microbes;
fungi;
bacteria;
office building;
ventilation;
air change rate;
D O I:
10.1111/j.1600-0668.2004.00313.x
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R-2 = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R-2 = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings.
机构:
City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
Lam, JC
Li, DHW
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
Li, DHW
Cheung, SO
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
机构:
City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
Lam, Joseph C.
Wan, Kevin K. W.
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
Wan, Kevin K. W.
Liu, Dalong
论文数: 0引用数: 0
h-index: 0
机构:
Xian Univ Architecture & Technol, Sch Architecture, Xian 710055, Shaanxi, Peoples R ChinaCity Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
Liu, Dalong
Tsang, C. L.
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
机构:
Building Energy Research Group, Dept. of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong KongBuilding Energy Research Group, Dept. of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
Lam, Joseph C.
Chan, Ricky Y.C.
论文数: 0引用数: 0
h-index: 0
机构:
Building Energy Research Group, Dept. of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong KongBuilding Energy Research Group, Dept. of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
Chan, Ricky Y.C.
Li, Danny H.W.
论文数: 0引用数: 0
h-index: 0
机构:
Building Energy Research Group, Dept. of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong KongBuilding Energy Research Group, Dept. of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong