Threshold in breast compression reduction for full-field digital mammography and digital breast tomosynthesis

被引:0
|
作者
Afandy, A. N. [1 ,5 ]
Tori, M. B. [2 ]
Bintalib, S. O. [3 ]
Soh, B. L. P. [4 ]
机构
[1] Ng Teng Fong Gen Hosp, Dept Radiol, Singapore, Singapore
[2] Tan Tock Seng Hosp, Dept Diagnost Radiol, Singapore, Singapore
[3] Natl Canc Ctr, Div Oncol Imaging, Singapore, Singapore
[4] Singapore Inst Technol, Hlth & Social Sci, Singapore, Singapore
[5] Ng Teng Fong Gen Hosp, Dept Radiol, 1 Jurong East St 21, Singapore 609606, Singapore
关键词
Digital mammography; Digital breast tomosynthesis; Breast compression; Mass conspicuity; Microcalcification conspicuity; Breast dosimetry; IMAGE QUALITY; MONTE-CARLO; CANCER; FORCE; CONSPICUOUSNESS; GUIDELINES; MASS;
D O I
10.1016/j.radi.2023.11.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Breast compression is essential in mammography to improve image quality and reduce radiation dose. However, it can cause discomfort or even pain in women which could discourage them from attending future mammography examinations. Therefore, this study aims to explore the maximum reduction in breast compression in full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) that is achievable without impacting on image quality and dose. Methods: Ten compression force (CF) levels (20N-110N, with 10N intervals) were assessed on Siemens MAMMOMAT Inspiration with Nuclear Associates 18-228 phantom. Imaging was carried out in craniocaudal projection using Automatic Exposure Control at 28 kVp with a Tungsten/Rhodium anode/filter combination, and at 50 degrees sweep angle for DBT. Using ImageJ software, image quality of the acquired mammograms and central tomosynthesis slices were examined based on mass conspicuity (MC) and microcalcification conspicuity (MicroC). Entrance skin dose (ESD) and mean glandular dose (MGD) were recorded from Digital Imaging and Communication in Medicine image header. Linear regression was performed to examine the relationship between CF with ESD, MGD, MC and MicroC. Differences in image quality and radiation dose were assessed with one-way analysis of variance and Kruskal-Wallis H test.Results: Significant correlations were noted between CF with ESD and MicroC for FFDM and DBT, with DBT also demonstrating associations with MGD and MC. No significant differences were observed for ESD, MGD, MC and MicroC when CF was reduced to 40N and 80N in FFDM and DBT respectively.Conclusion: This study demonstrated that CF can be reduced as low as 40N and 80N in FFDM and DBT respectively, without significant impact on image quality and radiation dose.Implications for practice: Reduced mammographic compression may reduce discomfort or pain in women, which may improve attendance rate in breast screening programmes. Findings from this study will provide reference for future work examining breast compression in mammography.(c) 2023 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [1] Invasive breast cancer: Digital breast tomosynthesis versus full-field digital mammography
    Hwang, Esther
    Szabo, Janet
    Mehta, Anita
    Margolies, Laurie
    [J]. APPLIED RADIOLOGY, 2016, 45 (12) : 32 - 34
  • [2] Comparing Diagnostic Performance of Digital Breast Tomosynthesis and Full-Field Digital Mammography
    Cochon, Laila R.
    Giess, Catherine S.
    Khorasani, Ramin
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (08) : 999 - 1003
  • [3] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    Connor, S. J.
    Lim, Y. Y.
    Tate, C.
    Entwistle, H.
    Morris, J.
    Whiteside, S.
    Sergeant, J.
    Wilson, M.
    Beetles, U.
    Boggis, C.
    Gilbert, F.
    Astley, S.
    [J]. BREAST CANCER RESEARCH, 2012, 14
  • [4] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    SJ Connor
    YY Lim
    C Tate
    H Entwistle
    J Morris
    S Whiteside
    J Sergeant
    M Wilson
    U Beetles
    C Boggis
    F Gilbert
    S Astley
    [J]. Breast Cancer Research, 14
  • [5] UTILIZATION AND COSTS OF DIGITAL BREAST TOMOSYNTHESIS OR BREAST ULTRASOUND IN CONJUNCTION WITH FULL-FIELD DIGITAL MAMMOGRAPHY
    Bonafede, M. M.
    Miller, J. D.
    Dabbous, F.
    Pohlman, S. K.
    Troeger, K. A.
    [J]. VALUE IN HEALTH, 2017, 20 (05) : A243 - A244
  • [6] A comparison between digital breast tomosynthesis and full-field digital mammography for the detection of breast cancers
    Woo Jung Choi
    Hak Hee Kim
    Sun Young Lee
    Eun Young Chae
    Hee Jung Shin
    Joo Hee Cha
    Byung Ho Son
    Sei Hyun Ahn
    Young-Wook Choi
    [J]. Breast Cancer, 2016, 23 : 886 - 892
  • [7] A comparison between digital breast tomosynthesis and full-field digital mammography for the detection of breast cancers
    Choi, Woo Jung
    Kim, Hak Hee
    Lee, Sun Young
    Chae, Eun Young
    Shin, Hee Jung
    Cha, Joo Hee
    Son, Byung Ho
    Ahn, Sei Hyun
    Choi, Young-Wook
    [J]. BREAST CANCER, 2016, 23 (06) : 886 - 892
  • [8] Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis
    McDonald, Elizabeth S.
    McCarthy, Anne Marie
    Akhtar, Amana L.
    Synnestvedt, Marie B.
    Schnall, Mitchell
    Conant, Emily F.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1143 - 1148
  • [9] Comparison of full-field digital mammography and digital breast tomosynthesis in ultrasonography-detected breast cancers
    Nam, Kyung Jin
    Han, Boo-Kyung
    Ko, Eun Sook
    Choi, Ji Soo
    Ko, Eun Young
    Jeong, Dong Wook
    Choo, Ki Seok
    [J]. BREAST, 2015, 24 (05): : 649 - 655
  • [10] Assessment of extent of breast cancer: Comparison between digital breast tomosynthesis and full-field digital mammography
    Mun, H. S.
    Kim, H. H.
    Shin, H. J.
    Cha, J. H.
    Ruppel, P. L.
    Oh, H. Y.
    Chae, E. Y.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (12) : 1254 - 1259