CHEMILUMINOMETRIC L-LYSINE DETERMINATION WITH IMMOBILIZED LYSINE OXIDASE BY FLOW-INJECTION ANALYSIS

被引:34
|
作者
PREUSCHOFF, F
SPOHN, U
WEBER, E
UNVERHAU, K
MOHR, KH
机构
[1] UNIV HALLE,INST BIOTECHNOL,WEINBERGWEG 16A,O-4050 HALLE,GERMANY
[2] UNIV HALLE,DEPT MED,INST BIOCHEM,O-4020 HALLE,GERMANY
[3] UNIV HALLE,INST MICROBIOL,O-4050 HALLE,GERMANY
关键词
CHEMILUMINESCENCE; ENZYMATIC METHODS; FLOW INJECTION; LYSINE;
D O I
10.1016/0003-2670(93)85120-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymatic flow-injection procedure for the determination of L-lysine was developed. A lysine oxidase reactor is combined with a fibre-optic hydrogen peroxide detector. Hydrogen peroxide detection is based on the peroxidase-catalysed luminol reaction. The chemiluminescent light is detected by a photomultiplier. L-Lysine can be determined in the range 10-1000 muM. A sampling rate of up to 90 h-1 can be achieved. The whole sensing assay works for more than 1 month. The double logarithmic graph of the peak signal height vs. the lysine concentration is linear, the slope being larger than unity (r2 = 0.991, n = 4).
引用
收藏
页码:185 / 189
页数:5
相关论文
共 50 条
  • [1] FLOW-INJECTION AMPEROMETRIC BIOSENSOR BASED ON IMMOBILIZED L-LYSINE-ALPHA-OXIDASE FOR L-LYSINE DETERMINATION
    SIMONIAN, AL
    BADALIAN, IE
    BEREZOV, TT
    SMIRNOVA, IP
    KHADUEV, SH
    ANALYTICAL LETTERS, 1994, 27 (15) : 2849 - 2860
  • [2] ENZYMATIC DETERMINATION OF L-LYSINE BY FLOW-INJECTION TECHNIQUES
    POHLMANN, A
    STAMM, WW
    KUSAKABE, H
    KULA, MR
    ANALYTICA CHIMICA ACTA, 1990, 235 (02) : 329 - 335
  • [3] Chemiluminometric sensor for simultaneous determination of L-glutamate and L-lysine with immobilized oxidases in a flow injection system
    Kiba, N
    Miwa, T
    Tachibana, M
    Tani, K
    Koizumi, H
    ANALYTICAL CHEMISTRY, 2002, 74 (06) : 1269 - 1274
  • [4] Selective biosensing of L-lysine by a low-temperature flow-injection technique using an immobilized lysine oxidase reactor
    Chen, RLC
    Lee, MH
    Matsumoto, K
    ANALYTICAL SCIENCES, 1996, 12 (01) : 87 - 90
  • [5] MANOMETRIC DETERMINATION OF L-LYSINE AND D-LYSINE BY BACTERIAL L-LYSINE OXIDASE AND ITS RACEMASE
    ICHIHARA, A
    OGATA, M
    SUDA, M
    JOURNAL OF BIOCHEMISTRY, 1960, 48 (03): : 421 - 424
  • [6] SENSITIVE AND SIMPLE METHODS FOR DETERMINATION OF L-LYSINE WITH L-LYSINE ALPHA-OXIDASE
    KUSAKABE, H
    KODAMA, K
    KUNINAKA, A
    YOSHINO, H
    SODA, K
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1979, 43 (08): : 1749 - 1752
  • [7] Flow injection chemiluminescence determination of ornithine and sequential determination of ornithine and lysine by using immobilized lysine oxidase
    Almuaibed, AM
    Townshend, A
    ANALYTICA CHIMICA ACTA, 1999, 388 (03) : 339 - 343
  • [8] APPROACH FOR THE SIMULTANEOUS FLOW-INJECTION DETERMINATION OF L-TYROSINE AND L-LYSINE BASED ON THE ENZYME REACTORS
    MATSUMOTO, K
    GAO, LY
    OSAJIMA, Y
    JOURNAL OF THE FACULTY OF AGRICULTURE KYUSHU UNIVERSITY, 1994, 38 (3-4): : 207 - 212
  • [9] Flow injection amperometric and chemiluminescence individual and simultaneous determination of lysine and glucose with immobilized lysine oxidase and glucose oxidase
    Almuaibed, AM
    Townshend, A
    ANALYTICA CHIMICA ACTA, 1997, 338 (1-2) : 149 - 154
  • [10] Amperometric L-lysine determination biosensor amplified with L-lysine oxidase nanoparticles and graphene oxide nanoparticles
    Nohwal, Bhawna
    Chaudhary, Reeti
    Pundir, C. S.
    PROCESS BIOCHEMISTRY, 2020, 97 : 57 - 63