Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings

被引:60
|
作者
Wu, PC
Li, YY
Chiang, CM
Huang, CY
Lee, CC
Li, FC
Su, HJ
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Environm & Occupat Hlth, Tainan 70428, Taiwan
[2] Natl Cheng Kung Univ, Coll Design & Planning, Dept Architecture, Tainan 70101, Taiwan
关键词
microbes; fungi; bacteria; office building; ventilation; air change rate;
D O I
10.1111/j.1600-0668.2004.00313.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R-2 = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R-2 = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings.
引用
下载
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [21] The influence of internal load density on the energy and thermal performance of air-conditioned office buildings in the face of global warming
    Guan, Lisa
    ARCHITECTURAL SCIENCE REVIEW, 2015, 58 (02) : 162 - 173
  • [22] CONSISTENT PATTERN OF ELEVATED SYMPTOMS IN AIR-CONDITIONED OFFICE BUILDINGS - A REANALYSIS OF EPIDEMIOLOGIC STUDIES
    MENDELL, MJ
    SMITH, AH
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (10) : 1193 - 1199
  • [23] An analysis of electricity end-use in air-conditioned office buildings in Hong Kong
    Lam, JC
    Li, DHW
    Cheung, SO
    BUILDING AND ENVIRONMENT, 2003, 38 (03) : 493 - 498
  • [24] Multiple regression models for energy use in air-conditioned office buildings in different climates
    Lam, Joseph C.
    Wan, Kevin K. W.
    Liu, Dalong
    Tsang, C. L.
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) : 2692 - 2697
  • [25] A study on the identification and quantification of sources of VOCs in 5 air-conditioned Singapore office buildings
    Zuraimi, MS
    Tham, KW
    Sekhar, SC
    BUILDING AND ENVIRONMENT, 2004, 39 (02) : 165 - 177
  • [26] The effects of ventilation operations in determining contributions of VOCs sources in air-conditioned tropical buildings
    Zuraimi, MS
    Tham, KW
    Sekhar, SC
    BUILDING AND ENVIRONMENT, 2003, 38 (01) : 23 - 32
  • [27] Investigation on typical occupant behavior in air-conditioned office buildings for South China’s Pearl River Delta
    Manning He
    Huiwang Pen
    Meixiang Li
    Yu Huang
    Da Yan
    Siwei Lou
    Liwei Wen
    Architectural Intelligence , 1 (1):
  • [28] Associations of occupant demographics, thermal history and obesity variables with their thermal comfort in air-conditioned and mixed-mode ventilation office buildings
    Rupp, Ricardo Forgiarini
    Kim, Jungsoo
    de Dear, Richard
    Ghisi, Enedir
    BUILDING AND ENVIRONMENT, 2018, 135 : 1 - 9
  • [29] Particle concentrations and sizes with normal and high efficiency air filtration in a sealed air-conditioned office building
    Fisk, WJ
    Faulkner, D
    Sullivan, D
    Mendell, MJ
    AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (06) : 527 - 544
  • [30] Simple regression models for fully air-conditioned public sector office buildings in subtropical climates
    Lam, Joseph C.
    Chan, Ricky Y.C.
    Li, Danny H.W.
    2002, University of Sydney (45)