Technical Note: On GAFChromic EBT-XD film and the lateral response artifact

被引:55
|
作者
Lewis, David F. [1 ]
Chan, Maria F. [2 ]
机构
[1] RC Film Consulting LLC, 54 Benedict Rd, Monroe, CT 06468 USA
[2] Mem Sloan Kettering Canc Ctr, 136 Mt View Blvd, Basking Ridge, NJ 07920 USA
关键词
radiochromic film dosimetry; QA; IMRT; radiotherapy; lateral response; FLAT-BED SCANNERS; RADIOCHROMIC FILM; NONUNIFORMITY CORRECTION; DOSIMETRY; CALIBRATION;
D O I
10.1118/1.4939226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The new radiochromic film, GAFChromic EBT-XD, contains the same active material, lithium-10,12-pentacosadiynoate, as GAFChromic EBT3, but the crystalline form is different. This work investigates the effect of this change on the well-known lateral response artifact when EBT-XD film is digitized on a flatbed scanner. Methods: The dose response of a single production lot of EBT-XD was characterized by scanning an unexposed film plus a set of films exposed to doses between 2.5 and 50 Gy using 6 MV photons. To characterize the lateral response artifact, the authors used the unexposed film plus a subset of samples exposed to doses between 20 and 50 Gy. Digital images of these films were acquired at seven discrete lateral locations perpendicular to the scan direction on three Epson 10000XL scanners. Using measurements at the discrete lateral positions, the scanner responses were determined as a function of the lateral position of the film From the data for each scanner, a set of coefficients were derived whereby measured response values could be corrected to remove the effects of the lateral response artifact. The EBT-XD data were analyzed as in their previous work and compared to results reported for EBT3 in that paper. Results: For films scanned in the same orientation and having equal responses, the authors found that the lateral response artifact for EBT-XD and EBT3 films was remarkably similar. For both films, the artifact increases with increased net response. However, as EBT-XD is less sensitive than EBT3, a greater exposure dose is required to reach the same net response. On this basis, the lower sensitivity of EBT-XD relative to EBT3 results in less net response change for equal exposure and a reduction in the impact of the lateral response artifact. Conclusions: The shape of the crystalline active component in EBT-XD and EBT3 does not affect the fundamental existence of the lateral response artifact when the films are digitized on flatbed scanners. Owing its lower sensitivity, EBT-XD film requires higher dose to reach the same response as EBT3, resulting in lesser impact of the lateral response artifact. For doses >10 Gy, the slopes of the EBT-XD red and green channel dose response curves are greater than the corresponding ones for EBT3. For these two reasons, the authors prefer EBT-XD for doses exceeding about 10 Gy. 2016 American Association of Physicists in Medicine.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 50 条
  • [1] Technical Note: Initial characterization of the new EBT-XD Gafchromic film
    Grams, Michael P.
    Gustafson, Jon M.
    Long, Kenneth M.
    de los Santos, Luis E. Fong
    MEDICAL PHYSICS, 2015, 42 (10) : 5782 - 5786
  • [2] Dosimetric response of Gafchromic™ EBT-XD film to therapeutic protons
    Guan, Fada
    Wang, Xiaochun
    Yang, Ming
    Draeger, Emily
    Han, Dae
    Iga, Kiminori
    Guo, Fanqing
    Perles, Luis
    Li, Yuting
    Sahoo, Narayan
    Mohan, Radhe
    Chen, Zhe
    PRECISION RADIATION ONCOLOGY, 2023, 7 (01): : 15 - 26
  • [3] Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification
    Palmer, Antony L.
    Dimitriadis, Alexis
    Nisbet, Andrew
    Clark, Catharine H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22): : 8741 - 8752
  • [4] Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry
    Smyth, Lloyd
    Alves, Andrew
    Collins, Katherine
    Beveridge, Sabeena
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 1095 - 1106
  • [5] Temperature dependent dose readout of Gafchromic EBT3 and EBT-XD film and clinical relevance in SRT
    Buchauer, K.
    Plasswilm, L.
    Schiefer, J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S807 - S808
  • [6] Clinical Comparison of Gafchromic EBT-XD Film to Gafchromic EBT3 Film When Utilized as An Absolute Dose Verification Method in Stereotactic Radiotherapy
    Goodman, R.
    Murphy, T.
    Siergiej, D.
    Schroeder, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E280 - E280
  • [7] Influence of three calibration methods of EBT-XD GAFChromic Film for the dosimetric verification of SRS plans
    Hussain, Amjad
    Hudson, Alana
    Muhammad, Wazir
    Ploquine, Nicolas
    MEDICAL PHYSICS, 2017, 44 (08) : 4384 - 4384
  • [8] Characterization of scanning orientation and lateral response artifact for EBT4 Gafchromic film
    Miura, Hideharu
    Ozawa, Shuichi
    Okazue, Toshiya
    Enosaki, Tsubasa
    Nagata, Yasushi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (08):
  • [9] Technical note: Proton beam dosimetry at ultra-high dose rates (FLASH): Evaluation of GAFchromic™ (EBT3, EBT-XD) and OrthoChromic (OC-1) film performances
    Institut de Cancérologie de l'Ouest, Saint-Herblain, France
    不详
    不详
    Med. Phys., 4 (2732-2745):
  • [10] Technical Note: Homogeneity of Gafchromic® EBT2 film
    Hartmann, Bernadette
    Martisikova, Maria
    Jaekel, Oliver
    MEDICAL PHYSICS, 2010, 37 (04) : 1753 - 1756