Validation of A&D UA-767 device for the self-measurement of blood pressure

被引:82
|
作者
Rogoza, AN [1 ]
Pavlova, TS [1 ]
Sergeeva, MV [1 ]
机构
[1] Dept New Diagnost Methods, Moscow 121552, Russia
关键词
A&D UA-767; self blood pressure measurement; validation; AAMI and BHS protocol;
D O I
10.1097/00126097-200008000-00006
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background The validation of self-measurement devices has been recommended. Automatic monitor A & D UA-767 (A&D Company, Ltd, Tokyo, Japan) is well known and widely used, but not tested according to the Association for Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) recommendations. Objective To perform a clinical validation for use by adults of the A&D UA-767 device according to the criteria of the AAMI and a modified BHS protocol. Methods The test concerned 101 subjects (57 men and 44 women) aged 15-85 years with arm circumferences of 22-39 cm, a systolic blood pressure (SBP) range of 89-206 mmHg, and a diastolic blood pressure (DBP) range of 53 - 122 mmHg. For each subject, three readings of the UA-767 were compared with simultaneous auscultatory measurements by two trained independent observers who used a mercury manometer and dual stethoscope. The results were graded according to the BHS (1990 and 1993) and AAMI recommendations. Results Observers showed close agreement, with mean differences of 1.1. +/- 2.4 mmHg for SEP and -0.7 +/- 2.0 mmHg for DBP. The proportion of Values agreeing to within 5, 10 and 15 mmHg were 93, 100, and 100% for SEP and 97, 100, and 100% for DBP for the two observers. The sphygmomanometer measurements were 132 +/- 24/79 +/- 14 mmHg (mean +/- SD). The average difference between the mercury sphygmomanometer and A&D UA-767 readings for SEP and DBP were, respectively, - 0.4 +/- 5.4 and -0.4 +/- 4.8 mmHg. The proportion of values agreeing to within 5,10, and 15 mmHg were 82, 94, and 98% for SEP and 80, 95, and 98% for DBP for the observers and device (A/A grade for BHS). Conclusions For an adult population, the A&D UA-767 device for the self-measurement of blood pressure satisfied the AAMI criteria, achieved a BHS grade of A/A and can therefore be recommended for monitoring blood pressure in home and clinical conditions by patients with mild-to-moderate arterial hypertension. (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [41] Reproducibility and cost of blood pressure self-measurement using the 'Loaned Self-measurement Equipment Model'
    Calvo-Vargas, C
    Rios, VP
    Troyo-Sanromán, R
    Grover-Paez, F
    BLOOD PRESSURE MONITORING, 2001, 6 (05) : 225 - 232
  • [42] VALIDATION OF THE WRIST AUTOMATIC DEVICE FOR SELF-MEASUREMENT OF BLOOD PRESSURE - THE TRAVEL CHECK - ACCORDING TO THE EUROPEAN SOCIETY OF HYPERTENSION PROTOCOL
    Germano, G.
    Pecchioli, V.
    Psimenos, A.
    Sarullo, F.
    Venditti, A.
    Asmar, R.
    JOURNAL OF HYPERTENSION, 2009, 27 : S352 - S352
  • [43] An Automated Blood Pressure Display for Self-Measurement in Patients With Chronic Kidney Disease (iHealth Track): Device Validation Study
    Mazoteras-Pardo, Victoria
    Becerro-De-Bengoa-Vallejo, Ricardo
    Elena Losa-Iglesias, Marta
    Lopez-Lopez, Daniel
    Calvo-Lobo, Cesar
    Rodriguez-Sanz, David
    Maria Martinez-Jimenez, Eva
    Palomo-Lopez, Patricia
    JMIR MHEALTH AND UHEALTH, 2020, 8 (04):
  • [44] Validation of the A&D BP UA-651 device with a wide-range cuff for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010
    Benetti, Elisabetta
    Fania, Claudio
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2015, 20 (03) : 164 - 167
  • [45] DETECTION OF NOCTURNAL HYPERTENSION BY SELF-MEASUREMENT OF BLOOD PRESSURE MEASUREMENT
    Ozono, Ryoji
    JOURNAL OF HYPERTENSION, 2023, 41 : E207 - E207
  • [46] Blood Pressure Self-Measurement in the Obstetric Waiting Room
    Wagner, Stefan
    Kamper, Christina H.
    Toftegaard, Thomas S.
    Bertelsen, Olav W.
    TELEMEDICINE AND E-HEALTH, 2013, 19 (11) : 872 - 874
  • [47] Devices for blood pressure self-measurement: Present and future
    Schmidt, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 13 - 19
  • [48] SELF-MEASUREMENT OF BLOOD-PRESSURE - ASSESSMENT OF EQUIPMENT
    MCKAY, DW
    CAMPBELL, NRC
    CHOCKALINGAM, A
    KU, L
    SMALL, C
    WASI, S
    CANADIAN JOURNAL OF CARDIOLOGY, 1995, 11 : H29 - H34
  • [49] Self-Measurement of Blood Pressure at Home in the Management of Hypertension
    Celis, Hilde
    Den Hond, Elly
    Staessen, Jan
    CLINICAL MEDICINE & RESEARCH, 2005, 3 (01) : 19 - 26
  • [50] Video training for blood-pressure self-measurement
    Postel-Vinay, N
    Chatellier, G
    Bobrie, G
    Donzel, M
    Plouin, PF
    Ménard, J
    JOURNAL OF HYPERTENSION, 2004, 22 : S159 - S160