Weighted schemes applied to 3D-OSEM reconstruction in PET

被引:0
|
作者
Michel, C [1 ]
Liu, X [1 ]
Sanabria, S [1 ]
Lonneux, M [1 ]
Sibomana, M [1 ]
Bol, A [1 ]
Comtat, C [1 ]
Kinahan, PE [1 ]
Townsend, DW [1 ]
Defrise, M [1 ]
机构
[1] Catholic Univ Louvain, PET Lab, B-3000 Louvain, Belgium
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to better preserve the Poisson characteristics of PET data when using 3D OSEM iterative reconstruction, we have compared images reconstructed by various data weighting schemes: unweighted, attenuation weighted, attenuation and normalization weighted OSEM 3D, FORE + unweighted and attenuation weighted OSEM 2D using 3DRP and FORE + FBP Images as reference. Due to better noise modeling, 3D weighted OSEM schemes are expected to produce better images (i.e, noise-bias trade-off) especially at low statistics, in short Frames of dynamic studies and when bed overlap is suboptimal, as in 3D wholebody studies. These reconstruction methods were implemented on the ECAT Exact HR and quantification was validated an clinical data. Their influence on physiological parameter measurements was examined on a dynamic brain receptor study with C-11-Flumazenil and a wholebody study with (18)FDG. The 3D weighted OSEM schemes provide unbiased results in volume of interests. The resulting noise reduction may lead to more accurate registration, acquisition of shorter frames and generation of parametric images.
引用
收藏
页码:1152 / 1157
页数:2
相关论文
共 50 条
  • [21] Investigation of the possibility of improving spatial resolution in SPECT with the combination of LaBr3:Ce-based detector and 3D-OSEM reconstruction algorithms
    Alzimami, Khalid S.
    Sassi, Salem A.
    Alfuraih, Abdulrahman A.
    Livieratos, Lefteris
    Spyrou, Nicholas M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S289 - S291
  • [22] Advancement in PET quantification using 3D-OP-OSEM PSF reconstruction with the HRRT
    Varrone, Andrea
    Sjoholm, N.
    Gulyas, B.
    Halldin, C.
    Farde, L.
    [J]. NEUROIMAGE, 2008, 41 : T85 - T85
  • [23] Performance characteristics of the 3-D OSEM algorithm in the reconstruction of small animal PET images
    Yao, RT
    Seidel, J
    Johnson, CA
    Daube-Witherspoon, ME
    Green, MV
    Carson, RE
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (08) : 798 - 804
  • [24] INTRA- AND INTER-ITERATION 3D OSEM PET IMAGE RECONSTRUCTION
    Jeng, Wei-Min
    Hsu, Yu-Liang
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2007, 19 (04): : 239 - 249
  • [25] 3D-OSEM and FP-CIT SPECT quantification: benefit for studies with a high radius of rotation?
    Koch, Walter
    Bartenstein, Peter
    la Fougere, Christian
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (10) : 971 - 977
  • [26] FORE(J)+OSEM2D versus OSEM3D reconstruction for large aperture rotating LSO panel detector PET prototype
    Michel, C
    Hamill, J
    Panin, V
    Conti, M
    Jones, J
    Kehren, F
    Casey, M
    Bendriem, B
    Byars, L
    Defrise, M
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1231 - 1235
  • [27] Image Noise Variance in 3D OSEM Reconstruction of Clinical Time-of-Flight PET
    Watson, Charles C.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1736 - 1739
  • [28] Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering
    Jacobson, M
    Levkovitz, R
    Ben-Tal, A
    Thielemans, K
    Spinks, T
    Belluzzo, D
    Pagani, E
    Bettinardi, V
    Gilardi, MC
    Zverovich, A
    Mitra, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2417 - 2439
  • [29] Clinical comparison of FDG PET image reconstruction by ordered subsets expectation maximization (OSEM) and sinogram rebinning with attenuation-weighted osem (AWOSEM).
    Valk, PE
    Rao, J
    Finley, BR
    Farboud, B
    Bruckbauer, T
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 199P - 199P
  • [30] Factors affecting the performance of the 3D OSEM algorithm in the reconstruction of small animal PET images.
    Yao, R
    Seidel, J
    Johnson, CA
    Daube-Witherspoon, ME
    Green, MV
    Carson, RE
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 300P - 300P