Flow injection differential potentiometric determination of lysine by using a lysine biosensor

被引:28
|
作者
García-Villar, N [1 ]
Saurina, J [1 ]
Hernández-Cassou, S [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
differential potentiometry; lysine biosensor; ammonium electrode; flow injection analysis; lysine analysis; stopped-flow; partial least squares regression;
D O I
10.1016/S0003-2670(02)01426-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a method for the determination of lysine based on a flow injection (FI) differential potentiometry system. The flow injection manifold is composed of a support electrolyte solution channel and a water channel acting as a carrier into which the sample solution is injected. The lysine biosensor was consisted of lysine oxidase chemically immobilized on a nylon membrane and attached to an all-solid-state ammonium electrode. A circular ammonium electrode was used as a reference. Hence, the possible interference of endogenous ammonium can be partly corrected by differential potentiometry. In order to increase the sensitivity of the response, the reaction was kinetically developed following a stopped-flow method. As a result, the sensitivity increased from 20 to 40 mV per decade when comparing the FI and the stopped-flow values. Furthermore, the peak-to-peak stopped-flow signals generated can be used as a more selective analytical response for lysine. The quantification of lysine in mixture samples containing small amounts of ammonium can be achieved with an acceptable accuracy, with prediction errors lower than 4%. However, when the ammonium concentration exceeded the lysine concentration, multivariate calibration with non-linear partial least squares (PLS) regression was needed to improve the lysine quantification, with an overall prediction error around 10%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [1] Selective determination of lysine in mozzarella cheese using a novel potentiometric biosensor
    Piedra, Felipe Jadan
    Rojas, Cristian
    Castro, Gisela Beatriz Latorre
    Alvarado, Pedro Maldonado
    FOOD BIOTECHNOLOGY, 2023, 37 (01) : 41 - 53
  • [2] Liquid chromatographic determination of lysine by potentiometric detection with a biosensor
    García-Villar, N
    Saurina, J
    Hernández-Cassou, S
    ANALYTICAL LETTERS, 2002, 35 (08) : 1313 - 1325
  • [3] Flow injection chemiluminescence determination of ornithine and sequential determination of ornithine and lysine by using immobilized lysine oxidase
    Almuaibed, AM
    Townshend, A
    ANALYTICA CHIMICA ACTA, 1999, 388 (03) : 339 - 343
  • [4] FLOW-INJECTION AMPEROMETRIC BIOSENSOR BASED ON IMMOBILIZED L-LYSINE-ALPHA-OXIDASE FOR L-LYSINE DETERMINATION
    SIMONIAN, AL
    BADALIAN, IE
    BEREZOV, TT
    SMIRNOVA, IP
    KHADUEV, SH
    ANALYTICAL LETTERS, 1994, 27 (15) : 2849 - 2860
  • [5] A novel potentiometric biosensor for determination of L-lysine in commercial pharmaceutical L-lysine tablet and capsule
    Yarar, Saniye
    Karakus, Emine
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2016, 44 (02) : 485 - 490
  • [6] Potentiometric biosensor for lysine analysis based on a chemically immobilized lysine oxidase membrane
    Saurina, J
    Hernández-Cassou, S
    Fàbregas, E
    Alegret, S
    ANALYTICA CHIMICA ACTA, 1998, 371 (01) : 49 - 56
  • [7] BIOSENSOR FOR THE DETERMINATION OF L-LYSINE
    VRBOVA, E
    MAREK, M
    RALYS, E
    ANALYTICA CHIMICA ACTA, 1992, 270 (01) : 131 - 136
  • [8] Amperometric determination of lysine using a lysine oxidase biosensor based on rigid-conducting composites
    Saurina, J
    Hernández-Cassou, S
    Alegret, S
    Fàbregas, E
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (02): : 211 - 220
  • [9] CHEMILUMINOMETRIC L-LYSINE DETERMINATION WITH IMMOBILIZED LYSINE OXIDASE BY FLOW-INJECTION ANALYSIS
    PREUSCHOFF, F
    SPOHN, U
    WEBER, E
    UNVERHAU, K
    MOHR, KH
    ANALYTICA CHIMICA ACTA, 1993, 280 (02) : 185 - 189
  • [10] Determination of lysine in pharmaceutical samples containing endogenous ammonium ions by using a lysine oxidase biosensor based on an all-solid-state potentiometric ammonium electrode
    Saurina, J
    Hernández-Cassou, S
    Alegret, S
    Fàbregas, E
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (01): : 67 - 75