A method of overlap correction for fully 3D OSEM reconstruction of PET data

被引:0
|
作者
Ross, S [1 ]
Stearns, C [1 ]
Manjeshwar, R [1 ]
Iatrou, M [1 ]
机构
[1] GE Healthcare Technol, Waukesha, WI 53188 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In whole body PET studies, acquisitions are typically overlapped axially to improve the statistics of the slices at the edge of the field of view. This is particularly important in 3D acquisitions where the slice sensitivity profile varies more than in 2D acquisitions. 3D PET data in the overlapped region may be combined after reconstruction, by a weighted average of the corresponding images from the two frames, or the data may be combined after Fourier Rebinning is used to convert it to a stack of 2D transaxial sinograms. Direct combination of the 3D data on a frame by frame basis is difficult because many lines of response through the overlapped region also pass through the non-overlapped regions of image space. This paper describes a memory efficient method for combining overlapped 3D projection plane data in the loop of a fully 3D OSEM algorithm. In this method, a subset of 3D projection plane data is read from each frame and used to update the appropriate region of the ratio and correction images required in the iterative algorithm. The full 3D ratio and correction image volumes are then built for all frames for each subset. With each subset, the ratio and correction image volumes are used to create a new image estimate. This algorithm is compared to post reconstruction overlap correction using 3D OSEM on separate frames.
引用
收藏
页码:3497 / 3500
页数:4
相关论文
共 50 条
  • [1] Ultrafast Preconditioned Conjugate Gradient OSEM Algorithm for Fully 3D PET Reconstruction
    Hong, I. K.
    Burbar, Z.
    Michel, C.
    Leahy, R.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2418 - +
  • [2] An advanced fully 3D OSEM reconstruction for positron emission tomography
    贠明凯
    刘双全
    单保慈
    魏龙
    [J]. Chinese Physics C, 2010, 34 (02) : 231 - 236
  • [3] An advanced fully 3D OSEM reconstruction for positron emission tomography
    Yun Ming-Kai
    Liu Shuang-Quan
    Shan Bao-Ci
    Wei Long
    [J]. CHINESE PHYSICS C, 2010, 34 (02) : 231 - 236
  • [4] Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
    Rapisarda, E.
    Bettinardi, V.
    Thielemans, K.
    Gilardi, M. C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (14): : 4131 - 4151
  • [5] Fully 3D GPU PET reconstruction
    Herraiz, J. L.
    Espana, S.
    Cal-Gonzalez, J.
    Vaquero, J. J.
    Desco, M.
    Udias, J. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S169 - S171
  • [6] Parallelization and Runtime Prediction of the ListMode OSEM Algorithm for 3D PET Reconstruction
    Schellmann, Maraike
    Koesters, Thomas
    Gorlatch, Sergei
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2190 - 2195
  • [7] Comparison of 3-D reconstruction with 3D-OSEM and with FORE plus OSEM for PET
    Liu, X
    Comtat, C
    Michel, C
    Kinahan, P
    Defrise, M
    Townsend, D
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) : 804 - 814
  • [8] INTRA- AND INTER-ITERATION 3D OSEM PET IMAGE RECONSTRUCTION
    Jeng, Wei-Min
    Hsu, Yu-Liang
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2007, 19 (04): : 239 - 249
  • [9] Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU
    Kim, Kyung Sang
    Ye, Jong Chul
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 4991 - 5009
  • [10] Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: Phantom studies
    Vija, AH
    Hawman, EG
    Engdahl, JC
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2662 - 2666