Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study

被引:25
|
作者
Obenauer, S [1 ]
Hermann, KP [1 ]
Grabbe, E [1 ]
机构
[1] Univ Gottingen, Dept Radiol, D-37075 Gottingen, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2003年 / 76卷 / 907期
关键词
D O I
10.1259/bjr/67597156
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the potential for radiation dose reduction by using other beam qualities in full-field digital mammography (FFDM) compared with screen-film mammography (SFM). FFDM was performed using an amorphous silicon detector with a caesium iodide scintillator layer (Senographe 2000D, GE, Milwaukee, USA). SFM was performed using a state-of-the-art conventional system (Senographe DMR, GE, Milwaukee, USA) with a dedicated screen-film combination. An anthropomorphic breast phantom with superimposed microcalcifications (50-200 mum) was used to evaluate the detectability of microcalcifications. Contact mammograms and magnification views (m=1.8) performed with both the digital and the screen-film system were compared. Images were exposed automatically. Molybdenum/Molybdenum (Mo/Mo) anode-filter combination, 28 kVp and 63 mAs were selected by the automatic optimization of parameters (AOP) of the conventional system. This exposure protocol (protocol A) was also used as baseline for the digital system. Dose reduction in digital mammography was achieved by using protocol B with Mo/Rh and 31 kVp and protocol C with Rh/Rh and 32 kVp. The detectability of microcalcifications was assessed by 3 experienced readers with a confidence level ranging from 1 to 5. A receiver operating characteristic (ROC) analysis was performed. In protocol A the area under the ROC-curve (A(z)) for contact views performed by the screen-film system was 0.64 and for those performed with the FFDM system 0.68. The A(z) values were 0.74 in protocol B and 0.65 in protocol C for the digital system. For the conventional and digital magnification views A(z) values were 0.71 and 0.79, respectively. For protocol B the A(z) value was 0.81 and for protocol C it was 0.76. There is no statistically significant difference in the A(z) values for the different protocols in digital mammography and no significant difference from the screen-film system. A potential for dose reduction by using other beam qualities seems to be possible with this digital system.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [1] Dose reduction in full-field digital mammography - An anthropomorphic breast phantom study.
    Obenauer, S
    Hermann, KP
    Grabbe, E
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 145 - 148
  • [2] Full-field digital mammography: An anthropomorphic phantom study for the detectability of simulated microcalcifications
    Obenauer, S
    Schorn, C
    Hermann, K
    Funke, M
    Fischer, U
    Grabbe, EH
    [J]. RADIOLOGY, 2000, 217 : 200 - 200
  • [3] Dose reduction in Full-Field Digital Electromagnetic Radiation Mammography using Noise reduction Method: Phantom Study
    Choi, Seokyoon
    Seo, Jeongmin
    [J]. JOURNAL OF MAGNETICS, 2019, 24 (04) : 744 - 751
  • [4] Dose Reduction in Automatic Optimization Parameter of Full Field Digital Mammography: Breast Phantom Study
    Ko, Myung-Su
    Kim, Hak Hee
    Cha, Joo Hee
    Shin, Hee Jung
    Kim, Jeoung Hyun
    Kim, Min Jeong
    [J]. JOURNAL OF BREAST CANCER, 2013, 16 (01) : 90 - 96
  • [5] Digital luminescence mammography (CR) versus full-field digital mammography (DR): A phantom study
    Schulz-Wendtland, RW
    Aichinger, UG
    Lell, MM
    Kuchar, I
    Tartsch, M
    Bautz, WA
    [J]. RADIOLOGY, 2002, 225 : 416 - 417
  • [6] Dose reduction through gridless technique in digital full-field mammography
    Diekmann, F
    Diekmann, S
    Berzeg, S
    Bick, U
    Fischer, T
    Hamm, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 769 - 774
  • [7] Evaluation of the exposure dose reduction in full-field digital mammography system
    Tanigoshi, M
    Kobayashi, H
    Uchiyama, N
    Suzuki, T
    Kumazaki, T
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 149 - 151
  • [8] Threshold in breast compression reduction for full-field digital mammography and digital breast tomosynthesis
    Afandy, A. N.
    Tori, M. B.
    Bintalib, S. O.
    Soh, B. L. P.
    [J]. RADIOGRAPHY, 2024, 30 (01) : 217 - 225
  • [9] Full-field digital mammography in comparison to screen-film mammography - A phantom study
    Obenauer, S
    Schorn, C
    Funke, M
    Fischer, U
    Grabbe, E
    Hermann, KP
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 499 - 503
  • [10] Evaluation of the potential in radiation dose reduction for full-field digital mammography
    Kasch, Kay-Uwe
    Moftah, Belal A.
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (02) : 87 - 98