Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings

被引:60
|
作者
Wu, PC
Li, YY
Chiang, CM
Huang, CY
Lee, CC
Li, FC
Su, HJ
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Environm & Occupat Hlth, Tainan 70428, Taiwan
[2] Natl Cheng Kung Univ, Coll Design & Planning, Dept Architecture, Tainan 70101, Taiwan
关键词
microbes; fungi; bacteria; office building; ventilation; air change rate;
D O I
10.1111/j.1600-0668.2004.00313.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R-2 = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R-2 = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings.
引用
下载
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [1] Performance of noise indices in air-conditioned landscaped office buildings
    Tang, SK
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (03): : 1657 - 1663
  • [2] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [3] Characteristics of radon and its progeny concentrations in air-conditioned office buildings in Tokyo
    Tokonami, S
    Furukawa, M
    Shicchi, Y
    Sanada, T
    Yamada, Y
    RADIATION PROTECTION DOSIMETRY, 2003, 106 (01) : 71 - 76
  • [4] Building energy performance of air-conditioned office buildings in Hong Kong
    Chan, RYC
    Lam, JC
    Li, DHW
    Tsang, EKW
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 985 - 992
  • [5] The Influence of Glass Types on the Performance of Air-Conditioned Office Buildings in Australia
    Guan, Lisa
    SUSTAINABLE CONSTRUCTION MATERIALS AND COMPUTER ENGINEERING, 2012, 346 : 34 - 39
  • [6] Daylighting and energy analysis for air-conditioned office buildings
    Lam, JC
    Li, DHW
    ENERGY, 1998, 23 (02) : 79 - 89
  • [7] Ventilation characteristics of an air-conditioned office building in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (03) : 241 - 255
  • [8] Relationship of multiple indoor air pollutants and sick building syndrome at air-conditioned office buildings in Taiwan
    Wu, PC
    Li, YY
    Chiang, CM
    Su, HJ
    Lee, CC
    EPIDEMIOLOGY, 2004, 15 (04) : S16 - S16
  • [9] Impact of Window's Height on Energy Efficiency in Air-Conditioned Office Buildings
    Al-Ashwal, Najib Taher
    Hassan, Ahmad Sanusi
    ADVANCED SCIENCE LETTERS, 2017, 23 (11) : 11540 - 11544
  • [10] Implication of global warming on air-conditioned office buildings in Australia
    Guan, Lisa
    BUILDING RESEARCH AND INFORMATION, 2009, 37 (01): : 43 - 54