Flow injection differential potentiometric determination of lysine by using a lysine biosensor

被引:28
|
作者
García-Villar, N [1 ]
Saurina, J [1 ]
Hernández-Cassou, S [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
differential potentiometry; lysine biosensor; ammonium electrode; flow injection analysis; lysine analysis; stopped-flow; partial least squares regression;
D O I
10.1016/S0003-2670(02)01426-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a method for the determination of lysine based on a flow injection (FI) differential potentiometry system. The flow injection manifold is composed of a support electrolyte solution channel and a water channel acting as a carrier into which the sample solution is injected. The lysine biosensor was consisted of lysine oxidase chemically immobilized on a nylon membrane and attached to an all-solid-state ammonium electrode. A circular ammonium electrode was used as a reference. Hence, the possible interference of endogenous ammonium can be partly corrected by differential potentiometry. In order to increase the sensitivity of the response, the reaction was kinetically developed following a stopped-flow method. As a result, the sensitivity increased from 20 to 40 mV per decade when comparing the FI and the stopped-flow values. Furthermore, the peak-to-peak stopped-flow signals generated can be used as a more selective analytical response for lysine. The quantification of lysine in mixture samples containing small amounts of ammonium can be achieved with an acceptable accuracy, with prediction errors lower than 4%. However, when the ammonium concentration exceeded the lysine concentration, multivariate calibration with non-linear partial least squares (PLS) regression was needed to improve the lysine quantification, with an overall prediction error around 10%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [41] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Butmee, Preeyanut
    Prasertsri, Sarawut
    Pimmongkol, Saichol
    Tumcharern, Gamolwan
    Veseli, Albana
    Mehmeti, Eda
    Kalcher, Kurt
    Samphao, Anchalee
    MONATSHEFTE FUR CHEMIE, 2017, 148 (04): : 635 - 644
  • [42] AN OPTICAL BIOSENSOR FOR LYSINE BASED ON THE USE OF LYSINE DECARBOXYLASE AND A CADAVERINE-SENSITIVE MEMBRANE
    LI, H
    HE, HR
    WOLFBEIS, OS
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (10): : 725 - 732
  • [43] FLOW-INJECTION DETERMINATION OF NITRATE IN VEGETABLES USING A TUBULAR POTENTIOMETRIC DETECTOR
    LIMA, JLFC
    RANGEL, AOSS
    SOUTO, MRS
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (03) : 704 - 707
  • [44] Determination of citric acid in soft drinks using flow injection with potentiometric detection
    José L. F. C. Lima
    C. Delerue-Matos
    M. Carmo
    M. C. V. F. Vaz
    Jeanine Silva
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 266 - 269
  • [45] POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF SUGARS USING A METALLIC COPPER ELECTRODE
    ALEXANDER, PW
    HADDAD, PR
    TROJANOWICZ, M
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (16): : 1953 - 1978
  • [46] Determination of citric acid in soft drinks using flow injection with potentiometric detection
    Lima, JLFC
    Delerue-Matos, C
    Carmo, M
    Vaz, VF
    Silva, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (03): : 266 - 269
  • [47] Bioavailability determination of lysine sulfate and lysine HCI with broiler chickens
    Neme, R
    Albino, LFT
    Rostagno, HS
    Rodrigueiro, RJB
    Toledo, RS
    REVISTA BRASILEIRA DE ZOOTECNIA-BRAZILIAN JOURNAL OF ANIMAL SCIENCE, 2001, 30 (06): : 1750 - 1759
  • [48] A SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF LYSINE UTILIZING BACTERIAL LYSINE DECARBOXYLASE
    DICKERMAN, HW
    CARTER, ML
    ANALYTICAL BIOCHEMISTRY, 1962, 3 (03) : 195 - &
  • [49] LYSINE SPECIFIC ENZYME ELECTRODE FOR DETERMINATION OF LYSINE IN GRAINS AND FOODSTUFFS
    WHITE, WC
    GUILBAULT, GG
    ANALYTICAL CHEMISTRY, 1978, 50 (11) : 1481 - 1486
  • [50] Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system
    José L. F. C. Lima
    M. C. B. S. M. Montenegro
    Ana P. M. M. O. Pinto
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 353 - 357