OSEM-3D reconstruction strategies for the ECAT HRRT

被引:0
|
作者
Comtat, C [1 ]
Bataille, F [1 ]
Michel, C [1 ]
Jones, JP [1 ]
Sibomana, M [1 ]
Janeiro, L [1 ]
Trébossen, R [1 ]
机构
[1] CEA, Frederic Joliot Hosp Facil, SHFJ, Orsay, France
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
High spatial resolution dynamic brain PET imaging with the ECAT HRRT scanner with short frame durations is characterized by very few counts per sinogram bin due to the small size of the crystal surface. The use of various weighting schemes for OSEM-3D can result in significantly different results. In particular, the correction for random and scattered coincidences prior to the reconstruction can lead to a systematic positive bias in the reconstructed image. We show that the use of Ordinary Poisson OSEM-3D, where all corrections are applied during the iterative steps, allows to avoid this bias without compromising spatial resolution, at a price of a lower convergence rate.
引用
收藏
页码:3492 / 3496
页数:5
相关论文
共 50 条
  • [31] Parallel OSEM reconstruction algorithm for fully 3-D SPECT on a beowulf cluster
    Zhou Rong
    Ma Tianyu
    Jin Yongjie
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1834 - 1837
  • [32] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [33] Isotropic reconstruction of SPECT data using OSEM3D:: Correlation with CT
    Römer, W
    Reichel, N
    Vija, HA
    Nickel, I
    Hornegger, J
    Bautz, W
    Kuwert, T
    ACADEMIC RADIOLOGY, 2006, 13 (04) : 496 - 502
  • [34] Parallelization and Runtime Prediction of the ListMode OSEM Algorithm for 3D PET Reconstruction
    Schellmann, Maraike
    Koesters, Thomas
    Gorlatch, Sergei
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2190 - 2195
  • [35] 3D-OSEM vs FORE plus OSEM: The optimal reconstruction algorithm in FDG PET tests with short acquisition time
    Tsuda, Keisuke
    Fukushi, Masahiro
    Hirayama, Akira
    Suzuki, Takayuki
    Toya, Kazuhito
    Koyama, Kazuya
    Iwabuchi, Yuto
    Nemoto, Koichi
    Moriyama, Noriyuki
    Fujii, Hirofumi
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [36] FORE(J)+OSEM2D versus OSEM3D reconstruction for large aperture rotating LSO panel detector PET prototype
    Michel, C
    Hamill, J
    Panin, V
    Conti, M
    Jones, J
    Kehren, F
    Casey, M
    Bendriem, B
    Byars, L
    Defrise, M
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1231 - 1235
  • [37] Ultrafast Preconditioned Conjugate Gradient OSEM Algorithm for Fully 3D PET Reconstruction
    Hong, I. K.
    Burbar, Z.
    Michel, C.
    Leahy, R.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2418 - +
  • [38] Experimental verification of 3D detector response compensation using the OSEM reconstruction method
    Blinder, S
    Celler, A
    Wells, RG
    Thomson, D
    Harrop, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2174 - 2178
  • [39] INTRA- AND INTER-ITERATION 3D OSEM PET IMAGE RECONSTRUCTION
    Jeng, Wei-Min
    Hsu, Yu-Liang
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2007, 19 (04): : 239 - 249
  • [40] Performance characteristics of the 3-D OSEM algorithm in the reconstruction of small animal PET images
    Yao, RT
    Seidel, J
    Johnson, CA
    Daube-Witherspoon, ME
    Green, MV
    Carson, RE
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (08) : 798 - 804