED DENTURE BASE ACRYLIC
    MIHALOW, DM
    SHAY, KJ
    SOHNLE, PG
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 165 - 165
  • [6] The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
    Polychronakis, Nick
    Dimitriadi, Maria
    Polyzois, Gregory
    Eliades, George
    JOURNAL OF APPLIED ORAL SCIENCE, 2022, 30
  • [7] Adhesion of Denture Characterizing Composites to Heat-Cured, CAD/CAM and 3D Printed Denture Base Resins
    Choi, Joanne Jung Eun
    Ramani, Rishi Sanjay
    Ganjigatti, Ritu
    Uy, Caira Ellyse
    Plaksina, Polina
    Waddell, John Neil
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (01): : 83 - 90
  • [8] Effect of bench cooling on the dimensional accuracy of heat-cured acrylic denture base material
    Kimoto, S
    Kobayashi, N
    Kobayashi, K
    Kawara, M
    JOURNAL OF DENTISTRY, 2005, 33 (01) : 57 - 63
  • [9] THE OCCURRENCE OF POROSITY IN A HEAT-CURED POLY (METHYL-METHACRYLATE) DENTURE BASE RESIN
    WOLFAARDT, JF
    CLEATONJONES, P
    FATTI, P
    JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (03): : 393 - 400
  • [10] Sheer bond strength of resin teeth to heat-cured and light-cured denture base resin
    Cunningham, JL
    JOURNAL OF ORAL REHABILITATION, 2000, 27 (04) : 312 - 316