Flow injection differential potentiometric determination of lysine by using a lysine biosensor

被引:28
|
作者
García-Villar, N [1 ]
Saurina, J [1 ]
Hernández-Cassou, S [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
differential potentiometry; lysine biosensor; ammonium electrode; flow injection analysis; lysine analysis; stopped-flow; partial least squares regression;
D O I
10.1016/S0003-2670(02)01426-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a method for the determination of lysine based on a flow injection (FI) differential potentiometry system. The flow injection manifold is composed of a support electrolyte solution channel and a water channel acting as a carrier into which the sample solution is injected. The lysine biosensor was consisted of lysine oxidase chemically immobilized on a nylon membrane and attached to an all-solid-state ammonium electrode. A circular ammonium electrode was used as a reference. Hence, the possible interference of endogenous ammonium can be partly corrected by differential potentiometry. In order to increase the sensitivity of the response, the reaction was kinetically developed following a stopped-flow method. As a result, the sensitivity increased from 20 to 40 mV per decade when comparing the FI and the stopped-flow values. Furthermore, the peak-to-peak stopped-flow signals generated can be used as a more selective analytical response for lysine. The quantification of lysine in mixture samples containing small amounts of ammonium can be achieved with an acceptable accuracy, with prediction errors lower than 4%. However, when the ammonium concentration exceeded the lysine concentration, multivariate calibration with non-linear partial least squares (PLS) regression was needed to improve the lysine quantification, with an overall prediction error around 10%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [31] Flow injection potentiometric determination of dothiepin hydrochloride
    Ghani, NTA
    El-Nashar, RM
    Bioumy, AA
    ANALYTICAL LETTERS, 2004, 37 (15) : 3237 - 3254
  • [32] Flow injection potentiometric determination of amitriptyline hydrochloride
    El-Nashar, RM
    Abdel Ghani, NT
    Bioumy, AA
    MICROCHEMICAL JOURNAL, 2004, 78 (02) : 107 - 113
  • [33] Flow injection potentiometric determination of amantadine HCl
    Abdel-Ghani, NT
    Shoukry, AF
    Hussein, SH
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 601 - 611
  • [34] Flow injection potentiometric determination of pipazethate hydrochloride
    Abdel-Ghani, NT
    Shoukry, AF
    El Nashar, RM
    ANALYST, 2001, 126 (01) : 79 - 85
  • [35] DETERMINATION OF LYSINE IN PROTEIN HYDROLYZATES USING LYSINE DECARBOXYLASE FROM SALMONELLA-HADAR
    KOTT, Y
    LICHTENSTEIN, N
    ANALYTICA CHIMICA ACTA, 1960, 22 (04) : 401 - 403
  • [36] DETERMINATION OF LYSINE AND ORNITHINE USING ACID NINHYDRIN
    DAVIES, RL
    JOURNAL OF CHROMATOGRAPHY, 1972, 71 (03): : 564 - &
  • [37] Development of an interferent free amperometric biosensor for determination of L-lysine in food
    Kelly, SC
    O'Connell, PJ
    O'Sullivan, CK
    Guilbault, GG
    ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) : 111 - 119
  • [38] FLUORIMETRIC DETERMINATION OF LYSINE
    ROTH, M
    JEANNERET, L
    HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1972, 353 (10): : 1607 - 1609
  • [39] THE COLORIMETRIC DETERMINATION OF LYSINE
    KIBRICK, AC
    ARCHIVES OF BIOCHEMISTRY, 1949, 20 (01): : 22 - 24
  • [40] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Preeyanut Butmee
    Sarawut Prasertsri
    Saichol Pimmongkol
    Gamolwan Tumcharern
    Albana Veseli
    Eda Mehmeti
    Kurt Kalcher
    Anchalee Samphao
    Monatshefte für Chemie - Chemical Monthly, 2017, 148 : 635 - 644