Dose reduction in full-field digital mammography - An anthropomorphic breast phantom study.

被引:0
|
作者
Obenauer, S [1 ]
Hermann, KP [1 ]
Grabbe, E [1 ]
机构
[1] Univ Gottingen, Dept Diagnost Radiol, D-37075 Gottingen, Germany
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The goal of this study was to evaluate the potential of radiation dose reduction in full-field digital mammography (FFDM) compared to screen-film mammography (SFM). An anthropomorphic breast phantom with superimposed microcalcifications (50-20mum) was used to evaluate the detectability of microcalcifications. Images were exposed automatically (AEC mode) using a Mo/Mo anode-filter-combination (protocol A). Dose reduction in digital mammography was achieved by using protocol B with Mo/Rh and protocol C with Rh/Rh. The detectability of microcalcifications was assessed by 3 well-experienced readers with a confidence level ranging from I to 5. A receiver operating characteristic (ROC) analysis was performed. Compared to screen-film mammography the digital mammography system allows an equivalent detection rate for microcalcifications at a lower radiation exposure.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 50 条
  • [41] Comparison of full-field digital mammography with CR mammography
    Uchiyama, N
    Kobayashi, H
    Tajima, H
    Machida, M
    Kumazaki, T
    Moriyama, N
    [J]. RADIOLOGY, 2002, 225 : 119 - 119
  • [42] Dose comparison between screen/film and full-field digital mammography
    Gennaro, Gisella
    di Maggio, Cosimo
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (11) : 2559 - 2566
  • [43] Comparing Diagnostic Performance of Digital Breast Tomosynthesis and Full-Field Digital Mammography
    Cochon, Laila R.
    Giess, Catherine S.
    Khorasani, Ramin
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (08) : 999 - 1003
  • [44] Average glandular dose with full-field digital mammography - Clinical results
    Hermann, KP
    Kehbel, S
    Obenauer, S
    Fischer, U
    Grabbe, E
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 502 - 504
  • [45] Indices for the evaluation of glandular dose heterogeneity in full-field digital mammography
    Shinohara, Sae
    Araki, Fujio
    Maeda, Megumi
    Okamoto, Rumi
    Nakamura, Mai
    Higashida, Yoshiharu
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1429 - 1443
  • [46] Grid removal and impact on population dose in full-field digital mammography
    Gennaro, Gisella
    Katz, Luc
    Souchay, Henri
    Klausz, Remy
    Alberelli, Claudio
    di Maggio, Cosimo
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 547 - 555
  • [47] Dose comparison between screen/film and full-field digital mammography
    Gisella Gennaro
    Cosimo di Maggio
    [J]. European Radiology, 2006, 16 : 2559 - 2566
  • [48] Comparison of full-field digital and screen-film mammography dose
    Schueler, B.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2005 - 2005
  • [49] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    SJ Connor
    YY Lim
    C Tate
    H Entwistle
    J Morris
    S Whiteside
    J Sergeant
    M Wilson
    U Beetles
    C Boggis
    F Gilbert
    S Astley
    [J]. Breast Cancer Research, 14
  • [50] A Multisite Study of a Breast Density Deep Learning Model for Full-Field Digital Mammography and Synthetic Mammography
    Matthews, Thomas P.
    Singh, Sadanand
    Mombourquette, Brent
    Su, Jason
    Shah, Meet P.
    Pedemonte, Stefano
    Long, Aaron
    Maffit, David
    Gurney, Jenny
    Hoil, Rodrigo Morales
    Ghare, Nikita
    Smith, Douglas
    Moore, Stephen M.
    Marks, Susan C.
    Wahl, Richard L.
    [J]. RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2021, 3 (01)