Validation of A&D UA-767 device for the self-measurement of blood pressure

被引:82
|
作者
Rogoza, AN [1 ]
Pavlova, TS [1 ]
Sergeeva, MV [1 ]
机构
[1] Dept New Diagnost Methods, Moscow 121552, Russia
关键词
A&D UA-767; self blood pressure measurement; validation; AAMI and BHS protocol;
D O I
10.1097/00126097-200008000-00006
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background The validation of self-measurement devices has been recommended. Automatic monitor A & D UA-767 (A&D Company, Ltd, Tokyo, Japan) is well known and widely used, but not tested according to the Association for Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) recommendations. Objective To perform a clinical validation for use by adults of the A&D UA-767 device according to the criteria of the AAMI and a modified BHS protocol. Methods The test concerned 101 subjects (57 men and 44 women) aged 15-85 years with arm circumferences of 22-39 cm, a systolic blood pressure (SBP) range of 89-206 mmHg, and a diastolic blood pressure (DBP) range of 53 - 122 mmHg. For each subject, three readings of the UA-767 were compared with simultaneous auscultatory measurements by two trained independent observers who used a mercury manometer and dual stethoscope. The results were graded according to the BHS (1990 and 1993) and AAMI recommendations. Results Observers showed close agreement, with mean differences of 1.1. +/- 2.4 mmHg for SEP and -0.7 +/- 2.0 mmHg for DBP. The proportion of Values agreeing to within 5, 10 and 15 mmHg were 93, 100, and 100% for SEP and 97, 100, and 100% for DBP for the two observers. The sphygmomanometer measurements were 132 +/- 24/79 +/- 14 mmHg (mean +/- SD). The average difference between the mercury sphygmomanometer and A&D UA-767 readings for SEP and DBP were, respectively, - 0.4 +/- 5.4 and -0.4 +/- 4.8 mmHg. The proportion of values agreeing to within 5,10, and 15 mmHg were 82, 94, and 98% for SEP and 80, 95, and 98% for DBP for the observers and device (A/A grade for BHS). Conclusions For an adult population, the A&D UA-767 device for the self-measurement of blood pressure satisfied the AAMI criteria, achieved a BHS grade of A/A and can therefore be recommended for monitoring blood pressure in home and clinical conditions by patients with mild-to-moderate arterial hypertension. (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [31] Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to the International Protocol
    Stergiou, George S.
    Giovas, Periklis P.
    Gkinos, Charilaos P.
    Tzamouranis, Dimitris G.
    BLOOD PRESSURE MONITORING, 2008, 13 (01) : 37 - 42
  • [32] Measurement Adherence in the Blood Pressure Self-Measurement Room
    Wagner, Stefan
    Buus, Niels Henrik
    Jespersen, Bente
    Ahrendt, Peter
    Bertelsen, Olav W.
    Toftegaard, Thomas S.
    TELEMEDICINE AND E-HEALTH, 2013, 19 (11) : 826 - 833
  • [33] VALIDATION OF A SELF BLOOD-PRESSURE MEASUREMENT DEVICE
    FOUQUERAY, B
    JULIEN, J
    PAGNY, JY
    JEUNEMAITRE, X
    SASSANO, P
    BATTAGLIA, C
    PLOUIN, PF
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1988, 10 (05) : 907 - 907
  • [34] Self-measurement of blood pressure in the office and at home
    Myers, MG
    Parati, G
    JOURNAL OF HYPERTENSION, 2003, 21 (12) : 2223 - 2225
  • [35] RECOMMENDATIONS ON SELF-MEASUREMENT OF BLOOD-PRESSURE
    BASS, MJ
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1988, 138 (12) : 1093 - 1096
  • [36] COMPUTERIZED SELF-MEASUREMENT OF BLOOD-PRESSURE
    HACKETT, GI
    MOORE, S
    HARRISON, PW
    DAVIES, M
    PRACTITIONER, 1984, 228 (1392) : 591 - 593
  • [37] Reporting bias in self-measurement of blood pressure
    Myers, MG
    BLOOD PRESSURE MONITORING, 2001, 6 (04) : 181 - 183
  • [38] User procedure for self-measurement of blood pressure
    Mengden, T
    Chamontin, B
    Chau, NP
    Gamiz, JLP
    Chanudet, X
    BLOOD PRESSURE MONITORING, 2000, 5 (02) : 111 - 129
  • [39] Dear Colleagues the Self-Measurement of Blood Pressure
    Eckert, S.
    DIABETES STOFFWECHSEL UND HERZ, 2011, 20 (04): : 263 - 264
  • [40] Self-measurement of blood pressure at home: Is it reliable?
    Dilek, Melda
    Adibelli, Zelal
    Aydogdu, Turkan
    Koksal, Ali Riza
    Cakar, Burcu
    Akpolat, Tekin
    BLOOD PRESSURE, 2008, 17 (01) : 34 - 41