OSEM-3D reconstruction strategies for the ECAT HRRT

被引:0
|
作者
Comtat, C [1 ]
Bataille, F [1 ]
Michel, C [1 ]
Jones, JP [1 ]
Sibomana, M [1 ]
Janeiro, L [1 ]
Trébossen, R [1 ]
机构
[1] CEA, Frederic Joliot Hosp Facil, SHFJ, Orsay, France
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
High spatial resolution dynamic brain PET imaging with the ECAT HRRT scanner with short frame durations is characterized by very few counts per sinogram bin due to the small size of the crystal surface. The use of various weighting schemes for OSEM-3D can result in significantly different results. In particular, the correction for random and scattered coincidences prior to the reconstruction can lead to a systematic positive bias in the reconstructed image. We show that the use of Ordinary Poisson OSEM-3D, where all corrections are applied during the iterative steps, allows to avoid this bias without compromising spatial resolution, at a price of a lower convergence rate.
引用
收藏
页码:3492 / 3496
页数:5
相关论文
共 50 条
  • [1] Isotropic 3D-SPECT-Reconstruction Using OSEM-3D: Correlation with CT Data
    Roemer, W.
    Reichel, N.
    Nickel, I.
    Hornegger, J.
    Bautz, W.
    Kuwert, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S254 - S255
  • [2] Accurate 3D reconstruction by a new PDS-OSEM algorithm for HRRT
    Chen, Tai-Been
    Lu, Henry Horng-Shing
    Kim, Hang-Keun
    Son, Young-Don
    Cho, Zang-Hee
    RADIATION PHYSICS AND CHEMISTRY, 2014, 96 : 107 - 114
  • [3] Advancement in PET quantification using 3D-OP-OSEM PSF reconstruction with the HRRT
    Varrone, Andrea
    Sjoholm, N.
    Gulyas, B.
    Halldin, C.
    Farde, L.
    NEUROIMAGE, 2008, 41 : T85 - T85
  • [4] Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
    Olesen, Oline Vinter
    Sibomana, Merence
    Keller, Sune Hogild
    Andersen, Flemming
    Jensen, Jorgen
    Holm, Soren
    Svarer, Claus
    Hojgaard, Liselotte
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3789 - 3790
  • [5] An evaluation of half-dose imaging reconstructed with OSEM-3D
    Steckbauer, Kyle
    Leonard, Scott
    Riehle, Lisa
    Wu, Edwin
    Holly, Thomas
    Spies, Stewart
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] Randoms estimation for list-mode reconstruction for the ECAT HRRT
    Barker, WC
    Liow, JS
    Rodriguez, M
    Thada, S
    Iano-Fletcher, AR
    Lenox, M
    Michel, C
    Johnson, CA
    Carson, RE
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3510 - 3513
  • [7] An evaluation of half-dose imaging reconstructed with OSEM-3D
    Steckbauer, Kyle
    Leonard, Scott
    Riehle, Lisa
    Wu, Edwin
    Holly, Thomas
    Spies, Stewart
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
    Andrea Varrone
    Nils Sjöholm
    Lars Eriksson
    Balazs Gulyás
    Christer Halldin
    Lars Farde
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1639 - 1650
  • [9] Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
    Varrone, Andrea
    Sjoholm, Nils
    Eriksson, Lars
    Gulyas, Balazs
    Halldin, Christer
    Farde, Lars
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (10) : 1639 - 1650
  • [10] Comparison of 3D-RP and 3D-OPOSEM Reconstructions of the ECAT HRRT PET Data
    Tuna, Uygar
    Johansson, Jarkko
    Ruotsalainen, Ulla
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3511 - 3515