Dose reduction in full-field digital mammography - An anthropomorphic breast phantom study.

被引:0
|
作者
Obenauer, S [1 ]
Hermann, KP [1 ]
Grabbe, E [1 ]
机构
[1] Univ Gottingen, Dept Diagnost Radiol, D-37075 Gottingen, Germany
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The goal of this study was to evaluate the potential of radiation dose reduction in full-field digital mammography (FFDM) compared to screen-film mammography (SFM). An anthropomorphic breast phantom with superimposed microcalcifications (50-20mum) was used to evaluate the detectability of microcalcifications. Images were exposed automatically (AEC mode) using a Mo/Mo anode-filter-combination (protocol A). Dose reduction in digital mammography was achieved by using protocol B with Mo/Rh and protocol C with Rh/Rh. The detectability of microcalcifications was assessed by 3 well-experienced readers with a confidence level ranging from I to 5. A receiver operating characteristic (ROC) analysis was performed. Compared to screen-film mammography the digital mammography system allows an equivalent detection rate for microcalcifications at a lower radiation exposure.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 50 条
  • [1] Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study
    Obenauer, S
    Hermann, KP
    Grabbe, E
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (907): : 478 - 482
  • [2] Full-field digital mammography: An anthropomorphic phantom study for the detectability of simulated microcalcifications
    Obenauer, S
    Schorn, C
    Hermann, K
    Funke, M
    Fischer, U
    Grabbe, EH
    [J]. RADIOLOGY, 2000, 217 : 200 - 200
  • [3] Dose reduction in Full-Field Digital Electromagnetic Radiation Mammography using Noise reduction Method: Phantom Study
    Choi, Seokyoon
    Seo, Jeongmin
    [J]. JOURNAL OF MAGNETICS, 2019, 24 (04) : 744 - 751
  • [4] Dose Reduction in Automatic Optimization Parameter of Full Field Digital Mammography: Breast Phantom Study
    Ko, Myung-Su
    Kim, Hak Hee
    Cha, Joo Hee
    Shin, Hee Jung
    Kim, Jeoung Hyun
    Kim, Min Jeong
    [J]. JOURNAL OF BREAST CANCER, 2013, 16 (01) : 90 - 96
  • [5] Digital luminescence mammography (CR) versus full-field digital mammography (DR): A phantom study
    Schulz-Wendtland, RW
    Aichinger, UG
    Lell, MM
    Kuchar, I
    Tartsch, M
    Bautz, WA
    [J]. RADIOLOGY, 2002, 225 : 416 - 417
  • [6] Threshold in breast compression reduction for full-field digital mammography and digital breast tomosynthesis
    Afandy, A. N.
    Tori, M. B.
    Bintalib, S. O.
    Soh, B. L. P.
    [J]. RADIOGRAPHY, 2024, 30 (01) : 217 - 225
  • [7] Evaluation of the exposure dose reduction in full-field digital mammography system
    Tanigoshi, M
    Kobayashi, H
    Uchiyama, N
    Suzuki, T
    Kumazaki, T
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 149 - 151
  • [8] Dose reduction through gridless technique in digital full-field mammography
    Diekmann, F
    Diekmann, S
    Berzeg, S
    Bick, U
    Fischer, T
    Hamm, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 769 - 774
  • [9] Evaluation of the potential in radiation dose reduction for full-field digital mammography
    Kasch, Kay-Uwe
    Moftah, Belal A.
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (02) : 87 - 98
  • [10] Full-field digital mammography in comparison to screen-film mammography - A phantom study
    Obenauer, S
    Schorn, C
    Funke, M
    Fischer, U
    Grabbe, E
    Hermann, KP
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 499 - 503