Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings

被引:60
|
作者
Wu, PC
Li, YY
Chiang, CM
Huang, CY
Lee, CC
Li, FC
Su, HJ
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Environm & Occupat Hlth, Tainan 70428, Taiwan
[2] Natl Cheng Kung Univ, Coll Design & Planning, Dept Architecture, Tainan 70101, Taiwan
关键词
microbes; fungi; bacteria; office building; ventilation; air change rate;
D O I
10.1111/j.1600-0668.2004.00313.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R-2 = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R-2 = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [41] Short-term mechanical ventilation of air-conditioned residential buildings: A general design framework and guidelines
    Ai, Z. T.
    Mak, C. M.
    BUILDING AND ENVIRONMENT, 2016, 108 : 12 - 22
  • [42] Energy use, indoor temperature and possible adaptation strategies for air-conditioned office buildings in face of global warming
    Guan, Lisa
    BUILDING AND ENVIRONMENT, 2012, 55 : 8 - 19
  • [43] Initial study on the impact of thermal history on building occupants' thermal assessments in actual air-conditioned office buildings
    Fadeyi, Moshood Olawale
    BUILDING AND ENVIRONMENT, 2014, 80 : 36 - 47
  • [44] Energy performance and optimal control of air-conditioned buildings with envelopes enhanced by phase change materials
    Zhu, Na
    Wang, Shengwei
    Ma, Zhenjun
    Sun, Yongjun
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (10) : 3197 - 3205
  • [45] Field study on thermal comfort and energy saving potential in 11 split air-conditioned office buildings in Changsha, China
    Wu, Zhibin
    Li, Nianping
    Wargocki, Pawel
    Peng, Jingqing
    Li, Jingming
    Cui, Haijiao
    ENERGY, 2019, 182 : 471 - 482
  • [46] Physicochemical risk factors for building-related symptoms in air-conditioned office buildings: Ambient particles and combined exposure to indoor air pollutants
    Azuma, Kenichi
    Ikeda, Koichi
    Kagi, Naoki
    Yanagi, U.
    Osawa, Haruki
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 616 : 1649 - 1655
  • [47] The return of natural ventilation - As architects rediscover the benefits of fresh air as an alternative to hermetically sealed, air-conditioned buildings, they discover new architectural forms
    Willmert, T
    ARCHITECTURAL RECORD, 2001, 189 (07) : 137 - +
  • [48] CHARACTERISTICS OF ELECTRICITY CONSUMPTION IN COMMERCIAL BUILDINGS - SURVEY OF ELECTRICITY CONSUMPTION IN FULLY AIR-CONDITIONED OFFICE BUILDINGS AND HOTELS IN HONG-KONG, IMPLICATIONS FOR ENERGY-CONSERVATION IN BUILDINGS
    LAM, JC
    CHAN, ALS
    BUILDING RESEARCH AND INFORMATION, 1994, 22 (06): : 313 - 318
  • [49] Thermal adaptation of different set point temperature modes and energy saving potential in split air-conditioned office buildings during summer
    Yan, Haiyan
    Shi, Fangning
    Sun, Zhen
    Yuan, Guodong
    Wang, Minli
    Dong, Mengru
    BUILDING AND ENVIRONMENT, 2022, 225
  • [50] An evaluation of the appropriateness of using overall thermal transfer value (OTTV) to regulate envelope energy performance of air-conditioned buildings
    Yik, FWH
    Wan, KSY
    ENERGY, 2005, 30 (01) : 41 - 71