Advancement in PET quantification using 3D-OP-OSEM PSF reconstruction with the HRRT

被引:1
|
作者
Varrone, Andrea
Sjoholm, N.
Gulyas, B.
Halldin, C.
Farde, L.
机构
[1] Karolinska Inst, Psychiat Sect, Dept Clin Neurosci, Stockholm, Sweden
[2] Stockholm Brain Inst, Stockholm, Sweden
关键词
D O I
10.1016/j.neuroimage.2008.04.054
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
引用
收藏
页码:T85 / T85
页数:1
相关论文
共 50 条
  • [1] Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
    Varrone, Andrea
    Sjoholm, Nils
    Eriksson, Lars
    Gulyas, Balazs
    Halldin, Christer
    Farde, Lars
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (10) : 1639 - 1650
  • [2] Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
    Andrea Varrone
    Nils Sjöholm
    Lars Eriksson
    Balazs Gulyás
    Christer Halldin
    Lars Farde
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1639 - 1650
  • [3] Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
    Olesen, Oline Vinter
    Sibomana, Merence
    Keller, Sune Hogild
    Andersen, Flemming
    Jensen, Jorgen
    Holm, Soren
    Svarer, Claus
    Hojgaard, Liselotte
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3789 - 3790
  • [4] OSEM-3D reconstruction strategies for the ECAT HRRT
    Comtat, C
    Bataille, F
    Michel, C
    Jones, JP
    Sibomana, M
    Janeiro, L
    Trébossen, R
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3492 - 3496
  • [5] Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU
    Kim, Kyung Sang
    Ye, Jong Chul
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 4991 - 5009
  • [6] Accurate 3D reconstruction by a new PDS-OSEM algorithm for HRRT
    Chen, Tai-Been
    Lu, Henry Horng-Shing
    Kim, Hang-Keun
    Son, Young-Don
    Cho, Zang-Hee
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 96 : 107 - 114
  • [7] Comparison of 3-D reconstruction with 3D-OSEM and with FORE plus OSEM for PET
    Liu, X
    Comtat, C
    Michel, C
    Kinahan, P
    Defrise, M
    Townsend, D
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) : 804 - 814
  • [8] Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for High-Resolution Research Tomograph studies: effects of randoms estimation methods
    van Velden, Floris H. P.
    Kloet, Reina W.
    van Berckel, Bart N. M.
    Wolfensberger, Saskia P. A.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (12): : 3217 - 3230
  • [9] Weighted schemes applied to 3D-OSEM reconstruction in PET
    Michel, C
    Liu, X
    Sanabria, S
    Lonneux, M
    Sibomana, M
    Bol, A
    Comtat, C
    Kinahan, PE
    Townsend, DW
    Defrise, M
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1152 - 1157
  • [10] Simulation-based Evaluation of OSEM Reconstruction Bias on low activity PET Data for the HRRT scanner
    Dusch, Elodie
    Comtat, Claude
    Trebossen, Regine
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2770 - 2773