Technical Note: On GAFChromic EBT-XD film and the lateral response artifact

被引:55
|
作者
Lewis, David F. [1 ]
Chan, Maria F. [2 ]
机构
[1] RC Film Consulting LLC, 54 Benedict Rd, Monroe, CT 06468 USA
[2] Mem Sloan Kettering Canc Ctr, 136 Mt View Blvd, Basking Ridge, NJ 07920 USA
关键词
radiochromic film dosimetry; QA; IMRT; radiotherapy; lateral response; FLAT-BED SCANNERS; RADIOCHROMIC FILM; NONUNIFORMITY CORRECTION; DOSIMETRY; CALIBRATION;
D O I
10.1118/1.4939226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The new radiochromic film, GAFChromic EBT-XD, contains the same active material, lithium-10,12-pentacosadiynoate, as GAFChromic EBT3, but the crystalline form is different. This work investigates the effect of this change on the well-known lateral response artifact when EBT-XD film is digitized on a flatbed scanner. Methods: The dose response of a single production lot of EBT-XD was characterized by scanning an unexposed film plus a set of films exposed to doses between 2.5 and 50 Gy using 6 MV photons. To characterize the lateral response artifact, the authors used the unexposed film plus a subset of samples exposed to doses between 20 and 50 Gy. Digital images of these films were acquired at seven discrete lateral locations perpendicular to the scan direction on three Epson 10000XL scanners. Using measurements at the discrete lateral positions, the scanner responses were determined as a function of the lateral position of the film From the data for each scanner, a set of coefficients were derived whereby measured response values could be corrected to remove the effects of the lateral response artifact. The EBT-XD data were analyzed as in their previous work and compared to results reported for EBT3 in that paper. Results: For films scanned in the same orientation and having equal responses, the authors found that the lateral response artifact for EBT-XD and EBT3 films was remarkably similar. For both films, the artifact increases with increased net response. However, as EBT-XD is less sensitive than EBT3, a greater exposure dose is required to reach the same net response. On this basis, the lower sensitivity of EBT-XD relative to EBT3 results in less net response change for equal exposure and a reduction in the impact of the lateral response artifact. Conclusions: The shape of the crystalline active component in EBT-XD and EBT3 does not affect the fundamental existence of the lateral response artifact when the films are digitized on flatbed scanners. Owing its lower sensitivity, EBT-XD film requires higher dose to reach the same response as EBT3, resulting in lesser impact of the lateral response artifact. For doses >10 Gy, the slopes of the EBT-XD red and green channel dose response curves are greater than the corresponding ones for EBT3. For these two reasons, the authors prefer EBT-XD for doses exceeding about 10 Gy. 2016 American Association of Physicists in Medicine.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 50 条
  • [11] Gafchromic EBT-XD Film for Dose Profile Evaluation and Absolute Dose Measurement in High Dose Stereotactic Treatments
    Joseph, R.
    Hatzinikolaou, G.
    Kriminski, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E645 - E646
  • [12] Initial Characterization of the New EBT XD Gafchromic Film
    Grams, M.
    Gustafson, J.
    Long, K.
    de los Santos, L. Fong
    MEDICAL PHYSICS, 2015, 42 (06) : 3449 - 3449
  • [13] Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy
    Miura, Hideharu
    Ozawa, Shuichi
    Hosono, Fumika
    Sumida, Naoki
    Okazue, Toshiya
    Yamada, Kiyoshi
    Nagata, Yasushi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 312 - 322
  • [14] Evaluation of Gafchromic EBT-XD Film Using Vidar DosimetryPRO Advantage Red Scanner for SRS and SBRT QA
    Dumas, M.
    Wen, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 3119 - 3120
  • [15] Time Evolution of the Response of Irradiated EBT-XD Radiochromic Films
    Mulrow, D.
    Leon, Y.
    Darafsheh, A.
    Khan, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E311 - E311
  • [16] EXPERIMENTAL EVALUATION OF DOSIMETRIC CHARACTERIZATION OF GAFCHROMIC EBT3 AND EBT-XD FILMS FOR CLINICAL CARBON ION BEAMS
    Yonai, Shunsuke
    Arai, Chinatsu
    Shimoyama, Kaoru
    Fournier-Bidoz, Nathalie
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 314 - 318
  • [17] Growth kinetics of the EBT3 and EBT-XD films response in radiotherapy beams
    Momin, Shadab
    Khan, Rao
    Darafsheh, Arash
    OPTICS AND IONIZING RADIATION, 2020, 2020, 11224
  • [18] Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
    Khachonkham, Suphalak
    Dreindl, Ralf
    Heilemann, Gerd
    Lechner, Wolfgang
    Fuchs, Hermann
    Palmans, Hugo
    Georg, Dietmar
    Kuess, Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [19] A comparison between Gafchromic EBT3 and EBT-XD films for pre-treatment QA of SBRT/SRS plans
    Santos, T.
    Ventura, T.
    Capela, M.
    Mateus, J.
    Lopes, M. D. C.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1343 - S1344
  • [20] EBT-XD Gafchromic Films for Multiple Mets Intra-Cranial VMAT SRS Dosimetric Verification
    Hussain, A.
    Hudson, A.
    Ploquin, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 2952 - 2952