Comparison of 3D-RP and 3D-OPOSEM Reconstructions of the ECAT HRRT PET Data

被引:0
|
作者
Tuna, Uygar [1 ]
Johansson, Jarkko [2 ]
Ruotsalainen, Ulla [1 ,2 ]
机构
[1] Tampere Univ Technol, Dept Signal Proc, POB 533, FIN-33101 Tampere, Finland
[2] Turku Univ Hosp, Turku PET Ctr, Turku, Finland
基金
芬兰科学院;
关键词
binding potential image; gap filling; high resolution research tomograph (ECAT HRRT); time activity curve; positron emission tomography; quantitative evaluation; ROI; SINOGRAMS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Positron emission tomography (PET) is a powerful tool for quantifying the physiological processes through dynamic PET studies. In PET reconstruction, statistical image reconstruction methods such as ordered subset expectation maximization (OSEM) are widely used. However, it has been shown that iterative reconstruction methods produce bias for low count statistics data which is typical in dynamic PET studies. This bias problem has been published previously also for the ECAT high resolution research tomograph (HRRT, CTI PET Systems, Knoxville, TN, USA) PET scanner. Alternatively, dynamic PET data can be reconstructed analytically (for example by using 3D Reprojection, 3D-RP method). In this study, we compare 3D-RP and 3D-OPOSEM reconstructed dynamic HRRT PET images. For the 3D-RP reconstruction, the missing parts (caused by the octagonal detector design in the HRRT gantry) were estimated by the 3D DCT-domain gap-filling with a dedicated DCT-domain filter and the 3D transradial bicubic interpolation methods. We compared the reconstruction methods with two scans of one subject performed with the [C-11]-raclopride tracer. We assessed the methods visually by calculating the ratio images between the binding potential images obtained by different reconstruction methods. Moreover, regional time activity curves (TACs) and areas under the TACs of the employed reconstruction schemes were compared. We observed that for the cerebellum, caudate and putamen regions, 3D-RP reconstruction produced higher activity concentration than the 3D-OPOSEM reconstructions. On the other hand, the results obtained by the 3D-RP after different gap-filling methods were similar.
引用
收藏
页码:3511 / 3515
页数:5
相关论文
共 50 条
  • [1] OSEM-3D reconstruction strategies for the ECAT HRRT
    Comtat, C
    Bataille, F
    Michel, C
    Jones, JP
    Sibomana, M
    Janeiro, L
    Trébossen, R
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3492 - 3496
  • [2] 3D-RP: A DHT-based routing protocol for MANETs
    Shah, Nadir (nadirshah82@gmail.com), 1600, Oxford University Press (58):
  • [3] Comparison of FORE with 3DRP reconstructions for 3D PET
    Bai, Bing
    Mann, J. J.
    Parsey, R. V.
    NEUROIMAGE, 2008, 41 : T60 - T60
  • [4] 3D-RP: A DHT-Based Routing Protocol for MANETs
    Abid, S. A.
    Othman, Mazliza
    Shah, Nadir
    Ali, Mazhar
    Khan, A. R.
    COMPUTER JOURNAL, 2015, 58 (02): : 258 - 279
  • [5] Accuracy of CPU versus vector processor based reconstructions of 2D and 3D PET scans with the ECAT HR plus PET scanner
    Balen, SCM
    Boellaard, R
    Lammertsma, AA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1136 - 1136
  • [6] 3D PET reconstruction with the ECAT EXACT HR using Fourier rebinning
    Defrise, M
    Sibomana, M
    Michel, C
    Newport, D
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1316 - 1320
  • [7] 3D-ACQUISITION AND PROCESSING WITH THE ECAT
    NEWIGER, H
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1991, 17 (3-4) : 219 - 221
  • [8] Critical exponents and unusual properties of the broken phase in the 3d-RP(2) antiferromagnetic model.
    Ballesteros, HG
    Fernandez, LA
    MartinMayor, V
    Sudupe, AM
    NUCLEAR PHYSICS B, 1997, : 686 - 689
  • [9] Benefits of 3D Scatter Correction for the HRRT - a Large Axial FOV PET Scanner
    Sibomana, Merence
    Keller, Sune H.
    Stute, Simon
    Comtat, Claude
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2954 - 2957
  • [10] Advancement in PET quantification using 3D-OP-OSEM PSF reconstruction with the HRRT
    Varrone, Andrea
    Sjoholm, N.
    Gulyas, B.
    Halldin, C.
    Farde, L.
    NEUROIMAGE, 2008, 41 : T85 - T85